Baldwin Boxall Omnicare Type A Red Fire Telephone with Lock Door BVOCFL Baldwin Boxall Omnicare Type A Red Fire Telephone with Lock Door BVOCFLThe OmniCare system offers a choice of outstation units which can be wired on the same loop from the control panel. The BVOCFL red fire telephone unit is one of the options available on this versatile system.Fire telephones are used by fire officers and those responsible for the evacuation of a building during an emergency. They provide essential communication for those in control. When operated by opening the door of the enclosure the persons managing the evacuation at the control panel can immediately see the location of the caller as this is indicated on the panel. The fire officer at the telephone point can relay the situation and confirm if that area is clear of personnelpublic before moving to the next levelarea.The fire telephone is connected to the control panel in a loop circuit and can be included with disabled refuge outstations on the same panel if these are required. As an option the Omnicare system also has a combined outstation which includes both a fire telephone and a disabled refuge unit in the same enclosure.Key FeaturesProvides two-way full duplex speech communication.Self-powered from ring circuit no local power source is required. Automatic battery backup is provided by the control panel in the event of a mains power failure.Red finish also available in stainless steel BVOCFSL.Slot lock door push catch version available BVOCF.Addressable unit.The enclosure contains a rugged red handset with hearing aid compatible earpiece and loudspeaker.Calls are initiated upon opening the door. When answered the user can talk to the operator either by lifting the handset or hands-free. Closing the door ends the call.Conference call facility between multiple fire telephones is available via the operator at the control panel.All outstations are in a loop circuit from control panels.Surface mountable or flush mount with optional bezel. GBP 576.98 1
Baldwin Boxall RPP1 Protective Cover for RVPS Baldwin Boxall RPP1 Protective Cover for RVPSThe RVPS Room Panel can be fitted with a robust brushed Stainless Steel cover to protect the controls when not in use. The RPP1 has been designed for the RVPS and is an optional cover for the RVPS.It should be mounted in between the backbox and the front panel of the RPVS and secured with the two mounting screws.Key FeaturesDimensions H 94mm W 91mm D 25mmWeight 0.25KgMaterial Stainless SteelOptional coverPlease note The image is for illustrative purposes only. The RPP1 does not come with the RVPS included. GBP 209.57 1
Baldwin Boxall RPP2 Protective Cover for RPAIV Baldwin Boxall RPP2 Protective Cover for RPAIVThe RPAIV Room Panel can be fitted with a robust brushed Stainless Steel cover to protect the controls when not in use. The RPP2 has been designed for the RPAIV and is an optional cover for the RPAIV.It should be mounted in between the backbox and the front panel of the RPAIV and secured with the two mounting screws.Key FeaturesDimensions H 94mm W 151mm D 25mmWeight 0.38KgMaterial Stainless SteelOptional coverPlease note The image is for illustrative purposes only. The RPP2 does not come with the RPAIV included. GBP 56.24 1
Baldwin Boxall Omnicare Type A Red Fire Telephone with Push Door BVOCF Baldwin Boxall Omnicare Type A Red Fire Telephone with Push Door BVOCFThe OmniCare system offers a choice of outstation units which can be wired on the same loop from the control panel. The BVOCF red fire telephone unit is one of the options available on this versatile system.Fire telephones are used by fire officers and those responsible for the evacuation of a building during an emergency. They provide essential communication for those in control. When operated by opening the door of the enclosure the persons managing the evacuation at the control panel can immediately see the location of the caller as this is indicated on the panel. The fire officer at the telephone point can relay the situation and confirm if that area is clear of personnelpublic before moving to the next levelarea.The fire telephone is connected to the control panel in a loop circuit and can be included with disabled refuge outstations on the same panel.Key FeaturesProvides two-way full duplex speech communication.Self-powered from ring circuit no local power source is required. Automatic battery backup is provided by the control panel in the event of a mains power failure.Red finish also available in stainless steel BVOCFS.Push catch door slot lock version available BVOCFL.Addressable unit.The enclosure contains a rugged red handset with hearing aid compatible earpiece and loudspeaker.Calls are initiated upon opening the door. When answered the user can talk to the operator either by lifting the handset or hands-free. Closing the door ends the call.Conference call facility between multiple fire telephones is available via the operator at the control panel.All outstations are in a loop circuit from control panels.Surface mountable or flush mount with optional bezel. GBP 540.70 1
