C-Tec BF320JP XLR Connector Plate for BF320 C-Tec BF320JP XLR Connector Plate for BF320The BF320JP can be used in conjunction with a BF320 vibrating pillow pad to warn the hearing impaired of a potential fire alarm or evacuation alert condition. It is compatible with all C-TEC fire alarm and evacuation alert systems.Key FeaturesLocking mini-XLR connector and plug arrangement helps prevent accidental pillow pad removalLine monitored for disconnection via an internal 6k8 end of line resistor selectable at the BF320JPSelectable 6K8 pillow pad or 27K jack socket end of line monitoring options for fire alarm or evacuation alert system useCan be used on systems with a 10-30V DC voltage rangeFits on a standard UK 25mm back boxSupersedes the old BF364 jack socket GBP 19.32 1
C-Tec BF320 24V BS 5446-3 Vibrating Pillow Pad C-Tec BF320 24V BS 5446-3 Vibrating Pillow PadCan be used in conjunction with a BF320JP connection plate to warn the hearing impaired of a potential fire alarm or evacuation alert condition. Vibrates and pulses on and off when triggered as per the requirements of BS 5446-3 2015. Designed to be placed under a pillow to supplement the audible andor visual indication alerts provided by a systems sounders andor VADs. Wide10-30V DC voltage range means it can also be connected to many third-party connector plates subject to testing. Includes a 2m connection lead with a locking mini-XLR connector to prevent accidental removal. Includes a 6K8 end-of-line monitoring resistor for fire alarm system use - see instructions for monitoring options on other systems. Supersedes our old BF363 pillow pad.Key FeaturesCan be used in conjunction with aBF320JP connection plateto warnthe hearing impaired of a potential fire alarm or evacuation alert condition.Vibrates and pulses on and off when triggered as per the requirements of BS 5446-3 2015.Designed to be placed under a pillow to supplement the audible andor visual indication alertsprovided by a systems sounders andor VADs.Wide10-30V DC voltagerange means it can also be connected tomanythird-party connector plates subject to testing.Includes a 2m connection lead with a locking mini-XLR connector to prevent accidental removal.Includes a 6K8 end-of-line monitoring resistor for fire alarm system use - see instructions for monitoring options on other systems.Supersedes our old BF363 pillow pad. GBP 24.16 1
C-Tec CA454AW CA Base Voice Sounder - White C-Tec CA454AW CA Base Voice Sounder - WhiteCAST is the worlds most-advanced distributedintelligence fire alarm system protocol. Conceived designed and realised byC-TEC as part of a five-year multi-million pound project it involved thecreation of a powerful proprietary communication protocol C-TEC AddressableSystem Technology CAST and multiple control panels field devices.Key FeaturesSuperb sound intelligibilityOnboard short-circuit loop isolatorFour selectable volume levelsSix selectable messages with tones 2 evacuate 1 alert 1all clear 2 system test messages15.5mA typical alarm current 470A typical quiescentcurrent 24-40V DC max volume brightnessGroup addressing facility allows multiple devices to beoperated simultaneouslyOptional BF330CTLIDW white or BF330CTLIDR red cap availablefor stand-alone useIP21C ratedWhite ceiling fixing plate detector spur wiresincluded GBP 43.63 1
C-Tec BF430CCCDR65 ActiV Conventional Weatherproof Wall Sounder with Deep Base C-Tec BF430CCCDR65 ActiV Conventional Weatherproof Wall Sounder with Deep BaseThe ActiV Hi-Output range of conventional sounders and combined sounder visual alarm devices VADs are designed for use with C-TECs range of fire panels and other compatible third-party panels. However compatibility testing with third-party panels is recommended to ensure correct operation. With a 100 dBA peak sound output 1 m their purpose is to visually and audibly alert building occupants of a fire alarm. Units are supplied with either a shallow or deep base in a red plastic enclosure.The devices offer low current consumption high sound output 31 selectable primary tones with selectable secondary tone set and two selectable volume levels. Tones and volume levels are changed using the devices 8-way DIP switch.Key FeaturesLPCB certified to EN54-3 SoundersImpressive 100dBA sound output 1m31 selectable primary andsecondary tone pairs and two volume levels high and lowAlarm Current at 30Vdc 5.5mAAlarm Current at 18Vdc 3.8mAIP55C rated weatherproofManufactured in the UK by C-TEC GBP 22.63 1
