C-Tec PL1SHELF Wall Mounting Storage Shelf for PL1 Amplifier C-Tec PL1SHELF Wall Mounting Storage Shelf for PL1 AmplifierAttractive easy-to-fit mounting accessory that safely and securely holds a PL1 portable loop amplifier when it is not in use. Includes a pre-cut hole for feeding through the plug-top power supplyslead to the PL1s charger socket so theamplifier can becharged whilst stored on the shelf.Key FeaturesBuilt-in pocket for instruction storage.Finished in black high-impact plastic.Technical SpecificationsApplication operation allows the PL1 portable hearing loop amplifier to be safely stored on a wallProduct dimensions W260 x H263 x D14 mmConstructions Black high impact plastic shelfWeight 360g GBP 43.88 1
C-Tec PL1K1 Portable Hearing Loop Kit with Storage Shelf 1.2m2 C-Tec PL1K1 Portable Hearing Loop Kit with Storage Shelf 1.2m2Hearing loop systems allow hearing impaired people to hear more clearly. Most hearing aids have a T or MT switch which allows them to pick up the electromagnetic field generated by a hearing loop system. The hearing aid converts this signal into a sound suited to its users specific hearing requirements.Any person with a hearing aid positioned within or near the loop can hear the loop signal by switching their hearing aid to the correct position allowing them to participate more effectively in general conversation ordering goods or services listening to public performances etc.The PL1K1 is ideal for restricted person to person contact in areas such as banks post offices small meeting rooms reception desks open plan offices and ticket booths. The units portable lightweight design means the system can be moved easily from location to location.Key FeaturesSimple one button operation.Integral high-performance microphone.Excellent sound quality.Five years expected battery life under normal operatingcharging conditions.Auto shut-off facility user selectable for 10 30 or 60 minutes helps preserve battery life.Connection of the plug-top charger overrides the timer function to ensure the unit remains operational at all times.Unit can be used as normal whilst charging.Technical SpecificationType - PortableCoverage - 1.2m2 approx.Dimensions - W 271 x H 200 x D 77mm amplifier only 2.82kgInputs 2 x Mic one built-in mic. and one 3.5mm remote mic. socket for AMT or AMD micsIndicators - Power on input level charging required charging in progress audio warning of imminent shutdownControls - Onoff button adjust auto-shut off timer GBP 202.64 1
C-Tec ZFP1CA ZFP 1 Loop Panel 5A CAST C-Tec ZFP1CA ZFP 1 Loop Panel 5A CASTA feature-rich touchscreen-controlled addressable fire panelwith C-Tec CAST compatible loop drivers.Key FeaturesThird-party certified to EN54 parts 2 4 and 13Multiple off-the-shelf variants or build your own panelusing our ZFP selection chartsRapid loop learn flexible cause effects and powerfulsystem diagnosticsHi-integrity fault-tolerant RS485 networking option allowsup to 128 network nodes 64 main panels and 64 Compact ControllersOptional A-Bus expansion PCBs paging and graphicinterface facilitiesENVISION Enabled fullly compatible with C-TECs new Cloudbased data managementremote access softwareIntuitive PC programming tools GBP 968.87 1
C-Tec ZFP220CA ZFP 2 Loop 5A 20LED CAST C-Tec ZFP220CA ZFP 2 Loop 5A 20LED CASTA feature-rich touchscreen-controlled addressable fire panelwith C-Tec CAST compatible loop drivers.Key FeaturesThird-party certified to EN54 parts 2 4 and 13Multiple off-the-shelf variants or build your own panelusing our ZFP selection chartsRapid loop learn flexible cause effects and powerfulsystem diagnosticsHi-integrity fault-tolerant RS485 networking option allowsup to 128 network nodes 64 main panels and 64 Compact ControllersOptional A-Bus expansion PCBs paging and graphicinterface facilitiesENVISION Enabled fullly compatible with C-TECs new Cloudbased data managementremote access softwareIntuitive PC programming tools GBP 1463.90 1
