C-Tec CFP708E-4M CFPE 8 Zone Motherboard - 4 Wire C-Tec CFP708E-4M CFPE 8 Zone Motherboard - 4 WireA CFPE 8 zone motherboard 4 wire. GBP 113.99 1
C-Tec CFP702-4M CFP 2 Zone Motherboard - 4 Wire C-Tec CFP702-4M CFP 2 Zone Motherboard - 4 WireA CFP 2 zone motherboard 4 wire. GBP 72.48 1
C-Tec CFP704-4M CFP 4 Zone Motherboard - 4 Wire C-Tec CFP704-4M CFP 4 Zone Motherboard - 4 WireA CFP 4 zone motherboard 4 wire. GBP 91.39 1
C-Tec CFP704-2M CFP 4 Zone Motherboard - 2 Wire C-Tec CFP704-2M CFP 4 Zone Motherboard - 2 WireA CFP 4 zone motherboard 2 wire. GBP 118.81 1
C-Tec CFP702E-4M CFPE 2 Zone Motherboard - 4 Wire C-Tec CFP702E-4M CFPE 2 Zone Motherboard - 4 WireA CFPE 2 zone motherboard 4 wire. GBP 62.99 1
C-Tec CFP702-2M CFP 2 Zone Motherboard - 2 Wire C-Tec CFP702-2M CFP 2 Zone Motherboard - 2 WireA CFP 2 zone motherboard 2 wire. GBP 94.24 1
C-Tec CFP708-4M CFP 8 Zone Motherboard - 4 Wire C-Tec CFP708-4M CFP 8 Zone Motherboard - 4 WireA CFP 8 zone motherboard 4 wire. GBP 138.67 1
C-Tec CFP704E-4M CFPE 4 Zone Motherboard - 4 Wire C-Tec CFP704E-4M CFPE 4 Zone Motherboard - 4 WireA CFPE 4 zone motherboard 4 wire. GBP 103.52 1
C-Tec CFP708-2M CFP 8 Zone Motherboard - 2 Wire C-Tec CFP708-2M CFP 8 Zone Motherboard - 2 WireA CFP 8 zone motherboard 2 wire. GBP 143.27 1
C-Tec CFP708-2 CFP Two Wire 8 Zone AlarmSense Control Panel C-Tec CFP Two Wire 8 Zone AlarmSense Control Panel - CFP708-2C-TECs LPCB certified two-wire CFP AlarmSense fire panel is designed to work with Apollos AlarmSense range of detectors call points sounders and beacons. Most conventional fire systems are designed to work with two pairs of wires per zone one pair for detection devices such as smoke detectors heat detectors and manual call points the other for alarm devices such as bells sounders or strobes. By using different voltage bands for quiescent and alarm states AlarmSense components can be connected to the same pair of supply wires.When powered and controlled by the CFP two-wire fire panel this reliable technology takes all the complexity out of fire alarm system design leading to quicker less expensive and more flexible installation. Indeed research shows an AlarmSense two-wire system can achieve a 20-25 reduction of labour over a standard four wire conventional system. AlarmSense devices are acceptable for BS 5839-1 and BS 5839-6 systems making them particularly useful for fire protection in Houses of Multiple Occupation HMOs.Key FeaturesLPCB certified to EN54 parts 2 and 4Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry to access level 22 4 or 8 AlarmSense zone circuits dependent on model purchasedFour conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSUWide range of engineering functions including zone test coincidence zone delay and non- latching zonesTwo on-board relays Fire and FaultTwo open-collector outputs Remote and ResetClass change and alert inputsInstaller-friendly design accommodates easy first fix and straightforward maintenanceAttractive flush or surface mountable plastic lid and enclosure - no bezel requiredLow quiescent currentMultiple indicatorsEnd of line units included one per zoneAncillary system expansion connections provided for up to eight two-wire repeaters one CFP761 network driver card required per system and optional CFP relay boardsSpace for two x 12V 3.3Ah VRLA batteries GBP 272.59 1
C-Tec CFP Two Wire 2 Zone AlarmSense Control Panel - CFP702-2 C-Tec CFP Two Wire 2 Zone AlarmSense Control Panel - CFP702-2C-TECs LPCB certified two-wire CFP AlarmSense fire panel is designed to work with Apollos AlarmSense range of detectors call points sounders and beacons. Most conventional fire systems are designed to work with two pairs of wires per zone one pair for detection devices such as smoke detectors heat detectors and manual call points the other for alarm devices such as bells sounders or strobes. By using different voltage bands for quiescent and alarm states AlarmSense components can be connected to the same pair of supply wires.When powered and controlled by the CFP two-wire fire panel this reliable technology takes all the complexity out of fire alarm system design leading to quicker less expensive and more flexible installation. Indeed research shows an AlarmSense two-wire system can achieve a 20-25 reduction of labour over a standard four wire conventional system. AlarmSense devices are acceptable for BS 5839-1 and BS 5839-6 systems making them particularly useful for fire protection in Houses of Multiple Occupation HMOs.Key FeaturesLPCB certified to EN54 parts 2 and 4Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry to access level 22 4 or 8 AlarmSense zone circuits dependent on model purchasedFour conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSUWide range of engineering functions including zone test coincidence zone delay and non- latching zonesTwo on-board relays Fire and FaultTwo open-collector outputs Remote and ResetClass change and alert inputsInstaller-friendly design accommodates easy first fix and straightforward maintenanceAttractive flush or surface mountable plastic lid and enclosure - no bezel requiredLow quiescent currentMultiple indicatorsEnd of line units included one per zoneAncillary system expansion connections provided for up to eight two-wire repeaters one CFP761 network driver card required per system and optional CFP relay boardsSpace for two x 12V 3.3Ah VRLA batteries GBP 182.66 1
