60 results (0,14190 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Baldwin Boxall Omnicare Combined Red Fire Telephone and Green DRS Unit BVOCCGCP

Baldwin Boxall Omnicare Combined Red Locking Door CW Beacon BVOCCLB

Baldwin Boxall Omnicare Type B Advance Green Disable Refuge Remote BVOCA2G

Baldwin Boxall Omnicare Type B Advance Stainless Steel Disabled Refuge Remote BVOCA2S

Baldwin Boxall Omnicare Emergency Tel Green Lock Door CW Beacon BVOCETLB

Baldwin Boxall BVOCECP OmniCare Remote - Red

Baldwin Boxall Omnicare Emergency Tel Green Push Door CW Beacon BVOCETB

Baldwin Boxall DTASCBRP Care2 Call Button amp Reset Point Stainless Steel

Baldwin Boxall Omnicare Fire Tel Red Push Door CW Beacon BVOCFB

Baldwin Boxall CARE2 EVC Control Panel 4-way C2CB4

Baldwin Boxall CARE2 EVC Control Panel 4-way C2CB4

Baldwin Boxall CARE2 EVC Control Panel 4-way C2CB4Care2 is a radial wired emergency voice communication system built to the high standard you expect from Baldwin Boxall. It is stylish versatile and easy to use and offers an alternative to our well-established loop-wired Omnicare range.Key FeaturesCARE2 is an all-in-one Emergency Voice Communication EVC system.Fully monitored and battery-backed 24 hours quiescent and three hours functional.Fully compliant to BS5839-92011. Assists companies with compliance to BS99992008.Remote units are wired in a radial star configuration using two core fire resisting enhancednon-enhanced cable.Fully networkable. Networked panels are wired in a loop configuration using 2 x two core fire resisting enhanced cable.In the event of a break in the network loop the system will continue to function.All outstations are powered from the line including the roaming telephone enclosure and disabled toilet alarms.Optional link to fire detection system prevents hoax disabled refuge calls C2CFPE required. Firefighter roaming telephones and toilet alarms remain active.Speech steered disabled refuge outstations.Full duplex speech firefighter and emergencysteward telephones.Any combination of the following outstations can be installed on a single system Disabled refuge Type B outstations Fire telephones Type A outstations Steward emergency telephones Type A outstations Roaming telephones Disabled toilet alarms.BenefitsStylish versatile and simple to navigate and control.Suitable for small or large systems - fully networkable.Monitored roaming telephone handsets - enables use with confidence.System configuration via SD card front panel or PC connection.Facilitates clear communication during an emergency event.Ideal for retro-fitting old star-wired systems.Quality built robust system.Activityfault log.Outstations including toilet alarms powered directly from the line - no local power needed.Any combination of outstation on one system.

GBP 1539.52
1

Baldwin Boxall CARE2 EVC Control Panel 4-way Stainless Steel C2CS4

Baldwin Boxall CARE2 EVC Control Panel 4-way Stainless Steel C2CS4

Baldwin Boxall CARE2 EVC Control Panel 4-way Stainless Steel C2CS4Care2 is a radial wired emergency voice communication system built to the high standard you expect from Baldwin Boxall. It is stylish versatile and easy to use and offers an alternative to our well-established loop-wired Omnicare range.Key FeaturesCARE2 is an all-in-one Emergency Voice Communication EVC system.Fully monitored and battery-backed 24 hours quiescent and three hours functional.Fully compliant to BS5839-92011. Assists companies with compliance to BS99992008.Remote units are wired in a radial star configuration using two core fire resisting enhancednon-enhanced cable.Fully networkable. Networked panels are wired in a loop configuration using 2 x two core fire resisting enhanced cable.In the event of a break in the network loop the system will continue to function.All outstations are powered from the line including the roaming telephone enclosure and disabled toilet alarms.Optional link to fire detection system prevents hoax disabled refuge calls C2CFPE required. Firefighter roaming telephones and toilet alarms remain active.Speech steered disabled refuge outstations.Full duplex speech firefighter and emergencysteward telephones.Any combination of the following outstations can be installed on a single system Disabled refuge Type B outstations Fire telephones Type A outstations Steward emergency telephones Type A outstations Roaming telephones Disabled toilet alarms.BenefitsStylish versatile and simple to navigate and control.Suitable for small or large systems - fully networkable.Monitored roaming telephone handsets - enables use with confidence.System configuration via SD card front panel or PC connection.Facilitates clear communication during an emergency event.Ideal for retro-fitting old star-wired systems.Quality built robust system.Activityfault log.Outstations including toilet alarms powered directly from the line - no local power needed.Any combination of outstation on one system.

