C-Tec ML1K ML1 Hearing Loop System C-Tec ML1K ML1 Hearing Loop SystemThe ML1K Hearing Loop System can be interfaced to a Type B outstations loop connectors to assist hearing aid users in an emergency situation.Key FeaturesIdeal for banks post offices small meeting rooms reception desks ticket booths and any other application requiring restricted or small area coverageRequires no specialist audio experience or connectors - can be fitted by any competent electricianSpace-saving double-gang wall-mounting amplifier fits standard UK 25mm back boxes requires fixed mains wiringOmni-directional AMT microphone supplied plugs directly into the 3.5mm socket on the amplifiers frontLineoutreach socket also provided max 3 outreach plates per systemUser-adjustable mic. sensitivity and engineer-adjustable loop drive and input level controls GBP 130.92 1
C-Tec 100m x 1.0mm2 Single Core White Loop Cable LOOP2W C-Tec 100m x 1.0mm2 Single Core White Loop Cable LOOP2WA 100m reel of white 1.0mm2 single core cable ideal for use as a floor or ceiling loop in audio-frequency induction loop systems. GBP 174.23 1
C-Tec CL1 Mini-Counter Hearing Loop Amplifier Only C-Tec CL1 Mini-Counter Hearing Loop Amplifier OnlyThe CL1 is a Mini-Counter Hearing Loop Amplifier Unit Only.A hearing loop systems allow hearing impaired people to hear more clearly. Most hearing aids have a T or MT switch which allows them to pick up the electromagnetic field generated by a hearing loop system. The hearing aid converts this signal into a sound suited to its users specific hearing requirements.Any person with a hearing aid positioned within or near the loop can hear the loop signal by switching their hearing aid to the correct position allowing them to participate more effectively in general conversation ordering goods or services listening to public performances etc.Key FeaturesIdeal for banks post offices small meeting rooms reception desks ticket booths and any other application requiring restricted or small area coverageMetal compensation control helps combat the frequency response problems caused by metal absorbing the magnetic field GBP 140.53 1
C-Tec ML1 PDA ML1 Counter Hearing Loop C-Tec ML1 PDA ML1 Counter Hearing LoopA PDA ML1 Counter Hearing Loop. GBP 111.26 1
C-Tec VL1 PDA 1.2m2 12V Vehicle Hearing Loop C-Tec VL1 PDA 1.2m2 12V Vehicle Hearing LoopThe VL1 12V Vehicle Hearing Loop is ideal for cars taxis buses and other privatecommercial vehicles.Key FeaturesLoop can be positioned in the vehicles roof lining under a seat across the back of a seat or in a door panel to suit the applicationMetal compensation control helps combat the frequency response problems caused by metal absorbing the magnetic field GBP 156.78 1
C-Tec CA740 Cast 4w Conventional Zone Convertor - No PSU Included C-Tec CA740 Cast 4w Conventional Zone Convertor - No PSU IncludedFacilitates the conversion and upgrade of a multi-zone conventional fire alarm system to an addressable CAST system utilising the conventional systems pre-existing zonal wiring.Four individual zonal circuits accommodate CAST addressable devices on separate isolated circuits. Supplied as a 4 zone loop powered unit extendable to 8 zones using a CA740PCB extender PCB the extra PCB is housed in the same enclosure but is allocated a separate loop address by the CIE.Fully complies with the requirements of BS 5839-1 and eliminates the need to provide extra wiring to extend loops while maintaining loop and individual zone circuit integrityIdeal for use on retrofit sites such as nursing homes where conventional devices are being replaced in situ with addressable devices and the existing wiring needs to be retained.Key FeaturesMaintains loop and individual zone circuit integrityPlastic enclosure provides ample space to connect loop and zone cablingNo end-of-line devices PSU or batteries required GBP 112.44 1