C-Tec CFP704-2 CFP Two Wire 4 Zone AlarmSense Control Panel C-Tec CFP Two Wire 4 Zone AlarmSense Control Panel - CFP704-2C-TECs LPCB certified two-wire CFP AlarmSense fire panel is designed to work with Apollos AlarmSense range of detectors call points sounders and beacons. Most conventional fire systems are designed to work with two pairs of wires per zone one pair for detection devices such as smoke detectors heat detectors and manual call points the other for alarm devices such as bells sounders or strobes. By using different voltage bands for quiescent and alarm states AlarmSense components can be connected to the same pair of supply wires.When powered and controlled by the CFP two-wire fire panel this reliable technology takes all the complexity out of fire alarm system design leading to quicker less expensive and more flexible installation. Indeed research shows an AlarmSense two-wire system can achieve a 20-25 reduction of labour over a standard four wire conventional system. AlarmSense devices are acceptable for BS 5839-1 and BS 5839-6 systems making them particularly useful for fire protection in Houses of Multiple Occupation HMOs.Key FeaturesLPCB certified to EN54 parts 2 and 4Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry to access level 22 4 or 8 AlarmSense zone circuits dependent on model purchasedFour conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSUWide range of engineering functions including zone test coincidence zone delay and non- latching zonesTwo on-board relays Fire and FaultTwo open-collector outputs Remote and ResetClass change and alert inputsInstaller-friendly design accommodates easy first fix and straightforward maintenanceAttractive flush or surface mountable plastic lid and enclosure - no bezel requiredLow quiescent currentMultiple indicatorsEnd of line units included one per zoneAncillary system expansion connections provided for up to eight two-wire repeaters one CFP761 network driver card required per system and optional CFP relay boardsSpace for two x 12V 3.3Ah VRLA batteries GBP 226.68 1
C-Tec 24V 12.0 AHr VRLA Battery Pack BC2912 C-Tec 24V 12.0 AHr VRLA Battery Pack BC2912The BC2912 is a 24V 12.0 AHr VRLA battery pack 2 x 12V including link wire GBP 115.37 1
C-Tec 24V 24.0 AHr VRLA Battery Pack BC2892 C-Tec 24V 24.0 AHr VRLA Battery Pack BC2892The BC2892 is a 24V 24.0 AHr VRLA battery pack 2 x 12V including link wire. GBP 220.08 1
C-Tec CA408R CA Relay Base C-Tec CA408R CA Relay BaseThe CA408R CAST detector relay bases can only be used with C-Tecs range of CAST addressable detectors.The main feature of the CAST fire alarm systems is their ability to be able to run up to 255 devices per loop.Key FeaturesSupply Wiring 2 wire monitored polarity sensitiveIP Rating IP42 GBP 21.34 1
C-Tec CFP702PSU CFPXFP 28V 1.5A Switch Mode PSU C-Tec CFP702PSU CFPXFP 28V 1.5A Switch Mode PSUThe C-TEC CFP702PSU is a replacement internal power supplyfor C-TECs CFP range of fire alarm control panels.This part is for use with the following panels ranges-C-Tec CFP Conventional Fire Alarm Panels - 2 4 8 ZoneVersionsC-Tec CFP Alarmsense Two Wire Fire Alarm Panels - 2 4 8 Zone Versions GBP 60.43 1
C-Tec CFP Network Driver Card CFP761 C-Tec CFP Network Driver Card CFP761An optional system expansion device for use with CFP Standardand CFPAlarmSense conventional fire panels.This part must be used if you require the use of a repeater panel or you wish to network compatible XFP panels together.Key FeaturesAllows the connection of up to eight CFP760 Repeaters one CFP761 required per Main all CFP760 repeaters include a CFP761 as standardCommunicates over screened two-wire fire resistant cableTotal repeater network cable length should not exceed 1KM GBP 61.67 1
C-Tec ZFP Multi-Path Fault Tolerant Network PCB C-Tec ZFP Multi-Path Fault Tolerant Network PCBAllows the interconnection of up to 64 ZFP Main Panels any mix and up to 64 ZFP Compact Controllers over a two-wire RS485 ring-wired multi-path fault-tolerant Hi-Net network. One ZHN required per ZFP Main Panel ZFP Compact Controllers include a ZHN PCB as standard.Key FeaturesRS485 ProtocolMax. cable length between nodes 1KMMax. cable length of entire network 128KMFor retrofits multiple ZHNs can be wired in a non-fault tolerant single-path network configuration Max. 8 nodes Max length of entire network must not exceed 1KM. GBP 294.67 1
