Baldwin Boxall ROPBP1 Rack Option Panel Single Blank Panel Baldwin Boxall ROPBP1 Rack Option Panel Single Blank PanelThe ROPBP1 manufactured by Baldwin Boxall is aRack Option Panel single blank panel. GBP 13.61 1
Baldwin Boxall ROPIP Rack Option Panel Input Baldwin Boxall ROPIP Rack Option Panel InputThe ROPIP manufactured by Baldwin Boxall is aRack Option Panel designed for input applications. GBP 38.10 1
Baldwin Boxall BVRDCIMON CI Fire Panel Monitor Module Baldwin Boxall BVRDCIMON CI Fire Panel Monitor ModuleThe BVRDCIMON is a CI Fire Panel Monitor Module.Baldwin Boxall is a quality manufacturer of voice alarm VA and emergency voice communication EVC systems which aid in life safety. GBP 44.45 1
Baldwin Boxall CARE2 Fire Panel Ethernet Module C2CFPE Baldwin Boxall CARE2 Fire Panel Ethernet Module C2CFPEAs supplied the Care2 system is permanently active and all DRS Refuge Remotes are able to make calls all the time. The C2CFPE Fire Panel Interface card enables the DRS Refuge Remotes to be active only when a Fire Panel is active. The Interface Card also provides the Common Fault Volt Free contacts and the Ethernet contacts. GBP 86.18 1
Baldwin Boxall Fire Panel Interface BVRDFPI Baldwin Boxall Fire Panel Interface BVRDFPIVIGIL EVAS voice evacuation systems provide the solution for many projects regardless of size layout or type. The BVRDFPI canbus module is a fire panel interface.Key Features 24 x opto-coupled inputs from fire detection system.1 x common fault volt-free changeover relay contacts.1 x RS485 half-duplex port for communicating to control microphones fire detection systems network control fault reporting. GBP 471.74 1
Baldwin Boxall Single Gang Room Panel for Local Audio Control RPVS Baldwin Boxall Single Gang Room Panel for Local Audio Control RPVSA room panel enables local control of audio facilities useful for hotelconference rooms and many other applications. There are two versions of the VIGIL room panel adding more options to our EVAS voice alarm and public address systems.Key FeaturesConnection to the main EVAS control rack is via CAT5.Optional robust cover available.Brushed stainless steel finish.Provides control of local audio settings volume music source etc.Emergency broadcasts from the EVAS voice alarm system will override the room panel settings.Controls broadcast volume for local area.Six position channel select control.USB socket on the rear of the panel for initial configuration.Protective cover available RPP1. GBP 247.67 1
Baldwin Boxall Double Gang Room Panel for Local Audio Control RPAIV Baldwin Boxall Double Gang Room Panel for Local Audio Control RPAIVA room panel enables local control of audio facilities useful for hotelconference rooms and many other applications. There are two versions of the VIGIL room panel adding more options to our EVAS voice alarm and public address systems.Key FeaturesConnection to the main EVAS control rack is via CAT5.Optional robust cover available.Brushed stainless steel finish.Provides control of local audio settings volume music source etc.Emergency broadcasts from the EVAS voice alarm system will override the room panel settings.Enables connection of music source andor mic for local broadcast.Microphone connector is a 3-pin XLR6.35 mm jack socket.Two phono sockets and 3.5 mm jack socket.Highlow sensitivity switch for microphone.Protective cover available RPP2. GBP 289.39 1
Baldwin Boxall ROPVC Rack Option Panel Single Volume Control Baldwin Boxall ROPVC Rack Option Panel Single VolumeControlThe ROPVC manufactured by Baldwin Boxall is a rack optionpanel designed with single volume control. GBP 53.52 1
Baldwin Boxall ROPSWFT Rack Option Panel X2 Fliptop Switches Baldwin Boxall ROPSWFT Rack Option Panel X2 FliptopSwitchesThe ROPVC manufactured by Baldwin Boxall is a rack option paneldesigned with two fliptop switches. GBP 156.95 1
Baldwin Boxall BV3FPI Vigil 3 Fire Panel Interface Baldwin Boxall BV3FPI Vigil 3 Fire Panel InterfaceThe BV3FPI is a Vigil 3 Fire Panel Interface which is compatible with the Vigil 3 Audio Output Module.Built on decades of experience Baldwin Boxalls Vigil 3 is their most flexible scalable and powerful system to date. It is their next generation of voice alarm and as with all of Baldwin Boxalls products the range has been designed and built with quality and absolute reliability in mind. GBP 249.48 1
Baldwin Boxall ROPSWKEY Rack Option Panel X2 Key Switch Baldwin Boxall ROPSWKEY Rack Option Panel X2 Key SwitchThe ROPVC manufactured by Baldwin Boxall is a rack option paneldesigned with two key switches. GBP 51.71 1