C-Tec CA739 CAST 4 Way Sounder Controller Extendable To 8 Way ZFP ONLY C-Tec CA739 CAST 4 Way Sounder Controller Extendable To 8Way ZFP ONLYA 4-8 way sounder controller specifically designed for useon a C-TEC CAST ZFP addressable fire alarm system.Compatible with C-TECs CAST ZFP Addressable Fire Panels.This device is NOT compatible with CAST XFP panels.Key FeaturesSupplied as a 4 circuit unit extendable to 8 circuits usinga CA739PCBProvides 4 or 8 monitored 12.5mA sounder circuitsIncludes space and connections for an optional fullymonitored auxiliary 24V 1.5A CA739PSU to power additional devicesIncludes an onboard short circuit loop isolatorUses one loop address per 4 sounder circuits12.5mA per sounder circuit capacity when loop powered 300mAper sounder circuit capacity when aux CA739PSU PSU is usedMaintains the independent open short circuitmonitoring of all sounder circuits GBP 171.24 1
C-Tec CA736 EACIE 1 Way Flat Interface - Double Gang C-Tec CA736 EACIE 1 Way Flat Interface - Double GangA loop-powered single way flat interface for use on a C-TEC EVAC-ALERT system which can control one or more evacuation alert devices located inside a flat.Key FeaturesReliable hard-wired technologyCompatible with the self-test facility on C-TECs BF430EA and BF433CEA range of self-testing evacuation alert devicesProvides one open short circuit fault monitored conventional sounder circuit faults are indicated on the CA736 and reported back to the host EVAC-ALERT panelMounts on a standard UK 35mm double gang back box outside the flat for BS 8629 Clause 8 compliance50mA alarm current can power up to 8 evacuation alert sounders most sites require only one alert sounder so this allows additional alert devices to be connected e.g. for the hard of hearingPolling Sounder Circuit Active and Input Fault indicatorsOn-board short circuit loop isolator GBP 118.24 1
C-Tec APXMM Mini-Mixer Plate C-Tec APXMM Mini-Mixer PlateThe Outreach Plate audio input extension system comprises a range of wall ceiling and desk mountable plates specifically designed to increase the audio input capability of any audio system. Covering the most common variants of audio connectors they work by mixing the signals from various audio input sources into a single balanced line level input on a compatible amplifier. Each input plate features a built-in mixer preamp input level control and balanced output.Typically up to 10Outreach plates any mix can be daisy-chained to one balanced line level connection with cable lengths up to 100m easily achievable using standard two-pair audio cable i.e. Belden 8723. Each plate requires four wires two balanced line LineA LineA one ground GND and one power connection V 12-32V d.c..Most of C-TECs PDA Range induction loop amplifiers are fitted with an Outreach connection socket as standard. For audio systems that do not have an Outreach socket straightforward network connection can be achieved using an APV 24V 250mA d.c. regulated power supply and an APXO 3 pin XLR balanced line output plate.Key FeaturesCombines the functions of anAPXM microphone Outreach plate and an APL dual phono Outreachplate in one double gang device.Accepts balanced or unbalanced microphones with standard 3 pin XLR connectors AND dual phono line level inputs.Gives a more attractive appearance than separate side-by-side single gang Outreach Plates.Counts as one of the total of ten plates permitted aspart of C-TECs patented Outreach Plate audio input extension system.Compatible with C-TECs entire range of PDA102 200E Pro-Rangeand ML1 induction loop amplifiers.Can be connected to any third-party audio or induction loop amplifier using an APV 24V 250mA power supply.Mounts on a 25mm standard UK doublegang back box. GBP 96.35 1
C-Tec AFP711 XFP Network Communications Card C-Tec AFP711 XFP Network Communications CardAn optional system expansion device for use with XFP 12 Loop 32 Zone fire panels. Allowsthe connection of up to eight XFP Repeaters or eight XFP Main panels any mix on an RS485 network. One AFP711 card required per networked Main XFP 12 Loop 32 Zone panel note that XFP510-16 and XFP510-32 repeaters include a network driver card as standard.The AFP711 is NOT compatible with XFP Single Loop 16 Zone panels which require a CFP761 card for networking.Key network protocol features when used for interconnecting XFP main panelsCan be used to