GBP 1771.76
1

Baldwin Boxall Omnicare Type A Red Fire Telephone with Push Door BVOCF

Baldwin Boxall Omnicare Type A Red Fire Telephone with Push Door BVOCF

Baldwin Boxall Omnicare Type A Red Fire Telephone with Push Door BVOCFThe OmniCare system offers a choice of outstation units which can be wired on the same loop from the control panel. The BVOCF red fire telephone unit is one of the options available on this versatile system.Fire telephones are used by fire officers and those responsible for the evacuation of a building during an emergency. They provide essential communication for those in control. When operated by opening the door of the enclosure the persons managing the evacuation at the control panel can immediately see the location of the caller as this is indicated on the panel. The fire officer at the telephone point can relay the situation and confirm if that area is clear of personnelpublic before moving to the next levelarea.The fire telephone is connected to the control panel in a loop circuit and can be included with disabled refuge outstations on the same panel.Key FeaturesProvides two-way full duplex speech communication.Self-powered from ring circuit no local power source is required. Automatic battery backup is provided by the control panel in the event of a mains power failure.Red finish also available in stainless steel BVOCFS.Push catch door slot lock version available BVOCFL.Addressable unit.The enclosure contains a rugged red handset with hearing aid compatible earpiece and loudspeaker.Calls are initiated upon opening the door. When answered the user can talk to the operator either by lifting the handset or hands-free. Closing the door ends the call.Conference call facility between multiple fire telephones is available via the operator at the control panel.All outstations are in a loop circuit from control panels.Surface mountable or flush mount with optional bezel.

GBP 540.70
1

Baldwin Boxall Omnicare Combined Stainless Steel Disabled Refuge Unit with Lock Door BVOCCSL

Baldwin Boxall Omnicare Combined Stainless Steel Disabled Refuge Unit with Lock Door BVOCCSL

Baldwin Boxall Omnicare Combined Stainless Steel Disabled Refuge Unit with Lock Door BVOCCSLThe combined unit for the Omnicare Loop-wired EVC system provides two types of call point at one location. This unit was the first of its kind on the market and has been installed in many locations worldwide.The Omnicare combined outstation has been specially designed so that it can be installed in such a way as to enable correct mounting heights for each section of the unit as laid out in BS5839-9. The combined unit can be placed on the wiring loop in combination with any other Omnicare style outstation providing users great flexibility and choice.Key FeaturesSelf-powered from ring circuit no local power source is required. Automatic battery backup is provided by the control panel in the event of a mains power failure.Stainless steel finish also available in red BVOCC.Slot lock door.Addressable unit.Surface mount or flush mount with optional bezel.All outstations are in a loop circuit from control panels.Fire telephone Provides two-way full duplex speech communication.The fire telephone section contains a rugged red handset with hearing aid compatible earpiece and loudspeaker.Calls are initiated upon opening the door. When answered the user can talk to the operator either by lifting the handset or hands-free. Closing the door ends the call.Conference call facility between multiple fire telephones is available via the operator at the control panel.Disabled refuge remote Provides two-way hands free speech steered communication.Volt free contact active when occupied. To operate over-door lamps silence speakersounder etc.Stainless steel press to call button.Calls can be reset either by of the key-switch on the remote unit or at the master control panel.Option to be permanently active if required.Reset from either remote unit using the key switch or via the master control panel.Please note Stainless steel products are not intended for installation in humid areas.

GBP 1071.41
1

Baldwin Boxall Omnicare Type A Red Fire Telephone with Lock Door BVOCFL

Baldwin Boxall Omnicare Type A Red Fire Telephone with Lock Door BVOCFL

Baldwin Boxall Omnicare Type A Red Fire Telephone with Lock Door BVOCFLThe OmniCare system offers a choice of outstation units which can be wired on the same loop from the control panel. The BVOCFL red fire telephone unit is one of the options available on this versatile system.Fire telephones are used by fire officers and those responsible for the evacuation of a building during an emergency. They provide essential communication for those in control. When operated by opening the door of the enclosure the persons managing the evacuation at the control panel can immediately see the location of the caller as this is indicated on the panel. The fire officer at the telephone point can relay the situation and confirm if that area is clear of personnelpublic before moving to the next levelarea.The fire telephone is connected to the control panel in a loop circuit and can be included with disabled refuge outstations on the same panel if these are required. As an option the Omnicare system also has a combined outstation which includes both a fire telephone and a disabled refuge unit in the same enclosure.Key FeaturesProvides two-way full duplex speech communication.Self-powered from ring circuit no local power source is required. Automatic battery backup is provided by the control panel in the event of a mains power failure.Red finish also available in stainless steel BVOCFSL.Slot lock door push catch version available BVOCF.Addressable unit.The enclosure contains a rugged red handset with hearing aid compatible earpiece and loudspeaker.Calls are initiated upon opening the door. When answered the user can talk to the operator either by lifting the handset or hands-free. Closing the door ends the call.Conference call facility between multiple fire telephones is available via the operator at the control panel.All outstations are in a loop circuit from control panels.Surface mountable or flush mount with optional bezel.