C-Tec BF430CCCDR ActiV Conventional Wall Sounder with Deep Base C-Tec BF430CCCDR ActiV Conventional Wall Sounder with Deep BaseThe ActiV Hi-Output range of conventional sounders and combined sounder visual alarm devices VADs are designed for use with C-TECs range of fire panels and other compatible third-party panels. However compatibility testing with third-party panels is recommended to ensure correct operation. With a 100 dBA peak sound output 1 m their purpose is to visually and audibly alert building occupants of a fire alarm. Units are supplied with either a shallow or deep base in a red plastic enclosure.The devices offer low current consumption high sound output 31 selectable primary tones with selectable secondary tone set and two selectable volume levels. Tones and volume levels are changed using the devices 8-way DIP switch.Key FeaturesLPCB certified to EN54-3 Sounders and EN54-23 VADsImpressive 100dBA sound output 1m31 selectable primary andsecondary tone pairs and two volume levels high and lowAlarm Current at 30Vdc 5.5mAAlarm Current at 18Vdc 3.8mAIP33C ratedManufactured in the UK by C-TEC GBP 18.18 1
C-Tec BF330CT 24V Loop Sounder Base White C-Tec BF330CT 24V Loop Sounder Base WhiteThe BF330CR is designed for use with Apollo XP95 Series 90Xplorer andor Discovery compatible fire alarm control panels. It can be usedas an interior surface mountable stand-alone unit using a separately availablewhite or red cap or as part of an interior sounderdetectorbase combinationwith a compatible detectorbase mounted upon it. For stand-alone use use aBF330CRLIDR red cap or a BF330CRLIDW white cap. For combination use note thatthe sounders volume address and tone controls will be obscured once thedetector is in position. Ensure these are set prior to installation.Key FeaturesStraightforward DIL switch addressingDesigned for use as part of a sounderdetector basecombination - requires a separately available smokeheat detector and detectorbaseCan also be used as a stand-alone unit - requires aseparately available lockable white cap part no. BF330CRLIDW or red cap partno. BF330CRLIDRVolume adjustable downwards from 91dBA800 quiescent current7mA typical alarm current 24VThree link selectable alarm tones continuous warble orsweep and one Alert toneCan be set to operatein master or shadow mode multiple shadow sounders can be given the same IDaddress as one master sounder - ideal for use on heavily populated systemsIP42 ratedDimensions 106mm diameter x 25mm deep 35mmwith optional cap fitted GBP 33.28 1
C-Tec BF433CCCDR ActiV Conventional Wall Sounder VAD with Deep Base C-Tec BF433CCCDR ActiV Conventional Wall Sounder VAD with Deep BaseThe ActiV Hi-Output range of conventional sounders and combined sounder visual alarm devices VADs are designed for use with C-TECs range of fire panels and other compatible third-party panels. However compatibility testing with third-party panels is recommended to ensure correct operation. With a 100 dBA peak sound output 1 m their purpose is to visually and audibly alert building occupants of a fire alarm. Units are supplied with either a shallow or deep base in a red plastic enclosure.The devices offer low current consumption high sound output high efficiency VADs 31 selectable primary tones with selectable secondary tone set two selectable volume levels and three selectable VAD flash rates. Tones volume levels and VAD flash rates are changed using the devices 8-way DIP switch.Key FeaturesLPCB certified to EN54-3 Sounders and EN54-23 VADsProvides W-2.75-9 rated light distribution when wall mounted min. 0.4 lux over a 2.75x 9m cuboid area. Also rated as a W-4-4 VADImpressive 100dBA sound output 1m31 selectable primary andsecondary tone pairs and two volume levels high and lowThree selectable VAD flash rates 0.5Hz 1Hz OFFAlarm Current at 30Vdc 12.2mA 0.5Hz or 19.5mA 1HzAlarm Current at 18Vdc 14.5mA 0.5Hz or 25mA 1HzIP33C ratedManufactured in the UK by C-TEC GBP 42.67 1