connect up to 8 XFP main panels any mix over a two-wire RS485 network of up to 1KM in length.Each networked XFP can be programmed to accept Fires Faults and Control actions such as Silence Alarm Sounders and Control Panel Resets from other panels.Each XFP will accept Disablement commands for zones sounders and output sets from other panels.All panels monitored for network wiring faults.Fires and faults on remote panels are displayed on local panels including the point description.CEs can be programmed into local panels dependent on which remote panel is in alarm.The network supports the programming of site data into remote panels from a PC at a local panel.Time and date is common to all panels.All networked main panels require a network communication card.It is not possible to mix XFP main panels and XFP repeaters on the same network.Key network protocol features when used for connecting XFP repeatersCan be used to connect up to 8 XFP repeaters any mix to one XFP main panel.Up to 500m of cable may be fitted to an XFP two-wire repeater network.Each XFP repeater offers all the functions and controls of an XFP main panel.The XFP main panel must have a network communication card fitted.It is not possible to mix XFP main panels and XFP repeaters on the same network. GBP 114.65 1
C-Tec CA447ADR65 CA Wall Voice Sounder VAD Deep Red - IP5565 C-Tec CA447ADR65 CA Wall Voice Sounder VAD Deep Red - IP5565CAST is the worlds most-advanced distributedintelligence fire alarm system protocol. Conceived designed and realised byC-TEC as part of a five-year multi-million-pound project it involved thecreation of a powerful proprietary communication protocol C-TEC AddressableSystem Technology CAST and multiple control panels field devices.Key FeaturesSuperb sound intelligibilityOnboard short-circuit loop isolatorFour selectable volume levelsSix selectable messages with tonesProvides W-2.75-9 or W-4-4 rated light distribution26.5mA typical alarm current 470A typical quiescentcurrent 27-40V DCGroup addressing facility allows multiple devices to beoperated simultaneouslyIP5565 rated GBP 113.75 1
C-Tec BF447ACXSR Addressable Wall Voice Sounder VAD with Shallow Base C-Tec BF447ACXSR Addressable Wall Voice Sounder VAD with Shallow BaseThe BF447ACXSR is a Hi-Output wall VAD with voice sounder which has been designed with superb sound intelligibility for use with the C-Tec addressable range of control panels.Key FeaturesIncludes three selectable voice message pairsProvides W-2.4-8.2 light distribution when wallmounted min 0.4 lux over a 2.4m x8.2mcuboidarea using the same lens and electronics as our EN54-23 3 17 certified Wall Sounder VADOnboard short-circuit loop isolator550A quiescent current19.5mA alarm current 24V DC VAD lit voice sounder on maxGroup addressing facility allows multiple devices to be operated simultaneously7 selectable volume levels and up to 15 selectable tone pairsIP21C Type A rated GBP 95.84 1
C-Tec BF447ACXDR Addressable Wall Voice Sounder VAD with Deep Base C-Tec BF447ACXDR Addressable Wall Voice Sounder VAD with Deep BaseThe BF447ACXDR is a Hi-Output wall VAD with voice sounder designed with superb sound intelligibility for use with the C-Tec addressable range of control panels.Key FeaturesIncludes three selectable voice message pairsProvides W-2.4-8.2 light distribution when wallmounted min 0.4 lux over a 2.4m x 8.2mcuboidarea using the same lens and electronics as our EN54-23 3 17 certified wall sounder VADOnboard short-circuit loop isolator550A quiescent current19.5mA alarm current 24V DC VAD lit voice sounder on maxGroup addressing facility allows multiple devices to be operated simultaneously7 selectable volume levels and up to 15 selectable tone pairsIP33C Type B rated GBP 101.59 1
