C-Tec CA736 EACIE 1 Way Flat Interface - Double Gang C-Tec CA736 EACIE 1 Way Flat Interface - Double GangA loop-powered single way flat interface for use on a C-TEC EVAC-ALERT system which can control one or more evacuation alert devices located inside a flat.Key FeaturesReliable hard-wired technologyCompatible with the self-test facility on C-TECs BF430EA and BF433CEA range of self-testing evacuation alert devicesProvides one open short circuit fault monitored conventional sounder circuit faults are indicated on the CA736 and reported back to the host EVAC-ALERT panelMounts on a standard UK 35mm double gang back box outside the flat for BS 8629 Clause 8 compliance50mA alarm current can power up to 8 evacuation alert sounders most sites require only one alert sounder so this allows additional alert devices to be connected e.g. for the hard of hearingPolling Sounder Circuit Active and Input Fault indicatorsOn-board short circuit loop isolator GBP 118.24 1
C-Tec BF433CEASW Wall Sounder VID - Self Testing - White C-Tec BF433CEASW Wall Sounder VID - Self Testing - WhiteThe BF433CEASW is a new EN54-3 compliant evacuation alert system from C-TEC specifically designed to assist the fire rescue services FRS in evacuating high-rise residential buildings. The device offers low current consumption emitting a clear concise and recognisable evacuation alarm toneDetailsDesigned for use on a C-TEC CAST-powered EVAC-ALERT system.Provides audible and visual indication of an evacuation alert to help satisfy the requirements of the Equality Act.Impressive 100dBA sound output at 1m.Low 12.2mA alarm current at 0.5Hz with sounder on max and indicator lit.IP21C rated.Designed to comply with EN54-3. GBP 131.30 1
C-Tec BF433CEASR Wall Sounder VID - Self Testing - Red C-Tec BF433CEASR Wall Sounder VID - Self Testing - RedThe is BF433CEASR a new EN54-3 compliant evacuation alert system from C-TEC specifically designed to assist the fire rescue services FRS in evacuating high-rise residential buildings. The device offers low current consumption emitting a clear concise and recognisable evacuation alarm tone.Details Designed for use on a C-TEC CAST-powered EVAC-ALERT system Provides audible and visual indication of an evacuation alert to help satisfy the requirements of the Equality Act Impressive 100dBA sound output at 1m Low 12.2mA alarm current at 0.5Hz with sounder on max and indicator lit IP21C rated. Designed to comply with EN54-3 White version also available order code BF433CEASW GBP 131.30 1
C-Tec BF447ACXDRLD CX Wall Voice Sounder VAD Deep Base - Red Lockdown C-Tec BF447ACXDRLD CX Wall Voice Sounder VAD Deep Base - RedLockdownThe Hi-Output range of addressableloop-powered devices include voice sounders and combined voice sounder VADs.Their purpose is to visually and audibly alert building occupants of a firealarm. They are designed for use with C-TECs ZFP and XFP Apollo Discoverypanels and other third-party Apollo Discovery panels. However compatibilitytesting with third-party panels is recommended to ensure correct operation.Pleasenote this image is for illustrative purposes only GBP 101.59 1
C-Tec CFP 4 Zone Conventional Fire Panel LPCB Approved - CFP704-4 C-Tec CFP 4 Zone Conventional Fire Panel LPCB Approved - CFP704-4LPCB certified to EN54-24 C-TECs CFP 4 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price. Supplied in an attractive flush or surface mountable plastic enclosure it includes two detector zones four conventional sounder circuits class change and alert inputs on-board fire and fault relays and combined keypadkey switch entry.A wide range of engineering functions are also provided including selectable zone delays coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided. Optional repeaters relay expansion boards and EN54-13 system compliance devices are also available.Key FeaturesThird-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board LPCB with optional EN54 part 13 compliance from the BSI.Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry.Manufactured by C-TEC in the UK.Two detector zone circuits.Four conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSU.Wide range of engineering functions including zone test coincidence zone delay and non-latching zones.Two on-board relays Fire and Fault.Two open-collector outputs Remote and Reset.Class change and alert inputs.Installer-friendly design.Attractive flush or surface mountable plastic lid and enclosure - no bezel required.Low 25mA quiescent current.Multiple indicators.System expansion connections provided for up to eight two-wire repeaters one CFP761 network card required per system optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.Space for two x 12V 3.3Ah VRLA batteries.Fully compatible with C-TECs ActiV range of conventional fire detectors. GBP 148.46 1