Baldwin Boxall Omnicare Type A Stainless Steel Fire Telephone with Lock Door BVOCFSL Baldwin Boxall Omnicare Type A Stainless Steel Fire Telephone with Lock Door BVOCFSLThe OmniCare system offers a choice of outstation units which can be wired on the same loop from the control panel. The BVOCFSL fire telephone unit with stainless steel finish is one of the options available on this versatile system.Fire telephones are used by fire officers and those responsible for the evacuation of a building during an emergency. They provide essential communication for those in control. When operated by opening the door of the enclosure the persons managing the evacuation at the control panel can immediately see the location of the caller as this is indicated on the panel. The fire officer at the telephone point can relay the situation and confirm if that area is clear of personnelpublic before moving to the next levelarea.The fire telephone is connected to the control panel in a loop circuit and can be included with disabled refuge outstations on the same panel if these are required. As an option the Omnicare system also has a combined outstation which includes both a fire telephone and a disabled refuge unit in the same enclosure.Key FeaturesProvides two-way full duplex speech communication.Self-powered from ring circuit no local power source is required. Automatic battery backup is provided by the control panel in the event of a mains power failure.Stainless steel finish also available in red BVOCFL.Slot lock door push catch version available BVOCFS.Addressable unit.The enclosure contains a rugged red handset with hearing aid compatible earpiece and loudspeaker.Calls are initiated upon opening the door. When answered the user can talk to the operator either by lifting the handset or hands-free. Closing the door ends the call.Conference call facility between multiple fire telephones is available via the operator at the control panel.All outstations are in a loop circuit from control panels.Surface mountable or flush mount with optional bezel.Please note Stainless steel products are not intended for installation in humid areas. GBP 799.25 1
Baldwin Boxall Omnicare Type A Stainless Steel Fire Telephone with Push Door BVOCFS Baldwin Boxall Omnicare Type A Stainless Steel Fire Telephone with Push Door BVOCFSThe OmniCare system offers a choice of outstation units which can be wired on the same loop from the control panel. The BVOCFS fire telephone unit with stainless steel finish is one of the options available on this versatile system.Fire telephones are used by fire officers and those responsible for the evacuation of a building during an emergency. They provide essential communication for those in control. When operated by opening the door of the enclosure the persons managing the evacuation at the control panel can immediately see the location of the caller as this is indicated on the panel. The fire officer at the telephone point can relay the situation and confirm if that area is clear of personnelpublic before moving to the next levelarea.The fire telephone is connected to the control panel in a loop circuit and can be included with disabled refuge outstations on the same panel if these are required. As an option the Omnicare system also has a combined outstation which includes both a fire telephone and a disabled refuge unit in the same enclosure.Key FeaturesProvides two-way full duplex speech communication.Self-powered from ring circuit no local power source is required. Automatic battery backup is provided by the control panel in the event of a mains power failure.Stainless steel finish also available in red BVOCF.Push catch door slot lock version available BVOCFSL.Addressable unit.The enclosure contains a rugged red handset with hearing aid compatible earpiece and loudspeaker.Calls are initiated upon opening the door. When answered the user can talk to the operator either by lifting the handset or hands-free. Closing the door ends the call.Conference call facility between multiple fire telephones is available via the operator at the control panel.All outstations are in a loop circuit from control panels.Surface mountable or flush mount with optional bezel.Please note Stainless steel products are not intended for installation in humid areas. GBP 762.05 1
Baldwin Boxall Line Vox Unit BT10 Baldwin Boxall Line Vox Unit BT10The BT10 is a universal interface module. Connect the input of the BT10 to either a 100 Volt loudspeaker line or the line level output from a telephone switch.The output at either microphone or line level can be fed into an amplifier. When a signal of a sufficient level is received at the input the Vox circuit will operate and it will be passed via the output into the amplifier.In addition the unit has a switched 0V available on the ACC terminal to access the amplifier. E.G. When using one of our amplifiers take a connecting wire from the ACC terminal to pin 5 on the appropriate input socket.The Vox circuit is designed to ensure that there will not be any unwanted noise appearing at the amplifier input and being relayed through the loudspeakers.A pre-set control allows adjustment of the Vox sensitivity. To set it adjust the control so that it only switches on when a suitable signal level is present.The TEST LED will illuminate when the Vox has operated and the access will be switched ON. The gain pre-set adjusts the gain of the unit and is factory pre-set at x 2 6 dB.It can be used to compensate for different input signal levels. The unit is powered from either mains or 24 VDC.If both are connected in the event of mains failure there will be automatic switch over to the 24VDC and the unit will continue to operate. GBP 381.02 1