Baldwin Boxall ROPSW Rack Option Panel Dual Paddle Switch Baldwin Boxall ROPSW Rack Option Panel Dual Paddle SwitchThe ROPSW manufactured by Baldwin Boxall is a rack option paneldesigned with a dual paddle switch. GBP 97.07 1
Baldwin Boxall ROPJ3 Rack Option Panel 3.5mm Jack Socket Baldwin Boxall ROPJ3 Rack Option Panel 3.5mm Jack SocketThe ROPSW manufactured by Baldwin Boxall is a rack option paneldesigned with a 3.5mm jack socket. GBP 39.01 1
Baldwin Boxall ROPMF Rack Option Panel Mainframe x10 Per ROPMF Baldwin Boxall ROPMF Rack Option Panel Mainframe x10 PerROPMFThe ROPSW manufactured by Baldwin Boxall is a rack option panelmainframe x10 per ROPMF GBP 71.66 1
Baldwin Boxall Care2 EVC Network Expansion Panel C2CSNEP Baldwin Boxall Care2 EVC Network Expansion Panel C2CSNEPThe Network Expansion Panel NEP adds to the flexibility of the Care2 EVC system. Whether you require one outstation or 256 outstations Care2 can meet your needs.Each 4-way panel can be expanded to 8 12 or 16-way by means of an optional expansion kit not factory fitted.Key FeaturesUp to 15 NEPs can be fitted on one system 14 if installing two control panelsEach NEP is supplied with a 4-way line card add up to 3 expansion kits to enable 8 12 or 16-waySystems with up to 256 outstations possible larger systems can be installed please contact our sales departmentFor initial system set up and local testing prior to connection to the network a roaming telephone can be temporarily connected to an internal socketAt each NEP the status of local outstations can be viewed by using the rotary encoder and LCD screenBlack or stainless steelSurface mount optional flush mount bezel available GBP 2255.30 1
Baldwin Boxall CARE2 Network Expansion Panel 4-way C2CBNEP Baldwin Boxall CARE2 Network Expansion Panel 4-way C2CBNEPThe Network Expansion Panel NEP adds to the flexibility of the Care2 EVC system. Whether you require one outstation or 256 outstations Care2 can meet your needs. Each 4-way panel can be expanded to 8 12 or 16-way by means of an optional expansion kit not factory fitted.Key FeaturesUp to 15 NEPs can be fitted on one system 14 if installing two control panelsEach NEP is supplied with a 4-way line card add up to 3 expansion kits to enable 8 12 or 16-waySystems with up to 256 outstations possible larger systems can be installed please contact our sales departmentFor initial system set up and local testing prior to connection to the network a roaming telephone can be temporarily connected to an internal socketAt each NEP the status of local outstations can be viewed by using the rotary encoder and LCD screenSurface mount optional flush mount bezel available GBP 2096.54 1
Baldwin Boxall Omnicare Large EVC Control Panel 128-way BVOC128 Baldwin Boxall Omnicare Large EVC Control Panel 128-way BVOC128Omnicare is a loop wired addressable emergency voice communication system that allows disabled refuge fire telephones steward telephones and disabled toilet alarms to be connected to one panel. Omnicare can be easily networked with the ability to add multiple control panels on a system. This enables local zonearea control with gatehousemanagement control on a master panel.The control panel features an output for an external call indicator. This is designed for use in situations where the control panel is mounted in an unmanned area. Using this output a remote indicator can be fitted in a location where it is visibleheard such as in a reception area. The output has a programmable delay feature so that calls answered at the panel are not relayed to the remote lampbuzzer indicator.Panel options include sizes from four-way up to 128-way and are supplied with the relevant batteries for backup should the mains power fail. Four-way up to 128-way versions of the control panel available in either grey or stainless-steel finish. Omnicare has been designed and built to meet BS99992008 BS5839-92011 and BS83002009 for the disabled toilet alarm.Key FeaturesDigital audio full duplex or speech steered remote dependent.One master and multiple slaves can be networked on one system panels are configured on installation.Surface mountable or optional flush mounting with bezel.Dedicated button control for each outstation with status LED indicators.Lockable glazed door.Remote units are connected to the master control panel in a loop configuration using fire rated enhanced four-core cable. OmniCare