648 results (0,14594 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

C-TEC Glazed Stainless Steel Frame for ZFP Standard Cabinet

C-Tec AMP Professional Handheld Microphone

C-Tec AMD Desktop Microphone

C-Tec AML Lectern Microphone

C-Tec PRO45 Hanging Ambient Microphone

C-Tec AMDS Desktop Short Stemmed Microphone

C-Tec AMDP Desktop Microphone with Push to Talk

C-Tec AMLS Lectern Short Stemmed Microphone

C-Tec AMC Cardiod Ambient Ceiling Microphone

C-Tec AMRLA Lavalier Radio Microphone Kit

C-Tec AMRHA Handheld Radio Microphone Kit

C-Tec Z928 Zener Barrier - 1 Channel

C-Tec FF396-2 FP10 10Z Fire Repeater Panel

C-Tec QT951 Quantec Addressable Accessible Toilet Alarm Kit

C-Tec QT951 Quantec Addressable Accessible Toilet Alarm Kit

C-Tec QT951 Quantec Addressable Accessible Toilet Alarm KitA cost-effective expansion kit that adds true BS8300 compliant accessible toilet alarm functionality to a Quantec Addressable Call System. Includes a QT607 ceiling pull unit a QT605S reset point cw confidence sounder a Quantec slave overdoor light cw sounder and an NC949 Accessible Toilet Sticker.Key FeaturesAllows people in distress to call for help quickly and easily.Call acknowledgement function provides audible visual feedback inside the WC that help is on the way see Operation section below.Staff can Accept alarm calls at a Quantec display.Multiple kits can be used on one Quantec system.Includes a free MRSA resistant anti-bacterial pull cord pack for a limited period only.Backwards compatible.Must be used in conjunction with at least one Quantec Controller.Operating1. The distressed person raises an alarm by pulling the cord on the QT607 Ceiling Pull Unit.Inside the WC The red reassurance LED on the QT607 Ceiling Pull Unit and the reassurance LED and sounder on the QT605S Reset Point cw Sounder pulse Quantecs standard call sequence 0.5 seconds on and 0.5 seconds off to reassure the user the call has been registered.Outside the WC The Alarm LEDs and sounder on the QT606S Overdoor Light cw Sounder pulse Quantecs standard call sequence 0.5 seconds on 0.5 seconds off and a message appears on all relevant Quantec displays as programmed to let staff know someone is in need of assistance.2. The member of staff responding to the Alarm call presses the Call Accept button on a Quantec DisplayInside the WC The reassurance LED and sounder on the QT605S Reset Point cw Sounder pulse Quantecs Call Acknowledged sequence 0.5 seconds on 3 seconds off redgreen to let the user know help is on the way.3. Once assistance has been provided the Alarm call is cancelled from inside the WC by pressing the RESET button on the QT605S Reset Point cw SounderInside and outside the WC All relevant indicators display messages and sounders are extinguished and the calling device returns to its normal state.If the RESET button on the QT605S is NOT pressed when in the call acknowledged state after a period of 1 to 8 minutes as programmed it generates another AlarmStandard call on the system.

GBP 110.95
1

C-Tec QT609SSS Quantec Stainless Steel Call Point - Button Reset with Sounder Single Gang

C-Tec BF365SC Sounder Isolator Controller

C-Tec BF365SC Sounder Isolator Controller

BF365SC Sounder Isolator ControllerBF365SC Conventional Sounder Controller and its associated BF365IM Isolator Modules are designed to interface to a fire alarm panels conventional sounder circuit. The Modules each of which would typically have a conventional sounder connected to it are wired in a loop arrangement beginning and ending at the controller. The Controller transforms the conventional sounder circuits monitoring and triggering voltages into its own unique control voltages which it uses to trigger the Isolator Modules and monitor the sounder loop wiring.Each Module has smart sensing which means if a wiring fault should occur the Modules nearest to the faulty section of cabling will if needed isolate this section. As the Modules are driven from each direction any loss of cable integrity will have no effect on the functionality of the actual sounders. Having a fault tolerant arrangement such as this means that low cost cabling can be used for the sounder circuit subject to the fire officers approval leading to significant savings in installation.Key FeaturesDesigned to meet requirement 17.9.2c of Dutch standard NEN2575BSI certified to EN54 parts 17 18Easily interfaced to a conventional fire alarm sounder circuitAllows low-cost non-fire resistant sounder circuit cabling to be used when used in conjunction with our BF365IM Isolator Modules subject to fire officer approval.Wiring must be made in a loop arrangement beginning and ending at the controllerIf a wiring fault should occur the Modules nearest to the faulty section of cabling will if needed isolate this section. As the Modules are driven from each direction any loss of cable integrity will have no effect on the functionality of the actual soundersFits on standard UK 25mm flush or surface mount back boxesNot suitable for use in the UK

GBP 77.21
1

C-Tec STI-6931G STI Call Point Stopper - Green - Surface