Baldwin Boxall CARE2 Fire Panel Ethernet Module C2CFPE Baldwin Boxall CARE2 Fire Panel Ethernet Module C2CFPEAs supplied the Care2 system is permanently active and all DRS Refuge Remotes are able to make calls all the time. The C2CFPE Fire Panel Interface card enables the DRS Refuge Remotes to be active only when a Fire Panel is active. The Interface Card also provides the Common Fault Volt Free contacts and the Ethernet contacts. GBP 86.18 1
Baldwin Boxall Omnicare Fire Tel Red Lock Door CW Beacon BVOCFLB Baldwin Boxall Omnicare Fire Tel Red Lock Door CW Beacon BVOCFLBFire telephones are used by fire officers and those responsible for the evacuation of a building during an emergency. They provide essential communication for those in control. When operated by opening the door of the enclosure the persons managing the evacuation at the control panel can immediately see the location of the caller as this is indicated on the panel. The fire officer at the telephone point can relay the situation and confirm if that area is clear of personnelpublic before moving to the next levelarea.The fire telephone is connected to the control panel in a loop circuit and can be included with disabled refuge outstations on the same panel if these are required. As an option the Omnicare system also has acombined outstationwhich includes both a fire telephone and a disabled refuge unit in the same enclosure.Other outstations available include steward telephones and disabled toilet alarms.Omnicare fire telephones are powered from the ring circuit and have the following featuresRed or stainless-steel finishRugged red handset with T-Coil hearing aid compatible earpiece and loudspeakerHands free useFull duplex speech digital audioDoor latch initiates callPush catch or slot lockable door andor beaconConference facility via master control panelSurface mountable optional flush mount bezel availableWired in aloop configurationusing fire rated enhanced four-core cable GBP 677.68 1
Baldwin Boxall DC Line Monitor BVRDADC Baldwin Boxall DC Line Monitor BVRDADCThe Vigil BVRDADC is a loudspeaker line monitor and amplifier changeover unit for use with VIGIL amplifiers and the BVRD2M router. Each unit is supplied as a DIN rail-mounting module with screw terminals for connections to the amplifiers and loudspeaker lines. Connection to the BVRD2M is by CAN BUS ports. Each unit consists of ten channels that can be utilised for either dual or single circuit systems.For dual circuits ten working amplifiers five dual circuits and one standby amplifier can be accommodated. For single circuit systems ten working amplifiers ten single circuits and one standby amplifier are available. If an amplifier were to fail the BVRDADC automatically detects the faulty amplifier and switches over to a reserve amplifier until the fault has been rectified. A fault will be displayed on the BVRD2M front panel and also stored in the BVRD2M fault log.When the faulty amplifier has been replaced it is necessary to press the Fault Reset button on the front of the BVRD2M to restore the system and stop using the reserve amplifier. Each loudspeaker line including spurs must have an End of Line resistor fitted in parallel with the last physical loudspeaker on the line. All loudspeakers must be fitted with a DC Blocking capacitor. The BVRDADC monitors the integrity of the Loudspeaker Line by measuring a small DC current flowing through the End of Line resistors. Any change in this current indicates either a short circuit or open circuit condition on the loudspeaker line. Earth faults are also detected. GBP 1449.71 1
Baldwin Boxall VIGIL2 225W Class D Amplifier BV225 Baldwin Boxall VIGIL2 225W Class D Amplifier BV225The BV225 Amplifier module is a 225-Watt Class D Power amplifier with a 500mV Balance Line audio input and 100V Line output. The front panel status indicators show Power Overload and Output Level 10 and 100 output level. The audio input is presented on two separate RJ45 connectors. The output is presented on two 3-way plugcage clamp termination connectors providing 50V or 100V output. The 24V DC input is presented on a two 2-way crimp connected socket.The power output stage of the amplifier is protected against overload conditions i.e. short circuits or abnormal loads. Should an amplifier be subjected to an abnormal load the input to the relevant power amplifier is attenuated to a safe level and the Overload LED will be illuminated. The amplifier output voltages are also sensed and should they exceed 100V the relevant input signal will be attenuated ensuring safe operation without creating unnecessary distortion.Over temperature protection is provided using sensors attached to the output stage heat sink. Should the temperature exceed 90 Degrees Celsius the input signal to the relevant amplifier will be attenuated to a safe level and the Overload LED will be illuminated. If the system is under surveillance it will cause the surveillance detector to indicate a fault condition due to the gain reduction. GBP 870.91 1