C-Tec CFP760 8 Zone Repeater Panel C-TecCFP7608Zone Repeater PanelCan be used to repeat the functions of a master CFP standard or AlarmSense 2-8 zone fire panel at remote parts of site e.g. all potential fire service entrances.Key FeaturesUp to 8 repeaters per CFP masterIncludes its own Mains power supply that requires its own standby battery supplyProvides the user with access to all AL1 and AL2 functionsMasterRepeater communication achieved using CFP761 network driver cards one CFP761 is supplied with the Repeater an additional CF761 card is required at the master CFPCommunicates over screened two-wire fire resistant cableTotal repeater network cable length should not exceed 1KMAttractive flush or surface mountable plastic lid and enclosure - no bezel required GBP 184.55 1
C-Tec AFP711 XFP Network Communications Card C-Tec AFP711 XFP Network Communications CardAn optional system expansion device for use with XFP 12 Loop 32 Zone fire panels. Allowsthe connection of up to eight XFP Repeaters or eight XFP Main panels any mix on an RS485 network. One AFP711 card required per networked Main XFP 12 Loop 32 Zone panel note that XFP510-16 and XFP510-32 repeaters include a network driver card as standard.The AFP711 is NOT compatible with XFP Single Loop 16 Zone panels which require a CFP761 card for networking.Key network protocol features when used for interconnecting XFP main panelsCan be used to connect up to 8 XFP main panels any mix over a two-wire RS485 network of up to 1KM in length.Each networked XFP can be programmed to accept Fires Faults and Control actions such as Silence Alarm Sounders and Control Panel Resets from other panels.Each XFP will accept Disablement commands for zones sounders and output sets from other panels.All panels monitored for network wiring faults.Fires and faults on remote panels are displayed on local panels including the point description.CEs can be programmed into local panels dependent on which remote panel is in alarm.The network supports the programming of site data into remote panels from a PC at a local panel.Time and date is common to all panels.All networked main panels require a network communication card.It is not possible to mix XFP main panels and XFP repeaters on the same network.Key network protocol features when used for connecting XFP repeatersCan be used to connect up to 8 XFP repeaters any mix to one XFP main panel.Up to 500m of cable may be fitted to an XFP two-wire repeater network.Each XFP repeater offers all the functions and controls of an XFP main panel.The XFP main panel must have a network communication card fitted.It is not possible to mix XFP main panels and XFP repeaters on the same network. GBP 114.65 1
C-Tec XFP761 XFP Network Card For 16 Zone Panels C-Tec XFP761 XFP Network Card For 16 Zone PanelsThe XFP network card allows for the connection of up to eight mainpanels any mix over a two-wire RS485 network spanning up to 1KM. Eachnetworked XFP panel can be programmed to receive fire alerts faults andcontrol commands such as silencing alarm sounders and resetting controlpanels from other connected panels.Key FeaturesCan be used to connect up to 8 XFP repeaters any mix toone XFP main panelUp to 500m of cable may be fitted to an XFP two-wirerepeater networkEach XFP repeater offers all the functions and controls ofan XFP main panelThe XFP main panel must have a network communication cardfittedIt is not possible to mix XFP main panels and XFP repeaterson the same networkOne XFP761 required per networked Main XFP Single Loop 16Zone fire panel note that XFP510-16 and XFP510-32 repeaters include a networkdriver card as standardThe XFP761 is NOT compatible with XFP 12 Loop32 Zone fire panels which require an AFP711 card for networking GBP 74.52 1
C-Tec MTL7787 HOC Zener Barrier C-Tec MTL7787 HOC Zener BarrierSince its introduction in 1984 the MTL700 range has established itself as the worldwide standard for safety barriers. Known for its quality and reliability the MTL700 range is widely used in applications all over the world.The MTL7700 range follows closely in the footsteps of the MTL700 but as a DIN rail mounting barrier providing quick and easy installation without the need for special hardware.Removable terminals are used for ease of installation maintenance and for providing a loop disconnect by simply unplugging the terminals from the side of the module. Wire entry is also angled to assist wiring within limited space enclosures.MTL7700 barriers clamp simply and securely onto standard T-section DIN rail simultaneously making a reliable IS earth connection.Key FeaturesRemovable terminalsBussed power feed to other modulesRelay and solid state switch modulesDual channel variants 6.3mm per channelProximity detector inputsElectronic fusingDirect replacement for MTL700 range barrierCompatible terminal numbering and safety descriptionsPlease note This image is for illustrative purposes only. You will receive 1 xC-Tec MTL7787 HOC Zener Barrier. GBP 119.88 1