C-Tec ZFP2CA ZFP 2 Loop Panel 5A Cast C-Tec ZFP2CA ZFP 2 Loop Panel 5A CastA feature-rich touchscreen-controlled addressable fire panelwith C-Tec CAST compatible loop drivers.Key FeaturesThird-party certified to EN54 parts 2 4 and 13Multiple off-the-shelf variants or build your own panelusing our ZFP selection chartsRapid loop learn flexible cause effects and powerfulsystem diagnosticsHi-integrity fault-tolerant RS485 networking option allowsup to 128 network nodes 64 main panels and 64 Compact ControllersOptional A-Bus expansion PCBs paging and graphicinterface facilitiesENVISION Enabled fullly compatible with C-TECs new Cloudbased data managementremote access softwareIntuitive PC programming tools GBP 1346.05 1
C-Tec ZFP120CA ZFP 1 Loop Panel 5A 20LED CAST C-Tec ZFP120CA ZFP 1 Loop Panel 5A 20LED CASTA feature-rich touchscreen-controlled addressable fire panelwith C-Tec CAST compatible loop drivers.Key FeaturesThird-party certified to EN54 parts 2 4 and 13Multiple off-the-shelf variants or build your own panelusing our ZFP selection chartsRapid loop learn flexible cause effects and powerfulsystem diagnosticsHi-integrity fault-tolerant RS485 networking option allowsup to 128 network nodes 64 main panels and 64 Compact ControllersOptional A-Bus expansion PCBs paging and graphicinterface facilitiesENVISION Enabled fullly compatible with C-TECs new Cloudbased data managementremote access softwareIntuitive PC programming tools GBP 1084.37 1
C-Tec ZFP140CA ZFP 1 Loop Panel 5A 40LED CAST C-Tec ZFP140CA ZFP 1 Loop Panel 5A 40LED CASTA feature-rich touchscreen-controlled addressable fire panelwith C-Tec CAST compatible loop drivers.Key FeaturesThird-party certified to EN54 parts 2 4 and 13Multiple off-the-shelf variants or build your own panelusing our ZFP selection chartsRapid loop learn flexible cause effects and powerfulsystem diagnosticsHi-integrity fault-tolerant RS485 networking option allowsup to 128 network nodes 64 main panels and 64 Compact ControllersOptional A-Bus expansion PCBs paging and graphicinterface facilitiesENVISION Enabled fullly compatible with C-TECs new Cloudbased data managementremote access softwareIntuitive PC programming tools GBP 1123.87 1
C-Tec ZFP240CA ZFP 2 Loop Panel 5A 40LED CAST C-Tec ZFP240CA ZFP 2 Loop Panel 5A 40LED CASTA feature-rich touchscreen-controlled addressable fire panelwith C-Tec CAST compatible loop drivers.Key FeaturesThird-party certified to EN54 parts 2 4 and 13Multiple off-the-shelf variants or build your own panelusing our ZFP selection chartsRapid loop learn flexible cause effects and powerfulsystem diagnosticsHi-integrity fault-tolerant RS485 networking option allowsup to 128 network nodes 64 main panels and 64 Compact ControllersOptional A-Bus expansion PCBs paging and graphicinterface facilitiesENVISION Enabled fullly compatible with C-TECs new Cloudbased data managementremote access softwareIntuitive PC programming tools GBP 1501.15 1
C-Tec ZFP240PCA ZFP 2 Loop Panel 5A 40LED CAST cw Printer C-Tec ZFP240PCA ZFP 2 Loop Panel 5A 40LED CAST cw PrinterA feature-rich touchscreen-controlled addressable fire panelwith C-Tec CAST compatible loop drivers.Key FeaturesThird-party certified to EN54 parts 2 4 and 13Multiple off-the-shelf variants or build your own panelusing our ZFP selection chartsRapid loop learn flexible cause effects and powerfulsystem diagnosticsHi-integrity fault-tolerant RS485 networking option allowsup to 128 network nodes 64 main panels and 64 Compact ControllersOptional A-Bus expansion PCBs paging and graphicinterface facilitiesENVISION Enabled fullly compatible with C-TECs new Cloudbased data managementremote access softwareIntuitive PC programming tools GBP 1873.62 1
C-Tec ZFP120PCA ZFP 1 Loop Panel 5A 20LED CAST cw Printer C-Tec ZFP120PCA ZFP 1 Loop Panel 5A 20LED CAST cw PrinterA feature-rich touchscreen-controlled addressable fire panelwith C-Tec CAST compatible loop drivers.Key FeaturesThird-party certified to EN54 parts 2 4 and 13Multiple off-the-shelf variants or build your own panelusing our ZFP selection chartsRapid loop learn flexible cause effects and powerfulsystem diagnosticsHi-integrity fault-tolerant RS485 networking option allowsup to 128 network nodes 64 main panels and 64 Compact ControllersOptional A-Bus expansion PCBs paging and graphicinterface facilitiesENVISION Enabled fullly compatible with C-TECs new Cloudbased data managementremote access softwareIntuitive PC programming tools GBP 1456.82 1