Baldwin Boxall Omnicare Emergency Tel Green Push Door CW Beacon BVOCETB Baldwin Boxall Omnicare Emergency Tel Green Push Door CW Beacon BVOCETBThe Omnicare system offers a choice of outstation units which can be wired on the same loop from the control panel.The BVOCET emergencysteward telephone unit is one of the options available on this versatile system.Key FeaturesProvides two-way full duplex speech communication.Self-powered from ring circuit no local power source is required. Automatic battery backup is provided by the control panel in the event of a mains power failure.Green finish.With additional beacon BVOCETB.Push catch door slot lock version available BVOCETL.Addressable unit.The enclosure contains a rugged red handset with hearing aid compatible earpiece and loudspeaker.Calls are initiated upon opening the door. When answered the user can talk to the operator either by lifting the handset or hands-free. Closing the door ends the call.Conference call facility between multiple steward telephones is available via the operator at the control panel.All outstations are in a loop circuit from control panels.Surface mountable or flush mount with optional bezel. GBP 622.34 1
Baldwin Boxall Omnicare Emergency Tel Green Lock Door CW Beacon BVOCETLB Baldwin Boxall Omnicare Emergency Tel Green Lock Door CW Beacon BVOCETLBThe Omnicare system offers a choice of outstation units which can be wired on the same loop from the control panel.The BVOCET emergencysteward telephone unit is one of the options available on this versatile system.Key FeaturesProvides two-way full duplex speech communication.Self-powered from ring circuit no local power source is required. Automatic battery backup is provided by the control panel in the event of a mains power failure.Green finish.With additional beacon BVOCETB.Push catch door slot lock version available BVOCETL.Addressable unit.The enclosure contains a rugged red handset with hearing aid compatible earpiece and loudspeaker.Calls are initiated upon opening the door. When answered the user can talk to the operator either by lifting the handset or hands-free. Closing the door ends the call.Conference call facility between multiple steward telephones is available via the operator at the control panel.All outstations are in a loop circuit from control panels.Surface mountable or flush mount with optional bezel. GBP 711.24 1
Baldwin Boxall VIGIL2 Quad 50W Class D Amplifier BV050Q Baldwin Boxall VIGIL2 Quad 50W Class D Amplifier BV050QThe Vigil2 BV050Q contains four independent 50 Watt Class D Power amplifiers each with one 500 mV balanced input and a 50 Watt 100V Line output. The front panel status indicators show Supply Healthy Overload Over Temperature and Output Level 10 and 100 max output level for each amplifier. The Active Indicator illuminates when the amplifier is not in Sleep Mode. CLASS D amplifiers are 80 efficient therefore reducing unwanted heat dissipation and power input requirements. Rated output power is obtainable using a 22V battery supply.The BV050Q has a Sleep mode automatically reducing the standby current requirement to typically 50mA per amplifier when operating on batteries. Channel gain may be individually set using the potentiometers on the board behind the front panel. The audio inputs to the amplifiers are presented on separate RJ45 connectors each connector providing the balanced audio input and a ground connection. The outputs are presented on 6-way plugscrew termination connectors providing 50V or 100V output. The 24V DC input is presented on a 2-way crimp connected plug and socket. The power output stage of the amplifier is protected against overload conditions i.e. short circuits or abnormal loads etc. Should the amplifier be subjected to an abnormal load the input to the power amplifier is attenuated to a safe level.The amplifiers output voltage is also sensed and should it exceed 100V the input signal will be attenuated ensuring safe operation without creating unnecessary distortion. Over temperature protection is provided using a sensor attached to the output stage heat sink. Should the temperature exceed 90 Degrees Celsius the input signal to will be attenuated to a safe level and the Overtemp LED will be illuminated. If the system is under surveillance it will cause the surveillance detector to indicate a fault condition due to the gain reduction. Up to three BV050Q Amplifier modules may be mounted in one BVMF equipment frame or more normally two amplifier modules and one switched mode power supply charger module. GBP 1973.16 1