cabling networking.Fully monitored and battery backed separate box to house batteries supplied with panels larger than 32-way.The system is addressable via the remote units.System BenefitsMultiple masterslave panels can be linked in one system.Full system monitoring.Choice of outstations including disabled toilet alarms addressable via the remote unit.Link to fire detection system prevents hoax disabled refuge calls toilet alarms and fire telephones remain active. Can be completely or partly overridden.Speech steered disabled refuge remotes and full duplex speech fire telephones and emergency telephones.Battery backed for use in the event of mains power failure 24 hours in standby plus three hours use as standard. These times can be increased if required. Please contact our Sales Department for advice.Wired in a loop configuration. GBP 6592.62 1
Baldwin Boxall Omnicare Large EVC Control Panel 96-way BVOC96 Baldwin Boxall Omnicare Large EVC Control Panel 96-way BVOC96Omnicare is a loop wired addressable emergency voice communication system that allows disabled refuge fire telephones steward telephones and disabled toilet alarms to be connected to one panel. Omnicare can be easily networked with the ability to add multiple control panels on a system. This enables local zonearea control with gatehousemanagement control on a master panel.The control panel features an output for an external call indicator. This is designed for use in situations where the control panel is mounted in an unmanned area. Using this output a remote indicator can be fitted in a location where it is visibleheard such as in a reception area. The output has a programmable delay feature so that calls answered at the panel are not relayed to the remote lampbuzzer indicator.Panel options include sizes from four-way up to 128-way and are supplied with the relevant batteries for backup should the mains power fail. Four-way up to 128-way versions of the control panel available in either grey or stainless-steel finish. Omnicare has been designed and built to meet BS99992008 BS5839-92011 and BS83002009 for the disabled toilet alarm.Key FeaturesDigital audio full duplex or speech steered remote dependent.One master and multiple slaves can be networked on one system panels are configured on installation.Surface mountable or optional flush mounting with bezel.Dedicated button control for each outstation with status LED indicators.Lockable glazed door.Remote units are connected to the master control panel in a loop configuration using fire rated enhanced four-core cable. OmniCare cabling networking.Fully monitored and battery backed separate box to house batteries supplied with panels larger than 32-way.The system is addressable via the remote units.System BenefitsMultiple masterslave panels can be linked in one system.Full system monitoring.Choice of outstations including disabled toilet alarms addressable via the remote unit.Link to fire detection system prevents hoax disabled refuge calls toilet alarms and fire telephones remain active. Can be completely or partly overridden.Speech steered disabled refuge remotes and full duplex speech fire telephones and emergency telephones.Battery backed for use in the event of mains power failure 24 hours in standby plus three hours use as standard. These times can be increased if required. Please contact our Sales Department for advice.Wired in a loop configuration. GBP 5951.23 1
Baldwin Boxall Omnicare Standard EVC Control Panel 64-way BVOC64 Baldwin Boxall Omnicare Standard EVC Control Panel 64-way BVOC64Omnicare is a loop wired addressable emergency voice communication system that allows disabled refuge fire telephones steward telephones and disabled toilet alarms to be connected to one panel. Omnicare can be easily networked with the ability to add multiple control panels on a system. This enables local zonearea control with gatehousemanagement control on a master panel.The control panel features an output for an external call indicator. This is designed for use in situations where the control panel is mounted in an unmanned area. Using this output a remote indicator can be fitted in a location where it is visibleheard such as in a reception area. The output has a programmable delay feature so that calls answered at the panel are not relayed to the remote lampbuzzer indicator.Panel options include sizes from four-way up to 128-way and are supplied with the relevant batteries for backup should the mains power fail. Four-way