C-Tec ZFP220PCA ZFP 2 Loop Panel 5A 20LED CAST cw Printer C-Tec ZFP220PCA ZFP 2 Loop Panel 5A 20LED CAST cw PrinterA feature-rich touchscreen-controlled addressable fire panelwith C-Tec CAST compatible loop drivers.Key FeaturesThird-party certified to EN54 parts 2 4 and 13Multiple off-the-shelf variants or build your own panelusing our ZFP selection chartsRapid loop learn flexible cause effects and powerfulsystem diagnosticsHi-integrity fault-tolerant RS485 networking option allowsup to 128 network nodes 64 main panels and 64 Compact ControllersOptional A-Bus expansion PCBs paging and graphicinterface facilitiesENVISION Enabled fullly compatible with C-TECs new Cloudbased data managementremote access softwareIntuitive PC programming tools GBP 1834.01 1
C-Tec ZFP140PCA ZFP 1 Loop Panel 5A 40LED CAST cw Printer C-Tec ZFP140PCA ZFP 1 Loop Panel 5A 40LED CAST cw PrinterA feature-rich touchscreen-controlled addressable fire panelwith C-Tec CAST compatible loop drivers.Key FeaturesThird-party certified to EN54 parts 2 4 and 13Multiple off-the-shelf variants or build your own panelusing our ZFP selection chartsRapid loop learn flexible cause effects and powerfulsystem diagnosticsHi-integrity fault-tolerant RS485 networking option allowsup to 128 network nodes 64 main panels and 64 Compact ControllersOptional A-Bus expansion PCBs paging and graphicinterface facilitiesENVISION Enabled fullly compatible with C-TECs new Cloudbased data managementremote access softwareIntuitive PC programming tools GBP 1496.45 1
C-Tec ECU-224 SigTEL 224 Line Desk Controller C-Tec ECU-224 SigTEL 224 Line Desk ControllerOptional 1-224 line SigTEL Desk Controller with handset display. Requires an ECU723 fitted at an ECU-4 8 or 16 Controller. ECU-224s are NOT compatible with ECU-8NT Controllers.A new 224line Desk Controllerfor use with our SigTEL disabled refuge fire telephone and stadium marshallingsystem.Allows operators to communicate with up to 224disabled refuge or fire telephone outstations.Designed to simplify call-handling on larger EVC installations.Must be connected to an ECU-4 8 or 16 master controller viaan ECU-723 interfacenetwork card.Although designed to be free-standing an optional sloping wall mounting shelf is available order code ECUWMB.See schematicfull instructions for further details. GBP 968.15 1
C-Tec BF560-12E Switch Mode 12v 2A Caged PSU PCB C-Tec BF560-12E Switch Mode 12v 2A Caged PSU PCBTheBF560-12E is apowerful switch modedigital hybrid PSU that can be customised to suit your exact requirements. The plasticcoveron PSU PCB guards against touching live parts to VDE 0100-410. Includes the same electronics as the BF560-12 LPCBcertified EN54-4A2 boxed 12V 2A PSU.Key FeaturesMetal base platefacilitatesstraightforwardmountinginside third-party OEMenclosures.Includes a single-pole voltfree changeover relay that switches for any fault condition.Includes afault type hazardous voltages present LED.Two selectable battery charge currents.Battery fault impedance limits can be optimised to suit load current helps extend battery life.Mains fail simulation mode.Improved on-board temperature sensor with optional remote sensor.Electronic functions comply with EN50131-6 grades 1-4 for security applications.Additional InformationEN50131-6 POWER SUPPLIES FOR INTRUSION HOLD UP ALARMS CAPABILITYThe BF560-12E has all the electrical functions required to comply with EN50131-6 Grade 4which includes Grades 3 2 and 1. OEM security companies interested in utilising the BF560-12E inside their own EN50131-6 compliant tamper-resistant enclosures should contact our marketing departmentfor further detailson costs and