Baldwin Boxall Omnicare Fire Tel Red Push Door CW Beacon BVOCFB Baldwin Boxall Omnicare Fire Tel Red Push Door CW Beacon BVOCFBThe Omnicare system offers a choice of outstation units which can be wired on the same loop from the control panel. The BVOCF red fire telephone unit is one of the options available on this versatile system.Key FeaturesProvides two-way full duplex speech communication.Self-powered from ring circuit no local power source is required. Automatic battery backup is provided by the control panel in the event of a mains power failure.Red finish also available in stainless steel BVOCFS.With additional beacon BVOCFB.Push catch door slot lock version available BVOCFL.Addressable unit.The enclosure contains a rugged red handset with hearing aid compatible earpiece and loudspeaker.Calls are initiated upon opening the door. When answered the user can talk to the operator either by lifting the handset or hands-free. Closing the door ends the call.Conference call facility between multiple fire telephones is available via the operator at the control panel.All outstations are in a loop circuit from control panels.Surface mountable or flush mount with optional bezel. GBP 604.20 1
Baldwin Boxall 1 Zone Paging Telephone Interface BT5 Baldwin Boxall 1 Zone Paging Telephone Interface BT5Our telephone interface units enable staff to make public address announcements from their own desk telephone. The free-standing units act as an interface between the analogue telephone system and the amplifier.Key FeaturesOperated by simply dialling the BT5BT8 extension number.Each unit is supplied with an IEC mains lead.Connect to a telephone extension socket and the public address amplifier.Fully approved by BT approval number S24553H452969.The BT5 will provide the user with an acknowledge tone followed by a chime optional OPT33 fitted. A live broadcast announcement can then be made.Upon completion of the broadcast the BT5 will disconnect from the PA system and release the telephone extension ready to accept another call.Outputs are selectable from line or microphone level.Priority level control available. GBP 617.81 1
Baldwin Boxall 100W Volume Controls with Override Relay BVC100 Baldwin Boxall 100W Volume Controls with Override Relay BVC100These volume controls are designed to attenuate the signal fed to loudspeakers driven by the 100-volt line output of a public address amplifier. The volume control is fitted into a double gang surface mounting box and can be used with any number of loudspeakers provided the load does not exceed 100 Watts. The control has 9 steps of 3dB. The knob is fully rotating. A volume restoration relay is fitted and operates in the same way as the BVC6. GBP 219.54 1
Baldwin Boxall Ambient Noise Weatherproof Sensor BVRAMBIP Baldwin Boxall Ambient Noise Weatherproof Sensor BVRAMBIPWhen designing a voice alarm system for areas of variable levels of ambient noise which could cause problems with audibility noise sensors should be included. Correctly placed ambient noise sensors will ensure that all announcements are clearly heard.Key FeaturesTwo versions are available BVRAMB - standard version. BVRAMBIP - IP65 rated version.Monitors the ambient noise in a given area.Automatically adjusts the power of the amplifiers depending on noise level.When the area is at its quietest the level of the announcements or music will reduce.During busynoisy periods the volume level adjusts to suit.Used in conjunction with a BVRDCI CANBUS interface module which connects to the VIGIL EVAS routers.Uses a dynamic microphone capsule the output of which is amplified and converted to produce a variable current.This output is used by the BVRDCI module to produce a voltage that is proportional to the ambient noise.Band pass filtering ensures that the system only responds to ambient noise affecting the intelligibility of announcements.An on-board surveillance tone generator permanently monitors the microphone capsule. A system fault will be indicated should the microphone capsule or on-board amplifier fail.The BVRAMB includes an option to allow one of three response speeds to be selected SLOW - the system will only respond to an average change of ambient noise. MEDIUM - suitable for most installations. FAST - the system will react to short duration changes in ambient noise.Two units can be wired in parallel on the same input to monitor the ambient noise over a larger area. GBP 530.71 1