C-Tec CFP702-4 2 Zone Conventional Fire Panel LPCB Approved C-Tec CFP 2 Zone Conventional Fire Panel LPCB Approved - CFP702-4LPCB certified to EN54-24 C-TECs CFP 2 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price. Supplied in an attractive flush or surface mountable plastic enclosure it includes two detector zones four conventional sounder circuits class change and alert inputs on-board fire and fault relays and combined keypadkey switch entry.A wide range of engineering functions are also provided including selectable zone delays coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided. Optional repeaters relay expansion boards and EN54-13 system compliance devices are also available.Key FeaturesThird-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board LPCB with optional EN54 part 13 compliance from the BSI.Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry.Manufactured by C-TEC in the UK.Two detector zone circuits.Four conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSU.Wide range of engineering functions including zone test coincidence zone delay and non-latching zones.Two on-board relays Fire and Fault.Two open-collector outputs Remote and Reset.Class change and alert inputs.Installer-friendly design.Attractive flush or surface mountable plastic lid and enclosure - no bezel required.Low 25mA quiescent current.Multiple indicators.System expansion connections provided for up to eight two-wire repeaters one CFP761 network card required per system optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.Space for two x 12V 3.3Ah VRLA batteries.Fully compatible with C-TECs ActiV range of conventional fire detectors. GBP 130.25 1
C-Tec CP414V CAST-PRO Smoke Heat Multisensor cw Voice Sounder C-Tec CP414V CAST-PRO Smoke Heat Multisensor cw VoiceSounderA multiple functionality in a single device smoke heat multisensor fire detection plus an 86dbA voice sounder detects realfires quickly reduces false alarms effectively and indicates true alarmconditions decisively.Key FeaturesCertified to EN54-3 5 7 17 29.Compatible with C-TECs ZFPtouchscreen-controlled CAST protocol addressable fire panel.MASC Miniature Advanced Smoke DetectionChamber and AFFIRM algorithms provide incredible tolerance to false alarmswhilst enhancing the detection of real fire conditions.Drift compensation functionality.Onboard short circuit loop isolator.Includes two 8mm x 2mm ultra-bright red LEDindicating strips.Multiple detection modes and differentsensitivities for different times of the day.Six selectable voice messages with tones 2evacuate 1 alert 1 all clear 2 system test messages.17.1mA max. alarm current max vol VAD on.590uA typical quiescent current 40V DC.Compatible with C-TECs CA408 CAST base cwintegrated locking mechanism ID tag. GBP 110.68 1
C-Tec QT644 Floor Pressure Mat C-Tec QT644 Floor Pressure MatThe QT644 floor pressure mat is designed to alert staff to the prospect of a wandering patient in nursing homes hospitals and other care facilities. Fully compatible with our Quantec and 800 Series call systems the mat is manufactured to a high standard with an attractive grey PVC finish and non-slip rubber base.Key FeaturesDesigned to trigger a call when it detects patient foot pressureTypically located alongside a bed to advise staff of wandering patientsCan be connected to a Quantec addressable call system or an 800 Series conventional call system via a remote jack socketTough durable grey PVC finish with a non-slip rubber baseAttractive high-quality design - ideal for use in all types of care facilityCan be wiped-clean using a non-caustic sanitising solutionMeasures 90cm x 60cm 3ft x 2ft. Approx 5mm deepSupplied with a 2m lead and a normally open right-angled jack plugHelps protect infirm residents and dementia sufferers against potential falls by quickly alerting staff if someone gets out of bedHighly sensitiveSimple and reliable operationCan also be used in low-level access control applicationsExcellent discounts for quantity orders GBP 112.04 1