approvals.PSU CUSTOMISATIONThe BF560-12Ecan be customised to suit your exact requirements using a BF423 configurator PC. Configurable parameters include float voltage temperature compensation battery charge rate mA battery impedance and configurableInputOutput settingsPSU STATUS LEDlocated on the PSU PCB1 flash Mains Failure.2 flashes Battery Voltage Low.3 flashes Battery Voltage Critical.4 flashes Charger Failure.5 flashes Charger OK Battery is either actively charging or in float charge.6 flashes No Batteries Fitted indicating DIP Switch 4 position.7 flashes Battery Resistance Fault Level set by DIP Switch 2 position.8flashes Output Over Voltage.BATTERY FAULT MONITORINGThe BF560-12E monitors battery resistance to the requirements of EN54-4A2. The fault threshold is directly related to the ability of the battery to deliver the rated current to the load. For example batteries stored uncharged for long periods during shipment andor distribution degrade leading to increased internal resistance. If a degraded battery is fitted a fault will be shown by the PSU as mandated by EN54-4A2.DATA PORTData on the BF560-12Es status can be extracted from the PSUsbi-directional data port. The data availableincludes thermistor measurements battery terminal voltage system voltage at load terminals battery charge current load current battery impedanceandASCII text string status messages. Extracting this data requires additional equipment and permissions - contact C-TEC for details. GBP 70.52 1
C-Tec BF562-1 Switch Mode 24v 1.5A EN54-4 Boxed Metal PSU C-Tec BF562-1 Switch Mode 24v 1.5A EN54-4 Boxed Metal PSUThe BF562-1 is certified to EN54-4A2 by the LPCB and VdS AFNOR pending. It comes with a plastic cover on PSU PCB which guards against touching live parts. Includes a single-pole voltfree changeover relay that switches for any fault condition.Key FeaturesMultiple indicators - supply present general fault fault type aux. equipment faultTwo selectable battery charge currentsBattery fault impedance limits can be optimised to suit load current helps extend battery lifeMains fail simulation modeImproved on-board temperature sensor with optional remote sensorElectronic functions comply with EN50131-6 grades 1-4 for security applicationsBF562-1E caged BF562-1C PCB-only versions availableTYPICAL USESIdeal for poweringbeam detectors auto-dial communicators aspirating smoke detectors auto-open vent systems auxiliary sounder systems or any other device performing a mandatory function of a fire alarm system.PSU CUSTOMISATIONThe BF562-1can be customised to suit your exact requirements using a BF423 configurator PC. Configurable parameters include float voltage temperature compensation battery charge rate mA battery impedance and configurableInputOutput settings. It is important to note changing the PSUs parameters in this way isoutside the scope of EN54-4 and any changes mustbe tested by the responsible person for correctoperation.PSU STATUS LEDlocated on the PSU PCB1 flash Mains Failure.2 flashes Battery Voltage Low.3 flashes Battery Voltage Critical.4 flashes Charger Failure.5 flashes Charger OK Battery is either actively charging or in float charge.6 flashes No Batteries Fitted indicating DIP Switch 4 position.7 flashes Battery Resistance Fault Level set by DIP Switch 2 position.8flashes Output Over Voltage.BATTERY FAULT MONITORINGThe BF562-1 complies with EN54-4A2 and therefore must monitor battery resistance. The fault threshold is directly related to the ability of the battery to deliver the rated current to the load. For example batteries stored uncharged for long periods during shipment andor distribution degrade leading to increased internal resistance. If a degraded battery is fitted a fault will be shown by the PSU as mandated by EN54-4A2.DATA PORTData on the BF562-1s status can be extracted from the PSUsbi-directional data port. The data availableincludes thermistor measurements battery terminal voltage system voltage at load terminals battery charge current load current battery impedanceandASCII text string status messages. Extracting this data requires additional equipment and permissions - contact C-TEC for details. GBP 155.72 1