Baldwin Boxall Ambient Noise Sensor BVRAMB Baldwin Boxall Ambient Noise Sensor BVRAMBWhen designing a voice alarm system for areas of variable levels of ambient noise which could cause problems with audibility noise sensors should be included. Correctly placed ambient noise sensors will ensure that all announcements are clearly heard.Key FeaturesTwo versions are available BVRAMB - standard version. BVRAMBIP - IP65 rated version.Monitors the ambient noise in a given area.Automatically adjusts the power of the amplifiers depending on noise level.When the area is at its quietest the level of the announcements or music will reduce.During busynoisy periods the volume level adjusts to suit.Used in conjunction with a BVRDCI CANBUS interface module which connects to the VIGIL EVAS routers.Uses a dynamic microphone capsule the output of which is amplified and converted to produce a variable current.This output is used by the BVRDCI module to produce a voltage that is proportional to the ambient noise.Band pass filtering ensures that the system only responds to ambient noise affecting the intelligibility of announcements.An on-board surveillance tone generator permanently monitors the microphone capsule. A system fault will be indicated should the microphone capsule or on-board amplifier fail.The BVRAMB includes an option to allow one of three response speeds to be selected SLOW - the system will only respond to an average change of ambient noise. MEDIUM - suitable for most installations. FAST - the system will react to short duration changes in ambient noise.Two units can be wired in parallel on the same input to monitor the ambient noise over a larger area. GBP 313.90 1
Baldwin Boxall Chime Card for IMPX OPT33 Baldwin Boxall Chime Card for IMPX OPT33BT5 unitThe BT5 will provide the user an acknowledge tone followed by a chime optional OPT33 fitted. A live broadcast announcement can then be made.Upon completion of the broadcast the BT5 will disconnect from the PA system and release the telephone extension ready to accept another call. GBP 81.65 1
Baldwin Boxall Omnicare Combined Stainless Steel Disabled Refuge Unit with Push Door BVOCCSP Baldwin Boxall Omnicare Combined Stainless Steel Disabled Refuge Unit with Push Door BVOCCSPThe combined unit for the Omnicare Loop-wired EVC system provides two types of call point at one location. This unit was the first of its kind on the market and has been installed in many locations worldwide.The Omnicare combined outstation has been specially designed so that it can be installed in such a way as to enable correct mounting heights for each section of the unit as laid out in BS5839-9. The combined unit can be placed on the wiring loop in combination with any other Omnicare style outstation providing users great flexibility and choice.Key FeaturesSelf-powered from ring circuit no local power source is required. Automatic battery backup is provided by the control panel in the event of a mains power failure.Stainless steel finish also available in red BVOCC.Push catch door.Addressable unit.Surface mount or flush mount with optional bezel.All outstations are in a loop circuit from control panels.Fire telephone Provides two-way full duplex speech communication.The fire telephone section contains a rugged red handset with hearing aid compatible earpiece and loudspeaker.Calls are initiated upon opening the door. When answered the user can talk to the operator either by lifting the handset or hands-free. Closing the door ends the call.Conference call facility between multiple fire telephones is available via the operator at the control panel.Disabled refuge remote Provides two-way hands free speech steered communication.Volt free contact active when occupied. To operate over-door lamps silence speakersounder etc.Stainless steel press to call button.Calls can be reset either by of the key-switch on the remote unit or at the master control panel.Option to be permanently active if required.Reset from either remote unit using the key switch or via the master control panel.Please note Stainless steel products are not intended for installation in humid areas. GBP 1041.47 1
Baldwin Boxall Omnicare Combined Disabled Refuge Unit with Lock Door BVOCCL Baldwin Boxall Omnicare Combined Disabled Refuge Unit with Lock Door BVOCCLThe combined unit for the Omnicare LOOP-wired EVC system provides two types of call point at one location. This unit was the first of its kind on the market and has been installed in many locations worldwide.The Omnicare combined outstation has been specially designed so that it can be installed in such a way as to enable correct mounting heights for each section of the unit as laid out in BS5839-9. The combined unit can be placed on the wiring loop in combination with any other Omnicare style outstation providing users great flexibility and choice.Key FeaturesSelf-powered from ring circuit no local power source is required. Automatic battery backup is provided by the control panel in the event of a mains power failure.Red finish also available in stainless steel BVOCCS.Slot lock door.Addressable unit.Surface mount or flush mount with optional bezel.All outstations are in a loop circuit from control panels.Fire telephone Features Provides two-way full duplex speech communication.The fire telephone section contains a rugged red handset with hearing aid compatible earpiece and loudspeaker.Calls are initiated upon opening the door. When answered the user can talk to the operator either by lifting the handset or hands-free. Closing the door ends the call.Conference call facility between multiple fire telephones is available via the operator at the control panel.Disabled refuge remote Provides two-way hands free speech steered communication.Volt free contact active when occupied. To operate over-door lamps silence speakersounder etc.Stainless steel press to call button.Calls can be reset either by of the key-switch on the remote unit or at the master control panel.Option to be permanently active if required.Reset from either remote unit using the key switch or via the master control panel. GBP 886.33 1