up to 128-way versions of the control panel available in either grey or stainless-steel finish. Omnicare has been designed and built to meet BS99992008 BS5839-92011 and BS83002009 for the disabled toilet alarm.Key FeaturesDigital audio full duplex or speech steered remote dependent.One master and multiple slaves can be networked on one system panels are configured on installation.Surface mountable or optional flush mounting with bezel.Dedicated button control for each outstation with status LED indicators.Lockable glazed door.Remote units are connected to the master control panel in a loop configuration using fire rated enhanced four-core cable. OmniCare cabling networking.Fully monitored and battery backed separate box to house batteries supplied with panels larger than 32-way.The system is addressable via the remote units.System BenefitsMultiple masterslave panels can be linked in one system.Full system monitoring.Choice of outstations including disabled toilet alarms addressable via the remote unit.Link to fire detection system prevents hoax disabled refuge calls toilet alarms and fire telephones remain active. Can be completely or partly overridden.Speech steered disabled refuge remotes and full duplex speech fire telephones and emergency telephones.Battery backed for use in the event of mains power failure 24 hours in standby plus three hours use as standard. These times can be increased if required. Please contact our Sales Department for advice.Wired in a loop configuration. GBP 4292.87 1
Baldwin Boxall Omnicare Mini EVC Control Panel 16-way BVOC16M Baldwin Boxall Omnicare Mini EVC Control Panel 16-way BVOC16MOmnicare is a loop wired addressable emergency voice communication system that allows disabled refuge fire telephones steward telephones and disabled toilet alarms to be connected to one panel. Omnicare can be easily networked with the ability to add multiple control panels on a system. This enables local zonearea control with gatehousemanagement control on a master panel.The control panel features an output for an external call indicator. This is designed for use in situations where the control panel is mounted in an unmanned area. Using this output a remote indicator can be fitted in a location where it is visibleheard such as in a reception area. The output has a programmable delay feature so that calls answered at the panel are not relayed to the remote lampbuzzer indicator.Panel options include sizes from four-way up to 128-way and are supplied with the relevant batteries for backup should the mains power fail. Four-way up to 128-way versions of the control panel available in either grey or stainless-steel finish. Omnicare has been designed and built to meet BS99992008 BS5839-92011 and BS83002009 for the disabled toilet alarm.Key FeaturesDigital audio full duplex or speech steered remote dependent.One master and multiple slaves can be networked on one system panels are configured on installation.Surface mountable or optional flush mounting with bezel.Dedicated button control for each outstation with status LED indicators.Lockable glazed door.Remote units are connected to the master control panel in a loop configuration using fire rated enhanced four-core cable. OmniCare cabling networking.Fully monitored and battery backed separate box to house batteries supplied with panels larger than 32-way.The system is addressable via the remote units.System BenefitsMultiple masterslave panels can be linked in one system.Full system monitoring.Choice of outstations including disabled toilet alarms addressable via the remote unit.Link to fire detection system prevents hoax disabled refuge calls toilet alarms and fire telephones remain active. Can be completely or partly overridden.Speech steered disabled refuge remotes and full duplex speech fire telephones and emergency telephones.Battery backed for use in the event of mains power failure 24 hours in standby plus three hours use as standard. These times can be increased if required. Please contact our Sales Department for advice.Wired in a loop configuration. GBP 1843.43 1