GBP 576.98
1

Baldwin Boxall Omnicare Combined Disabled Refuge Unit with Lock Door BVOCCL

Baldwin Boxall Omnicare Combined Disabled Refuge Unit with Lock Door BVOCCL

Baldwin Boxall Omnicare Combined Disabled Refuge Unit with Lock Door BVOCCLThe combined unit for the Omnicare LOOP-wired EVC system provides two types of call point at one location. This unit was the first of its kind on the market and has been installed in many locations worldwide.The Omnicare combined outstation has been specially designed so that it can be installed in such a way as to enable correct mounting heights for each section of the unit as laid out in BS5839-9. The combined unit can be placed on the wiring loop in combination with any other Omnicare style outstation providing users great flexibility and choice.Key FeaturesSelf-powered from ring circuit no local power source is required. Automatic battery backup is provided by the control panel in the event of a mains power failure.Red finish also available in stainless steel BVOCCS.Slot lock door.Addressable unit.Surface mount or flush mount with optional bezel.All outstations are in a loop circuit from control panels.Fire telephone Features Provides two-way full duplex speech communication.The fire telephone section contains a rugged red handset with hearing aid compatible earpiece and loudspeaker.Calls are initiated upon opening the door. When answered the user can talk to the operator either by lifting the handset or hands-free. Closing the door ends the call.Conference call facility between multiple fire telephones is available via the operator at the control panel.Disabled refuge remote Provides two-way hands free speech steered communication.Volt free contact active when occupied. To operate over-door lamps silence speakersounder etc.Stainless steel press to call button.Calls can be reset either by of the key-switch on the remote unit or at the master control panel.Option to be permanently active if required.Reset from either remote unit using the key switch or via the master control panel.

GBP 886.33
1

Baldwin Boxall Omnicare Combined Stainless Steel Disabled Refuge Unit with Push Door BVOCCSP

Baldwin Boxall Omnicare Combined Stainless Steel Disabled Refuge Unit with Push Door BVOCCSP

Baldwin Boxall Omnicare Combined Stainless Steel Disabled Refuge Unit with Push Door BVOCCSPThe combined unit for the Omnicare Loop-wired EVC system provides two types of call point at one location. This unit was the first of its kind on the market and has been installed in many locations worldwide.The Omnicare combined outstation has been specially designed so that it can be installed in such a way as to enable correct mounting heights for each section of the unit as laid out in BS5839-9. The combined unit can be placed on the wiring loop in combination with any other Omnicare style outstation providing users great flexibility and choice.Key FeaturesSelf-powered from ring circuit no local power source is required. Automatic battery backup is provided by the control panel in the event of a mains power failure.Stainless steel finish also available in red BVOCC.Push catch door.Addressable unit.Surface mount or flush mount with optional bezel.All outstations are in a loop circuit from control panels.Fire telephone Provides two-way full duplex speech communication.The fire telephone section contains a rugged red handset with hearing aid compatible earpiece and loudspeaker.Calls are initiated upon opening the door. When answered the user can talk to the operator either by lifting the handset or hands-free. Closing the door ends the call.Conference call facility between multiple fire telephones is available via the operator at the control panel.Disabled refuge remote Provides two-way hands free speech steered communication.Volt free contact active when occupied. To operate over-door lamps silence speakersounder etc.Stainless steel press to call button.Calls can be reset either by of the key-switch on the remote unit or at the master control panel.Option to be permanently active if required.Reset from either remote unit using the key switch or via the master control panel.Please note Stainless steel products are not intended for installation in humid areas.