Baldwin Boxall Omnicare Combined Disabled Refuge Unit with Push Door BVOCC Baldwin Boxall Omnicare Combined Disabled Refuge Unit with Push Door BVOCCThe combined unit for the Omnicare Loop-wired EVC system provides two types of call point at one location. This unit was the first of its kind on the market and has been installed in many locations worldwide.The Omnicare combined outstation has been specially designed so that it can be installed in such a way as to enable correct mounting heights for each section of the unit as laid out in BS5839-9. The combined unit can be placed on the wiring loop in combination with any other Omnicare style outstation providing users great flexibility and choice.Key FeaturesSelf-powered from ring circuit no local power source is required. Automatic battery backup is provided by the control panel in the event of a mains power failure.Red finish also available in stainless steel BVOCCS.Push catch door.Addressable unit.Surface mount or flush mount with optional bezel.All outstations are in a loop circuit from control panels.Fire telephone Features Provides two-way full duplex speech communication.The fire telephone section contains a rugged red handset with hearing aid compatible earpiece and loudspeaker.Calls are initiated upon opening the door. When answered the user can talk to the operator either by lifting the handset or hands-free. Closing the door ends the call.Conference call facility between multiple fire telephones is available via the operator at the control panel.Disabled refuge remote Provides two-way hands free speech steered communication.Volt free contact active when occupied. To operate over-door lamps silence speakersounder etc.Stainless steel press to call button.Calls can be reset either by of the key-switch on the remote unit or at the master control panel.Option to be permanently active if required.Reset from either remote unit using the key switch or via the master control panel. GBP 876.36 1
Baldwin Boxall Omnicare Combined Stainless Steel Disabled Refuge Unit with Lock Door BVOCCSL Baldwin Boxall Omnicare Combined Stainless Steel Disabled Refuge Unit with Lock Door BVOCCSLThe combined unit for the Omnicare Loop-wired EVC system provides two types of call point at one location. This unit was the first of its kind on the market and has been installed in many locations worldwide.The Omnicare combined outstation has been specially designed so that it can be installed in such a way as to enable correct mounting heights for each section of the unit as laid out in BS5839-9. The combined unit can be placed on the wiring loop in combination with any other Omnicare style outstation providing users great flexibility and choice.Key FeaturesSelf-powered from ring circuit no local power source is required. Automatic battery backup is provided by the control panel in the event of a mains power failure.Stainless steel finish also available in red BVOCC.Slot lock door.Addressable unit.Surface mount or flush mount with optional bezel.All outstations are in a loop circuit from control panels.Fire telephone Provides two-way full duplex speech communication.The fire telephone section contains a rugged red handset with hearing aid compatible earpiece and loudspeaker.Calls are initiated upon opening the door. When answered the user can talk to the operator either by lifting the handset or hands-free. Closing the door ends the call.Conference call facility between multiple fire telephones is available via the operator at the control panel.Disabled refuge remote Provides two-way hands free speech steered communication.Volt free contact active when occupied. To operate over-door lamps silence speakersounder etc.Stainless steel press to call button.Calls can be reset either by of the key-switch on the remote unit or at the master control panel.Option to be permanently active if required.Reset from either remote unit using the key switch or via the master control panel.Please note Stainless steel products are not intended for installation in humid areas. GBP 1071.41 1
Baldwin Boxall BT8EX BT8 8 Zone Dial-up Interface - 110V Baldwin Boxall BT8EX BT8 8 Zone Dial-up Interface - 110VMake publicstaff announcements through your telephone systemInstalling a BT8 enables staff to make public address announcements from their own desk telephone by simply dialling into an allocated extension number.The free-standing units act as an interface between the analogue telephone system and the public address system.Key FeaturesAdditional facility enables the user to pre-record an announcement. This reduces the risk of feedback where the telephone is adjacent to a loudspeakerWhen connected to a telephone system with MF signalling the BT8 enables the user to select up to eight zones via the telephone keypadAn internal selector determines if the recorded message is played once or twice110V GBP 1144.88 1