C-Tec ZFP2MCA ZFP 2 Loop Panel 5A Cast - Medium Cabinet C-Tec ZFP2MCA ZFP 2 Loop Panel 5A Cast - Medium CabinetA feature-rich touchscreen-controlled addressable fire panelwith C-Tec CAST compatible loop drivers.Created with the input of some of the worlds leading fire alarm and life safety experts the ZFP is the powerful touchscreen controlled fire alarm panel that everyones been waiting for.Designed and built in the UK the panel can be configured to suit any application. From small one out all out systems to large multi-loop networked systems with sophisticated cause and effects the ZFP can handle them all with ease.Simply tap the option you require and away you go. Whether youre the responsible person on site the installer the commissioning engineer or the emergency services you can access the information you require quickly and easily - all at the touch of a virtual button.Creating a sophisticated fire alarm system for an airport hospital university tower block hotel football stadium or other large building is just a few steps up from establishing a simple one out all out system for a small factory unit.All this and full compliance with EN54 parts 2 and 4 means that the ZFP is rapidly becoming the fire panel of choice for the fire industry worldwide.Key FeaturesThird-party certified to EN54 parts 2 4 and 13Multiple off-the-shelf variants or build your own panelusing our ZFP selection chartsRapid loop learn flexible cause effects and powerfulsystem diagnosticsHi-integrity fault-tolerant RS485 networking option allowsup to 128 network nodes 64 main panels and 64 Compact ControllersOptional A-Bus expansion PCBs paging and graphicinterface facilitiesENVISION Enabled fullly compatible with C-TECs new Cloudbased data managementremote access softwareIntuitive PC programming toolsMedium cabinet GBP 1640.72 1
C-Tec ZFP2LCA ZFP 2 Loop Panel 5A Cast - Large Cabinet C-Tec ZFP2LCA ZFP 2 Loop Panel 5A Cast - Large CabinetA feature-rich touchscreen-controlled addressable fire panelwith C-Tec CAST compatible loop drivers.Created with the input of some of the worlds leading fire alarm and life safety experts the ZFP is the powerful touchscreen controlled fire alarm panel that everyones been waiting for.Designed and built in the UK the panel can be configured to suit any application. From small one out all out systems to large multi-loop networked systems with sophisticated cause and effects the ZFP can handle them all with ease.Simply tap the option you require and away you go. Whether youre the responsible person on site the installer the commissioning engineer or the emergency services you can access the information you require quickly and easily - all at the touch of a virtual button.Creating a sophisticated fire alarm system for an airport hospital university tower block hotel football stadium or other large building is just a few steps up from establishing a simple one out all out system for a small factory unit.All this and full compliance with EN54 parts 2 and 4 means that the ZFP is rapidly becoming the fire panel of choice for the fire industry worldwide.Key FeaturesThird-party certified to EN54 parts 2 4 and 13Multiple off-the-shelf variants or build your own panelusing our ZFP selection chartsRapid loop learn flexible cause effects and powerfulsystem diagnosticsHi-integrity fault-tolerant RS485 networking option allowsup to 128 network nodes 64 main panels and 64 Compact ControllersOptional A-Bus expansion PCBs paging and graphicinterface facilitiesENVISION Enabled fullly compatible with C-TECs new Cloudbased data managementremote access softwareIntuitive PC programming toolsLarge cabinetPlease note The image is for illustrative purposes only. GBP 1758.59 1