GBP 1041.47
1

Baldwin Boxall Omnicare Combined Disabled Refuge Unit with Push Door BVOCC

Baldwin Boxall Omnicare Combined Disabled Refuge Unit with Push Door BVOCC

Baldwin Boxall Omnicare Combined Disabled Refuge Unit with Push Door BVOCCThe combined unit for the Omnicare Loop-wired EVC system provides two types of call point at one location. This unit was the first of its kind on the market and has been installed in many locations worldwide.The Omnicare combined outstation has been specially designed so that it can be installed in such a way as to enable correct mounting heights for each section of the unit as laid out in BS5839-9. The combined unit can be placed on the wiring loop in combination with any other Omnicare style outstation providing users great flexibility and choice.Key FeaturesSelf-powered from ring circuit no local power source is required. Automatic battery backup is provided by the control panel in the event of a mains power failure.Red finish also available in stainless steel BVOCCS.Push catch door.Addressable unit.Surface mount or flush mount with optional bezel.All outstations are in a loop circuit from control panels.Fire telephone Features Provides two-way full duplex speech communication.The fire telephone section contains a rugged red handset with hearing aid compatible earpiece and loudspeaker.Calls are initiated upon opening the door. When answered the user can talk to the operator either by lifting the handset or hands-free. Closing the door ends the call.Conference call facility between multiple fire telephones is available via the operator at the control panel.Disabled refuge remote Provides two-way hands free speech steered communication.Volt free contact active when occupied. To operate over-door lamps silence speakersounder etc.Stainless steel press to call button.Calls can be reset either by of the key-switch on the remote unit or at the master control panel.Option to be permanently active if required.Reset from either remote unit using the key switch or via the master control panel.

GBP 876.36
1

Baldwin Boxall Omnicare Type B Green Disabled Refuge Remote BVOCECPG

Baldwin Boxall Omnicare Comb Red PDoor CW Beacon BVOCCB

Baldwin Boxall Omnicare Type B Stainless Steel Disabled Refuge Remote BVOCECPS

Baldwin Boxall Omnicare Type A Stainless Steel Fire Telephone with Push Door BVOCFS

Baldwin Boxall Omnicare Type A Stainless Steel Fire Telephone with Push Door BVOCFS

Baldwin Boxall Omnicare Type A Stainless Steel Fire Telephone with Push Door BVOCFSThe OmniCare system offers a choice of outstation units which can be wired on the same loop from the control panel. The BVOCFS fire telephone unit with stainless steel finish is one of the options available on this versatile system.Fire telephones are used by fire officers and those responsible for the evacuation of a building during an emergency. They provide essential communication for those in control. When operated by opening the door of the enclosure the persons managing the evacuation at the control panel can immediately see the location of the caller as this is indicated on the panel. The fire officer at the telephone point can relay the situation and confirm if that area is clear of personnelpublic before moving to the next levelarea.The fire telephone is connected to the control panel in a loop circuit and can be included with disabled refuge outstations on the same panel if these are required. As an option the Omnicare system also has a combined outstation which includes both a fire telephone and a disabled refuge unit in the same enclosure.Key FeaturesProvides two-way full duplex speech communication.Self-powered from ring circuit no local power source is required. Automatic battery backup is provided by the control panel in the event of a mains power failure.Stainless steel finish also available in red BVOCF.Push catch door slot lock version available BVOCFSL.Addressable unit.The enclosure contains a rugged red handset with hearing aid compatible earpiece and loudspeaker.Calls are initiated upon opening the door. When answered the user can talk to the operator either by lifting the handset or hands-free. Closing the door ends the call.Conference call facility between multiple fire telephones is available via the operator at the control panel.All outstations are in a loop circuit from control panels.Surface mountable or flush mount with optional bezel.Please note Stainless steel products are not intended for installation in humid areas.

GBP 762.05
1

Baldwin Boxall Omnicare Type A Stainless Steel Fire Telephone with Lock Door BVOCFSL

Baldwin Boxall Omnicare Type A Stainless Steel Fire Telephone with Lock Door BVOCFSL

Baldwin Boxall Omnicare Type A Stainless Steel Fire Telephone with Lock Door BVOCFSLThe OmniCare system offers a choice of outstation units which can be wired on the same loop from the control panel. The BVOCFSL fire telephone unit with stainless steel finish is one of the options available on this versatile system.Fire telephones are used by fire officers and those responsible for the evacuation of a building during an emergency. They provide essential communication for those in control. When operated by opening the door of the enclosure the persons managing the evacuation at the control panel can immediately see the location of the caller as this is indicated on the panel. The fire officer at the telephone point can relay the situation and confirm if that area is clear of personnelpublic before moving to the next levelarea.The fire telephone is connected to the control panel in a loop circuit and can be included with disabled refuge outstations on the same panel if these are required. As an option the Omnicare system also has a combined outstation which includes both a fire telephone and a disabled refuge unit in the same enclosure.Key FeaturesProvides two-way full duplex speech communication.Self-powered from ring circuit no local power source is required. Automatic battery backup is provided by the control panel in the event of a mains power failure.Stainless steel finish also available in red BVOCFL.Slot lock door push catch version available BVOCFS.Addressable unit.The enclosure contains a rugged red handset with hearing aid compatible earpiece and loudspeaker.Calls are initiated upon opening the door. When answered the user can talk to the operator either by lifting the handset or hands-free. Closing the door ends the call.Conference call facility between multiple fire telephones is available via the operator at the control panel.All outstations are in a loop circuit from control panels.Surface mountable or flush mount with optional bezel.Please note Stainless steel products are not intended for installation in humid areas.

GBP 799.25
1