Baldwin Boxall Omnicare Mini EVC Control Panel 4-way BVOC4M Baldwin Boxall Omnicare Mini EVC Control Panel 4-way BVOC4MOmnicare is a loop wired addressable emergency voice communication system that allows disabled refuge fire telephones steward telephones and disabled toilet alarms to be connected to one panel. Omnicare can be easily networked with the ability to add multiple control panels on a system. This enables local zonearea control with gatehousemanagement control on a master panel.The control panel features an output for an external call indicator. This is designed for use in situations where the control panel is mounted in an unmanned area. Using this output a remote indicator can be fitted in a location where it is visibleheard such as in a reception area. The output has a programmable delay feature so that calls answered at the panel are not relayed to the remote lampbuzzer indicator.Panel options include sizes from four-way up to 128-way and are supplied with the relevant batteries for backup should the mains power fail. Four-way up to 128-way versions of the control panel available in either grey or stainless-steel finish. Omnicare has been designed and built to meet BS99992008 BS5839-92011 and BS83002009 for the disabled toilet alarm.Key FeaturesDigital audio full duplex or speech steered remote dependent.One master and multiple slaves can be networked on one system panels are configured on installation.Surface mountable or optional flush mounting with bezel.Dedicated button control for each outstation with status LED indicators.Lockable glazed door.Remote units are connected to the master control panel in a loop configuration using fire rated enhanced four-core cable. OmniCare cabling networking.Fully monitored and battery backed separate box to house batteries supplied with panels larger than 32-way.The system is addressable via the remote units.System BenefitsMultiple masterslave panels can be linked in one system.Full system monitoring.Choice of outstations including disabled toilet alarms addressable via the remote unit.Link to fire detection system prevents hoax disabled refuge calls toilet alarms and fire telephones remain active. Can be completely or partly overridden.Speech steered disabled refuge remotes and full duplex speech fire telephones and emergency telephones.Battery backed for use in the event of mains power failure 24 hours in standby plus three hours use as standard. These times can be increased if required. Please contact our Sales Department for advice.Wired in a loop configuration. GBP 1578.53 1
Baldwin Boxall Omnicare Mini EVC Control Panel 32-way BVOC32M Baldwin Boxall Omnicare Mini EVC Control Panel 32-way BVOC32MOmnicare is a loop wired addressable emergency voice communication system that allows disabled refuge fire telephones steward telephones and disabled toilet alarms to be connected to one panel. Omnicare can be easily networked with the ability to add multiple control panels on a system. This enables local zonearea control with gatehousemanagement control on a master panel.The control panel features an output for an external call indicator. This is designed for use in situations where the control panel is mounted in an unmanned area. Using this output a remote indicator can be fitted in a location where it is visibleheard such as in a reception area. The output has a programmable delay feature so that calls answered at the panel are not relayed to the remote lampbuzzer indicator.Panel options include sizes from four-way up to 128-way and are supplied with the relevant batteries for backup should the mains power fail. Four-way up to 128-way versions of the control panel available in either grey or stainless-steel finish. Omnicare has been designed and built to meet BS99992008 BS5839-92011 and BS83002009 for the disabled toilet alarm.Key FeaturesDigital audio full duplex or speech steered remote dependent.One master and multiple slaves can be networked on one system panels are configured on installation.Surface mountable or optional flush mounting with bezel.Dedicated button control for each outstation with status LED indicators.Lockable glazed door.Remote units are connected to the master control panel in a loop configuration using fire rated enhanced four-core cable. OmniCare cabling networking.Fully monitored and battery backed separate box to house batteries supplied with panels larger than 32-way.The system is addressable via the remote units.System BenefitsMultiple masterslave panels can be linked in one system.Full system monitoring.Choice of outstations including disabled toilet alarms addressable via the remote unit.Link to fire detection system prevents hoax disabled refuge calls toilet alarms and fire telephones remain active. Can be completely or partly overridden.Speech steered disabled refuge remotes and full duplex speech fire telephones and emergency telephones.Battery backed for use in the event of mains power failure 24 hours in standby plus three hours use as standard. These times can be increased if required. Please contact our Sales Department for advice.Wired in a loop configuration. GBP 2522.93 1
