C-Tec NC885 Standard 51 Input Expander C-Tec NC885 Standard 51 Input Expander -used to provide areazonal indicationInput expanders are used to give area indication and have five inputs and one output which can operate overdoor lights interface modules or zone indicators on a panel in another part of the building. The outputs of several input expanders can be connected together. Fix by self-adhesive pad.Key FeaturesSize53mm x 25mm x 20mm GBP 27.98 1
C-Tec BF431CF19 FUL Squashni G3 24V Ceiling Base Sounder White C-Tec BF431CF19 FUL Squashni G3 24V Ceiling Base Sounder WhiteThe third generation Squashni G3 amalgamates the best features from the previous Squashni and Squashni Micro versions. The large flat surface allows the mounting of a large range of European detectors while the high efficiency and low operating current permit compatibility with many systems.Key FeaturesFixing platform for most popular detectorsLow current consumptionTamper proof cover for standalone useFirst fix base for easier installationCombined sounder beacon version availableLED triggered version availableMED certification GBP 50.16 1
C-Tec CFP708-2 CFP Two Wire 8 Zone AlarmSense Control Panel C-Tec CFP Two Wire 8 Zone AlarmSense Control Panel - CFP708-2C-TECs LPCB certified two-wire CFP AlarmSense fire panel is designed to work with Apollos AlarmSense range of detectors call points sounders and beacons. Most conventional fire systems are designed to work with two pairs of wires per zone one pair for detection devices such as smoke detectors heat detectors and manual call points the other for alarm devices such as bells sounders or strobes. By using different voltage bands for quiescent and alarm states AlarmSense components can be connected to the same pair of supply wires.When powered and controlled by the CFP two-wire fire panel this reliable technology takes all the complexity out of fire alarm system design leading to quicker less expensive and more flexible installation. Indeed research shows an AlarmSense two-wire system can achieve a 20-25 reduction of labour over a standard four wire conventional system. AlarmSense devices are acceptable for BS 5839-1 and BS 5839-6 systems making them particularly useful for fire protection in Houses of Multiple Occupation HMOs.Key FeaturesLPCB certified to EN54 parts 2 and 4Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry to access level 22 4 or 8 AlarmSense zone circuits dependent on model purchasedFour conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSUWide range of engineering functions including zone test coincidence zone delay and non- latching zonesTwo on-board relays Fire and FaultTwo open-collector outputs Remote and ResetClass change and alert inputsInstaller-friendly design accommodates easy first fix and straightforward maintenanceAttractive flush or surface mountable plastic lid and enclosure - no bezel requiredLow quiescent currentMultiple indicatorsEnd of line units included one per zoneAncillary system expansion connections provided for up to eight two-wire repeaters one CFP761 network driver card required per system and optional CFP relay boardsSpace for two x 12V 3.3Ah VRLA batteries GBP 272.59 1
C-Tec CFP704-2 CFP Two Wire 4 Zone AlarmSense Control Panel C-Tec CFP Two Wire 4 Zone AlarmSense Control Panel - CFP704-2C-TECs LPCB certified two-wire CFP AlarmSense fire panel is designed to work with Apollos AlarmSense range of detectors call points sounders and beacons. Most conventional fire systems are designed to work with two pairs of wires per zone one pair for detection devices such as smoke detectors heat detectors and manual call points the other for alarm devices such as bells sounders or strobes. By using different voltage bands for quiescent and alarm states AlarmSense components can be connected to the same pair of supply wires.When powered and controlled by the CFP two-wire fire panel this reliable technology takes all the complexity out of fire alarm system design leading to quicker less expensive and more flexible installation. Indeed research shows an AlarmSense two-wire system can achieve a 20-25 reduction of labour over a standard four wire conventional system. AlarmSense devices are acceptable for BS 5839-1 and BS 5839-6 systems making them particularly useful for fire protection in Houses of Multiple Occupation HMOs.Key FeaturesLPCB certified to EN54 parts 2 and 4Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry to access level 22 4 or 8 AlarmSense zone circuits dependent on model purchasedFour conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSUWide range of engineering functions including zone test coincidence zone delay and non- latching zonesTwo on-board relays Fire and FaultTwo open-collector outputs Remote and ResetClass change and alert inputsInstaller-friendly design accommodates easy first fix and straightforward maintenanceAttractive flush or surface mountable plastic lid and enclosure - no bezel requiredLow quiescent currentMultiple indicatorsEnd of line units included one per zoneAncillary system expansion connections provided for up to eight two-wire repeaters one CFP761 network driver card required per system and optional CFP relay boardsSpace for two x 12V 3.3Ah VRLA batteries GBP 226.68 1
C-Tec CFP Two Wire 2 Zone AlarmSense Control Panel - CFP702-2 C-Tec CFP Two Wire 2 Zone AlarmSense Control Panel - CFP702-2C-TECs LPCB certified two-wire CFP AlarmSense fire panel is designed to work with Apollos AlarmSense range of detectors call points sounders and beacons. Most conventional fire systems are designed to work with two pairs of wires per zone one pair for detection devices such as smoke detectors heat detectors and manual call points the other for alarm devices such as bells sounders or strobes. By using different voltage bands for quiescent and alarm states AlarmSense components can be connected to the same pair of supply wires.When powered and controlled by the CFP two-wire fire panel this reliable technology takes all the complexity out of fire alarm system design leading to quicker less expensive and more flexible installation. Indeed research shows an AlarmSense two-wire system can achieve a 20-25 reduction of labour over a standard four wire conventional system. AlarmSense devices are acceptable for BS 5839-1 and BS 5839-6 systems making them particularly useful for fire protection in Houses of Multiple Occupation HMOs.Key FeaturesLPCB certified to EN54 parts 2 and 4Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry to access level 22 4 or 8 AlarmSense zone circuits dependent on model purchasedFour conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSUWide range of engineering functions including zone test coincidence zone delay and non- latching zonesTwo on-board relays Fire and FaultTwo open-collector outputs Remote and ResetClass change and alert inputsInstaller-friendly design accommodates easy first fix and straightforward maintenanceAttractive flush or surface mountable plastic lid and enclosure - no bezel requiredLow quiescent currentMultiple indicatorsEnd of line units included one per zoneAncillary system expansion connections provided for up to eight two-wire repeaters one CFP761 network driver card required per system and optional CFP relay boardsSpace for two x 12V 3.3Ah VRLA batteries GBP 182.66 1