C-Tec BF433CCCSR ActiV Conventional Wall Sounder VAD with Shallow Base C-Tec BF433CCCSR ActiV Conventional Wall Sounder VAD with Shallow BaseThe ActiV Hi-Output range of conventional sounders and combined sounder visual alarm devices VADs are designed for use with C-TECs range of fire panels and other compatible third-party panels. However compatibility testing with third-party panels is recommended to ensure correct operation. With a 100 dBA peak sound output 1 m their purpose is to visually and audibly alert building occupants of a fire alarm. Units are supplied with either a shallow or deep base in a red plastic enclosure.The devices offer low current consumption high sound output high efficiency VADs 31 selectable primary tones with selectable secondary tone set two selectable volume levels and three selectable VAD flash rates. Tones volume levels and VAD flash rates are changed using the devices 8-way DIP switch.Key FeaturesLPCB certified to EN54-3 Sounders and EN54-23 VADsProvides W-2.75-9 rated light distribution when wall mounted min. 0.4 lux over a 2.75x 9m cuboid area. Also rated as a W-4-4 VADImpressive 100dBA sound output 1m31 selectable primary andsecondary tone pairs and two volume levels high and lowThree selectable VAD flash rates 0.5Hz 1Hz OFFAlarm Current at 30Vdc 12.2mA 0.5Hz or 19.5mA 1HzAlarm Current at 18Vdc 14.5mA 0.5Hz or 25mA 1HzIP21C ratedManufactured in the UK by C-TEC GBP 41.16 1
C-Tec BF432CCCW ActiV Conventional Base Sounder VAD O-R-3-2.5-17 C-Tec BF432CCCW ActiV Conventional Base Sounder VAD O-R-3-2.5-17The ActiV Base Mount range of conventional sounders and combined sounder visual alarm devices VADs are designed for use with C-TECs range of fire panels and other compatible third-party panels. However compatibility testing with third-party panels is recommended to ensure correct operation. Their purpose is to visually and audibly alert building occupants of a fire alarm.The bases offer low current consumption high sound output high efficiency VADs 31 selectable primary tones with selectable secondary tone set two selectable volume levels and three selectable VAD flash rates. Tones volume levels and VAD flash rates are changed using the bases 8-way DIP switch.All bases can be optionally used as eithera stand-alone base device using a separately available locking white cap BF330CTLIDW red cap BF330CTLIDR ora combined base device and detector detectors are separately available and wired on a separate detection circuit. The base devices are compatible with C-TECs range of ActiV conventional detectors and other compatible third-party suppliers.Key FeaturesThird-party certified to EN54-3 SoundersandEN54-23 VADsProvides O-R-3-2.5-17 light distributionIdeally suited for use in corridors and other rectangular areasImpressive 96dBA sound output 1m31 selectable primary andsecondary tone pairs and two volume levels high and lowThree selectable VAD flash rates 0.5Hz 1Hz OFFAlarm Current at 30Vdc 12.2mA 0.5Hz or 19.5mA 1HzAlarm Current at 18Vdc 14.5mA 0.5Hz or 25mA 1HzOptional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone useSupplied with a BF431QCP quick connect plate and detector spur wiresIP21C rated GBP 39.78 1
C-Tec BF460ACXW Addressable Base VAD C-3-8 C-Tec BF460ACXW Addressable Base VAD C-3-8The C-Tec BF460ACXW is an addressable VAD beacon base which is ideal for use with the Apollo protocol range of C-Tec XFP and ZFP fire alarm control panels.The Base Mount range of addressable loop-powered bases includes sounders visual alarm devices VADs and combined sounder VADs. They are designed for use with C-TECs ZFPXFP panels and other Apollo Discovery compatible fire panels.Their purpose is to visually and audibly alert building occupants of a fire alarm.All bases can be optionally used as eithera stand-alone base using a separately available locking white cap BF330CTLIDW red cap BF330CTLIDR ora combined base and Apollo detector Apollo detectors are separately available.The bases offer low current consumption high sound output high efficiency VADs seven selectable volume levels 15 selectable tone pairs and built-in short-circuit loop isolators. The combined sounder and VAD on the BF432ACXW