C-Tec BF560-12 Switch Mode 12v 2A EN54-4 Boxed PSU C-Tec BF560-12 Switch Mode 12v 2A EN54-4 Boxed PSUThe C-Tec BF560-12 12V 2A EN54-4 Switch Mode PSU is ideal for connecting to 12V security STUs to provide BS5839-1 compliant remote monitoring facilities. It is certified to EN54-4A2 by the LPCB VdS AFNOR pending.Key FeaturesMultiple indicators - supply present general fault fault type aux. equipment fault.Two selectable battery charge currents.Battery fault impedance limits can be optimised to suit load current helps extend battery life.Mains fail simulation mode.Improved on-board temperature sensor with optional remote sensor.Ideal for connecting to 12V security STUs to provide BS5839-1 compliant remote monitoring facilities.Electronic functions comply with EN50131-6 grades 1-4 for security applications.BF560-12E Caged BF560-12C PCB-only versions available.Plastic cover on PSU PCB guards against touching live parts.Includes a single-pole voltfree changeover relay that switches for any fault condition.Additional InformationPSU CUSTOMISATIONThe BF560-12can be customised to suit your exact requirements using a BF423 configurator PC. Configurable parameters include float voltage temperature compensation battery charge rate mA battery impedance and configurableInputOutput settings. It is important to note changing the PSUs parameters in this way isoutside the scope of EN54-4 and any changes mustbe tested by the responsible person for correctoperation.12V SECURITY STUUSED PURELY FOR FIRE ALARM SIGNALLINGThe BF560-12 can help combat an area of fire alarm system non-compliance that is often overlooked - their connection to remote monitoring centres via 12V security STUs or autodiallers. Firesystems that require such monitoring are typically connected to 12V security STUs. Unfortunately PSUs used to power these STUs normally only offer 12 hours standby are notconnected to a dedicated mains supply and do not include the features demanded by EN54-4 such as battery impedance monitoring temperature compensated charging CPR compliance etc. TheBF560-12 solves these problems by allowing the use of 12V STUs with a cost-effective EN54-4 compliant PSU thereby facilitating compliance with BS5839-1 or European equivalents. Tofurther assist this application an optional STU mounting plate is available for inside the BF560-12 order code BF360SP.PSU STATUS LEDlocated on the PSU PCB1 flash Mains Failure.2 flashes Battery Voltage Low.3 flashes Battery Voltage Critical.4 flashes Charger Failure.5 flashes Charger OK Battery is either actively charging or in float charge.6 flashes No Batteries Fitted indicating DIP Switch 4 position.7 flashes Battery Resistance Fault Level set by DIP Switch 2 position.8flashes Output Over Voltage.BATTERY FAULT MONITORINGThe BF560-12 complies with EN54-4A2 and therefore must monitor battery resistance. The fault threshold is directly related to the ability of the battery to deliver the rated current to the load. For example batteries stored uncharged for long periods during shipment andor distribution degrade leading to increased internal resistance. If a degraded battery is fitted a fault will be shown by the PSU as mandated by EN54-4A2.EN50131-6 POWER SUPPLIES FOR INTRUSION HOLD UP ALARMS CAPABILITYThe power supply inside the BF560-12 has all the electrical functions required to comply with EN50131-6 Grade 4which includes Grades 3 2 and 1. However the BF560-12s enclosure isnot designed to comply with the standardsrequirements totriggeranalarm if someone tries to force the box open. OEM security companies interested in utilising the BF560-12s PSUPCB inside their own EN50131-6 compliant tamper-resistant enclosures should contact our marketing departmentfor further detailson costs and approvals.DATA PORTData on the BF560-12s status can be extracted from the PSUsbi-directional data port. The data availableincludes thermistor measurements battery terminal voltage system voltage at load terminals battery charge current load current battery impedanceandASCII text string status messages. Extracting this data requires additional equipment and permissions -call C-TEC for details. GBP 113.64 1