C-Tec CP411T CAST-PRO CO Fire Smoke Heat Multisensor cw Tone Sounder C-Tec CP411T CAST-PRO CO Fire Smoke Heat Multisensor cw Tone SounderA programmable CAST-PRO CO fire smoke heat multisensorfire detector which is certified to EN54-5 7 17 29 31. It is compatiblewith C-TECs ZFP touchscreen-controlled CAST protocol addressable fire panel.MASC Miniature Advanced Smoke Detection Chamber andAFFIRM algorithms provide incredible tolerance to false alarms whilstenhancing the detection of real fire conditions.Key FeaturesDrift compensation functionalityOnboard short circuit loop isolatorIncludes two 8mm x 2mm ultra-bright red LED indicatingstripsMultiple detection modes and different sensitivities fordifferent times of the day1mA alarm current max vol VAD on630uA typical quiescent current 40V DCCompatible with C-TECs CA408 CAST base cw integratedlocking mechanism ID tagComes with Tone Sounder GBP 99.79 1
C-Tec CA47067 CA Manual Call Point Surface IP67 Red C-Tec CA47067 CA Manual Call Point Surface IP67 RedA high-quality IP67 rated surface-mounting red manual callpoint for use with C-TECs XFP ZFP CAST protocol Addressable FirePanels.CAST is the worlds most-advanced distributedintelligence fire alarm system protocol. Conceived designed and realised byC-TEC as part of a five-year multi-million pound project it involved thecreation of a powerful proprietary communication protocol C-TEC AddressableSystem Technology CAST and multiple control panels field devices.Key FeaturesOnboard short-circuit loop isolatorSmooth-action resettable element mimics the feel of breakingglassSupplied with resetback box removal key and Not in UselabelRed LED alarm ring illuminates call point face uponactivationPhotoluminescent operating window remains visible for up to5 minutes5mA typical alarm current 370uA typical quiescent 22-40VDC GBP 93.76 1
C-Tec CA447ADR CA Wall Voice Sounder VAD - Deep - Red C-Tec CA447ADR CA Wall Voice Sounder VAD - Deep - RedThe CA447ADR is a red wall mounted high output addressablewall VAD and voice sounder with an IP33C deep base designed for use on C-TecCAST protocol analogue addressable fire alarm systems. CAST is the worlds most-advanced distributedintelligence fire alarm system protocol. Conceived designed and realised byC-TEC as part of a five-year multi-million-pound project it involved thecreation of a powerful proprietary communication protocol C-TEC AddressableSystem Technology CAST and multiple control panels field devices.Key FeaturesSuperb sound intelligibilityOnboard short-circuit loop isolatorFour selectable volume levelsSix selectable messages with tonesProvides W-2.75-9 or W-4-4 rated light distribution26.5mA typical alarm current 470A typical quiescentcurrent 27-40V DCGroup addressing facility allows multiple devices to beoperated simultaneouslyIP33C rated GBP 90.85 1
C-Tec ECU723 SigTEL InterfaceNetwork Communication Card C-Tec ECU723 SigTEL InterfaceNetwork Communication CardECU-224 interfacenetwork card. Allows an ECU-224 desk controller to be connected to an ECU-4 8 or 16. Can also act as a network card if networking is required. NOT compatible with ECU-8NT Controllers.The ECU723 transmits speech via a single wiring loop and digital data via two linear RS485 networks. The network should be connected using 4 x 2-core 1.5 mm2 enhanced fire-rated cable. Max. length of all networks is 1 km.An optional system expansion device.Allows anECU-224 desk controller to be connected to an ECU-4 8or16 SigTEL controller to simplify call handling on larger SigTEL applications.Mounts inside an ECU-4 8 or 16 can alsobe used tonetworkthe ECU-4 8 or 16 to another controller if required.Not compatible with ECU-8NT controllers.See schematicfull instructions for further details GBP 108.77 1
C-Tec CP414TVR CAST-PRO Smoke Heat Multisensor cw Tone Sounder amp O-C-1.9-4 Red VAD C-Tec CP414TVR CAST-PRO Smoke Heat Multisensor cw ToneSounder O-C-1.9-4 Red VADMultiple functionality in a single device smoke heatmultisensor fire detection plus a 92dbA tone Alarm sounder and an O-C-1.9-4red VAD detects real fires quickly reduces false alarms effectively andindicates true alarm conditions decisively.Key FeaturesCertified to EN54-3 5 7 17 23 29.Compatible with C-TECs ZFP touchscreen-controlled CASTprotocol addressable fire panel.MASC Miniature Advanced Smoke Detection Chamber andAFFIRM algorithms provide incredible tolerance to false alarms whilstenhancing the detection of real fire conditions.Drift compensation functionality.Onboard short circuit loop isolator.Includes two 8mm x 2mm ultra-bright red LED indicatingstrips.Multiple detection modes and different sensitivities fordifferent times of the day.13.2mA max. alarm current max vol VAD on.590uA typical quiescent current 40V DC.Compatible with C-TECs CA408 CAST base cwintegrated locking mechanism ID tag. GBP 133.36 1