C-Tec CFP 4 Zone Conventional Fire Panel LPCB Approved - CFP704-4 C-Tec CFP 4 Zone Conventional Fire Panel LPCB Approved - CFP704-4LPCB certified to EN54-24 C-TECs CFP 4 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price. Supplied in an attractive flush or surface mountable plastic enclosure it includes two detector zones four conventional sounder circuits class change and alert inputs on-board fire and fault relays and combined keypadkey switch entry.A wide range of engineering functions are also provided including selectable zone delays coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided. Optional repeaters relay expansion boards and EN54-13 system compliance devices are also available.Key FeaturesThird-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board LPCB with optional EN54 part 13 compliance from the BSI.Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry.Manufactured by C-TEC in the UK.Two detector zone circuits.Four conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSU.Wide range of engineering functions including zone test coincidence zone delay and non-latching zones.Two on-board relays Fire and Fault.Two open-collector outputs Remote and Reset.Class change and alert inputs.Installer-friendly design.Attractive flush or surface mountable plastic lid and enclosure - no bezel required.Low 25mA quiescent current.Multiple indicators.System expansion connections provided for up to eight two-wire repeaters one CFP761 network card required per system optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.Space for two x 12V 3.3Ah VRLA batteries.Fully compatible with C-TECs ActiV range of conventional fire detectors. GBP 148.46 1
C-Tec CFP702-4 2 Zone Conventional Fire Panel LPCB Approved C-Tec CFP 2 Zone Conventional Fire Panel LPCB Approved - CFP702-4LPCB certified to EN54-24 C-TECs CFP 2 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price. Supplied in an attractive flush or surface mountable plastic enclosure it includes two detector zones four conventional sounder circuits class change and alert inputs on-board fire and fault relays and combined keypadkey switch entry.A wide range of engineering functions are also provided including selectable zone delays coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided. Optional repeaters relay expansion boards and EN54-13 system compliance devices are also available.Key FeaturesThird-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board LPCB with optional EN54 part 13 compliance from the BSI.Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry.Manufactured by C-TEC in the UK.Two detector zone circuits.Four conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSU.Wide range of engineering functions including zone test coincidence zone delay and non-latching zones.Two on-board relays Fire and Fault.Two open-collector outputs Remote and Reset.Class change and alert inputs.Installer-friendly design.Attractive flush or surface mountable plastic lid and enclosure - no bezel required.Low 25mA quiescent current.Multiple indicators.System expansion connections provided for up to eight two-wire repeaters one CFP761 network card required per system optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.Space for two x 12V 3.3Ah VRLA batteries.Fully compatible with C-TECs ActiV range of conventional fire detectors. GBP 130.25 1
C-Tec CFP708-4 8 Zone Conventional Fire Panel LPCB Approved C-Tec CFP 8 Zone Conventional Fire Panel LPCB Approved - CFP708-4LPCB certified to EN54-24 C-TECs CFP 8 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price. Supplied in an attractive flush or surface mountable plastic enclosure it includes two detector zones four conventional sounder circuits class change and alert inputs on-board fire and fault relays and combined keypadkey switch entry.A wide range of engineering functions are also provided including selectable zone delays coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided. Optional repeaters relay expansion boards and EN54-13 system compliance devices are also available.Key FeaturesThird-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board LPCB with optional EN54 part 13 compliance from the BSI.Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry.Manufactured by C-TEC in the UK.Two detector zone circuits.Four conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSU.Wide range of engineering functions including zone test coincidence zone delay and non-latching zones.Two on-board relays Fire and Fault.Two open-collector outputs Remote and Reset.Class change and alert inputs.Installer-friendly design.Attractive flush or surface mountable plastic lid and enclosure - no bezel required.Low 25mA quiescent current.Multiple indicators.System expansion connections provided for up to eight two-wire repeaters one CFP761 network card required per system optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.Space for two x 12V 3.3Ah VRLA batteries.Fully compatible with C-TECs ActiV range of conventional fire detectors. GBP 208.82 1