and BF456ACXW bases can be set to operate independently of each other panel dependent function.All bases excluding BF432ACXW and BF459ACXW are fully certified with all relevant sections of the fire alarm device standards EN 54-3 Sounders EN 54-23 Visual alarm devices - VADs and EN 54-17 Short-circuit isolators.Key FeaturesProvides C-3-8 light distribution min 0.4 lux over a 3 x 8m cylindrical areaSupplied with a BF431QCP quick connect plate and detector spur wiresOnboard short-circuit loop isolator550A quiescent current10mA alarm current 24V DCGroup addressing facility allows multiple devices to be operated simultaneouslyOptional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone useIP21C rated GBP 33.95 1
C-Tec BF456CCCW ActiV Conventional Base Sounder VAD C-3-8.5 C-Tec BF456CCCW ActiV Conventional Base Sounder VAD C-3-8.5The ActiV Base Mount range of conventional sounders and combined sounder visual alarm devices VADs are designed for use with C-TECs range of fire panels and other compatible third-party panels. However compatibility testing with third-party panels is recommended to ensure correct operation. Their purpose is to visually and audibly alert building occupants of a fire alarm.The BF456CCCW base sounder VAD offer low current consumption high sound output high efficiency VADs 31 selectable primary tones with selectable secondary tone set two selectable volume levels and three selectable VAD flash rates. Tones volume levels and VAD flash rates are changed using the bases 8-way DIP switch.All bases can be optionally used as eithera stand-alone base device using a separately available locking white cap BF330CTLIDW red cap BF330CTLIDR ora combined base device and detector detectors are separately available and wired on a separate detection circuit. The base devices are compatible with C-TECs range of ActiV conventional detectors and other compatible third-party suppliers.Key FeaturesThird-party certified to EN54-3 SoundersandEN54-23 VADsProvides C-3-8.5 light distribution min 0.4 lux over a 3 x 8.5m cylindrical areaImpressive 96dBA sound output 1m31 selectable primary andsecondary tone pairs and two volume levels high and lowThree selectable VAD flash rates 0.5Hz 1Hz OFFAlarm Current at 30Vdc 12.2mA 0.5Hz or 19.5mA 1HzAlarm Current at 18Vdc 14.5mA 0.5Hz or 25mA 1HzOptional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone useSupplied with a BF431QCP quick connect plate and detector spur wiresIP21C rated GBP 39.78 1
C-Tec BF458ACXSW Addressable Ceiling VAD C-Tec BF458ACXSW Addressable Ceiling VADThe C-TEC BF458ACXSW is a compact addressable loop-powered wall VAD in white. It provides W-3-3.1 light distribution when wall mounted min 0.4 lux over a 3 x 8m cylindrical area or it can also provide C-3-8 light distribution when ceiling mounted min 0.4 lux over a 2.4 x 3.5m cuboid area. It is compatible with XP95Discovery protocol systems and designed for use with C-TECs XFP and ZFP fire panels.The Compact range of addressable loop powered devices include sounders visual alarm devices VADs and combined sounder VADs. They are designed for indoor use with C-TECs ZFPXFP and other Apollo Discovery compatible fire panels.Their purpose is to visually and audibly alert building occupants of a fire alarm. The devices offer low current consumption high sound output high efficiency VADs seven selectable volume levels 15 selectable tone pairs and built-in short-circuit loop isolators.The sounder and VAD on the combined device can be set to operate independently of each other panel dependent function.All devices are fully compliant with the relevant sections of the fire alarm device standards EN 54-3 Sounders EN 54-23 Visual alarm devices - VADs and EN 54-17 Short-circuit isolators.Key FeaturesThird-party certified to EN54-23 VADs and 17 Isolators by IntertekProvides C-3-8 light distribution when ceiling mounted min 0.4 lux over a 3 x 8m cylindrical areaCan also provide W-3-3.1 light distribution when wall mounted min. 0.4 lux over a 2.4 x 3.5m cuboid areaOnboard short-circuit loop isolator550A quiescent current10mA alarm current 24V DCGroup addressing facility allows multiple devices to be operated simultaneouslyIP21C rated GBP 43.06 1