C-Tec CP411TV CAST-PRO CO Fire Smoke Heat Multisensor cw Tone Sounder amp C-3-9.4 White VAD C-Tec CP411TV CAST-PRO CO Fire Smoke Heat Multisensorcw Tone Sounder C-3-9.4 White VADA multiple functionality in a single device CO fire heat smoke multisensor fire detection plus a 92dbA tone Alarm sounder and aC-3-9.4 VAD detects real fires quickly reduces false alarms effectively andindicates true alarm conditions decisively.Key FeaturesCertified to EN54-3 5 7 17 23 29 31Compatible with C-TECs ZFP touchscreen-controlled CASTprotocol addressable fire panelMASC Miniature Advanced Smoke Detection Chamber andAFFIRM algorithms provide incredible tolerance to false alarms whilstenhancing the detection of real fire conditionsDrift compensation functionalityOnboard short circuit loop isolatorIncludes two 8mm x 2mm ultra-bright red LED indicatingstripsMultiple detection modes and different sensitivities fordifferent times of the day13.2mA max. alarm current max vol VAD on630uA typical quiescent current 22-40V DCCompatible with C-TECs CA408 CAST base cw integratedlocking mechanism ID tag GBP 149.69 1
C-Tec CP414V CAST-PRO Smoke Heat Multisensor cw Voice Sounder C-Tec CP414V CAST-PRO Smoke Heat Multisensor cw VoiceSounderA multiple functionality in a single device smoke heat multisensor fire detection plus an 86dbA voice sounder detects realfires quickly reduces false alarms effectively and indicates true alarmconditions decisively.Key FeaturesCertified to EN54-3 5 7 17 29.Compatible with C-TECs ZFPtouchscreen-controlled CAST protocol addressable fire panel.MASC Miniature Advanced Smoke DetectionChamber and AFFIRM algorithms provide incredible tolerance to false alarmswhilst enhancing the detection of real fire conditions.Drift compensation functionality.Onboard short circuit loop isolator.Includes two 8mm x 2mm ultra-bright red LEDindicating strips.Multiple detection modes and differentsensitivities for different times of the day.Six selectable voice messages with tones 2evacuate 1 alert 1 all clear 2 system test messages.17.1mA max. alarm current max vol VAD on.590uA typical quiescent current 40V DC.Compatible with C-TECs CA408 CAST base cwintegrated locking mechanism ID tag. GBP 110.68 1
C-Tec CP414TV CAST-PRO Smoke Heat Multisensor cw Tone Sounder amp C-3-9.4 White VAD C-Tec CP414TV CAST-PRO Smoke Heat Multisensor cw ToneSounder C-3-9.4 White VADMultiple functionality in a single device smoke heatmultisensor fire detection plus a 92dbA tone Alarm sounder and a C-3-9.4 VAD detects real fires quickly reduces false alarms effectively and indicatestrue alarm conditions decisively.Key FeaturesCertified to EN54-3 5 7 17 23 29.Compatible with C-TECs ZFP touchscreen-controlled CASTprotocol addressable fire panel.MASC Miniature Advanced Smoke Detection Chamber andAFFIRM algorithms provide incredible tolerance to false alarms whilstenhancing the detection of real fire conditions.Drift compensation functionality.Onboard short circuit loop isolator.Includes two 8mm x 2mm ultra-bright red LED indicatingstrips.Multiple detection modes and different sensitivities fordifferent times of the day.13.2mA max. alarm current max vol VAD on.590uA typical quiescent current 40V DC.Compatible with C-TECs CA408 CAST base cwintegrated locking mechanism ID tag. GBP 112.94 1
C-Tec CP411V CAST-PRO CO Fire Smoke Heat Multisensor cw Voice Sounder C-Tec CP411V CAST-PRO CO Fire Smoke Heat Multisensor cwVoice SounderMultiple functionality in a single device CO fire smoke heat multisensor fire detection plus an 86dbA voice sounder detectsreal fires quickly reduces false alarms effectively and indicates true alarmconditions decisively. It is certified to EN54-3 5 7 17 29 31.Compatible with C-TECs ZFP touchscreen-controlled CASTprotocol addressable fire panel.Key FeaturesMASC Miniature Advanced Smoke Detection Chamber andAFFIRM algorithms provide incredible tolerance to false alarms whilstenhancing the detection of real fire conditionsDrift compensation functionalityOnboard short circuit loop isolatorIncludes two 8mm x 2mm ultra-bright red LED indicatingstripsMultiple detection modes and different sensitivities fordifferent times of the daySix selectable voice messages with tones 2 evacuate 1alert 1 all clear 2 system test messages17.1mA max. alarm current max vol VAD on630uA typical quiescent current 40V DCCompatible with C-TECs CA408 CAST base cw integratedlocking mechanism ID tag GBP 136.08 1
C-Tec CP411TVR CAST-PRO CO Fire Smoke Heat Multisensor cw Tone Sounder amp O-C-1.9-4 Red VAD C-Tec CP411TVR CAST-PRO CO Fire Smoke Heat Multisensor cw Tone Sounder O-C-1.9-4 Red VADA multiple functionality in a single device CO fire heat smoke multisensor fire detection plus a 92dbA tone Alarm sounder and aO-C-1.9-4 red VAD detects real fires quickly reduces false alarms effectively andindicates true alarm conditions decisively.Key FeaturesCertified to EN54-3 5 7 17 23 29 31Compatible with C-TECs ZFP touchscreen-controlled CASTprotocol addressable fire panelMASC Miniature Advanced Smoke Detection Chamber andAFFIRM algorithms provide incredible tolerance to false alarms whilstenhancing the detection of real fire conditionsDrift compensation functionalityOnboard short circuit loop isolatorIncludes two 8mm x 2mm ultra-bright red LED indicatingstripsMultiple detection modes and different sensitivities fordifferent times of the day13.2mA max. alarm current max vol VAD on630uA typical quiescent current 22-40V DCCompatible with C-TECs CA408 CAST base cw integratedlocking mechanism ID tag GBP 158.76 1
C-Tec CP414VV CAST-PRO Smoke Heat Multisensor cw Voice Sounder amp C-3-9.4 White VAD C-Tec CP414VV CAST-PRO Smoke Heat Multisensor cw VoiceSounder C-3-9.4 White VADA multiple functionality in a single device smoke heat multisensor fire detection plus an 86dbA voice sounder and a C-3-9.4 VAD detects real fires quickly reduces false alarms effectively and indicatestrue alarm conditions decisively.Key FeaturesCertified to EN54-3 5 7 17 23 29.Compatible with C-TECs ZFP touchscreen-controlled CASTprotocol addressable fire panel.MASC Miniature Advanced Smoke Detection Chamber andAFFIRM algorithms provide incredible tolerance to false alarms whilstenhancing the detection of real fire conditions.Drift compensation functionality.Onboard short circuit loop isolator.Includes two 8mm x 2mm ultra-bright red LED indicatingstrips.Multiple detection modes and different sensitivities fordifferent times of the day.Six selectable voice messages with tones 2 evacuate 1alert 1 all clear 2 system test messages.24.9mA max. alarm current max vol VAD on.590uA typical quiescent current 40V DC.Compatible with C-TECs CA408 CAST base cwintegrated locking mechanism ID tag. GBP 160.57 1
C-Tec CP414VVR CAST-PRO Smoke Heat Multisensor cw Voice Sounder amp O-C-1.9-4 Red VAD C-Tec CP414VVR CAST-PRO Smoke Heat Multisensor cw VoiceSounder O-C-1.9-4 Red VADA multiple functionality in a single device smoke heat multisensor fire detection plus an 86dbA voice sounder and an O-C-1.9-4red VAD detects real fires quickly reduces false alarms effectively andindicates true alarm conditions decisively.Key FeaturesCertified to EN54-3 5 7 17 23 29.Compatible with C-TECs ZFP touchscreen-controlled CASTprotocol addressable fire panel.MASC Miniature Advanced Smoke Detection Chamber andAFFIRM algorithms provide incredible tolerance to false alarms whilstenhancing the detection of real fire conditions.Drift compensation functionality.Onboard short circuit loop isolator.Includes two 8mm x 2mm ultra-bright red LED indicatingstrips.Multiple detection modes and different sensitivities fordifferent times of the day.Six selectable voice messages with tones 2 evacuate 1alert 1 all clear 2 system test messages.24.9mA max. alarm current max vol VAD on.590uA typical quiescent current 40V DC.Compatible with C-TECs CA408 CAST base cw integratedlocking mechanism ID tag. GBP 169.64 1