Baldwin Boxall Omnicare Large EVC Control Panel 112-way BVOC112 Baldwin Boxall Omnicare Large EVC Control Panel 112-way BVOC112Omnicare is a loop wired addressable emergency voice communication system that allows disabled refuge fire telephones steward telephones and disabled toilet alarms to be connected to one panel. Omnicare can be easily networked with the ability to add multiple control panels on a system. This enables local zonearea control with gatehousemanagement control on a master panel.The control panel features an output for an external call indicator. This is designed for use in situations where the control panel is mounted in an unmanned area. Using this output a remote indicator can be fitted in a location where it is visibleheard such as in a reception area. The output has a programmable delay feature so that calls answered at the panel are not relayed to the remote lampbuzzer indicator.Panel options include sizes from four-way up to 128-way and are supplied with the relevant batteries for backup should the mains power fail. Four-way up to 128-way versions of the control panel available in either grey or stainless-steel finish. Omnicare has been designed and built to meet BS99992008 BS5839-92011 and BS83002009 for the disabled toilet alarm.Key FeaturesDigital audio full duplex or speech steered remote dependent.One master and multiple slaves can be networked on one system panels are configured on installation.Surface mountable or optional flush mounting with bezel.Dedicated button control for each outstation with status LED indicators.Lockable glazed door.Remote units are connected to the master control panel in a loop configuration using fire rated enhanced four-core cable. OmniCare cabling networking.Fully monitored and battery backed separate box to house batteries supplied with panels larger than 32-way.The system is addressable via the remote units.System BenefitsMultiple masterslave panels can be linked in one system.Full system monitoring.Choice of outstations including disabled toilet alarms addressable via the remote unit.Link to fire detection system prevents hoax disabled refuge calls toilet alarms and fire telephones remain active. Can be completely or partly overridden.Speech steered disabled refuge remotes and full duplex speech fire telephones and emergency telephones.Battery backed for use in the event of mains power failure 24 hours in standby plus three hours use as standard. These times can be increased if required. Please contact our Sales Department for advice.Wired in a loop configuration. GBP 6382.15 1
Baldwin Boxall Omnicare Large EVC Control Panel 80-way BVOC80 Baldwin Boxall Omnicare Large EVC Control Panel 80-way BVOC80Omnicare is a loop wired addressable emergency voice communication system that allows disabled refuge fire telephones steward telephones and disabled toilet alarms to be connected to one panel. Omnicare can be easily networked with the ability to add multiple control panels on a system. This enables local zonearea control with gatehousemanagement control on a master panel.The control panel features an output for an external call indicator. This is designed for use in situations where the control panel is mounted in an unmanned area. Using this output a remote indicator can be fitted in a location where it is visibleheard such as in a reception area. The output has a programmable delay feature so that calls answered at the panel are not relayed to the remote lampbuzzer indicator.Panel options include sizes from four-way up to 128-way and are supplied with the relevant batteries for backup should the mains power fail. Four-way up to 128-way versions of the control panel available in either grey or stainless-steel finish. Omnicare has been designed and built to meet BS99992008 BS5839-92011 and BS83002009 for the disabled toilet alarm.Key FeaturesDigital audio full duplex or speech steered remote dependent.One master and multiple slaves can be networked on one system panels are configured on installation.Surface mountable or optional flush mounting with bezel.Dedicated button control for each outstation with status LED indicators.Lockable glazed door.Remote units are connected to the master control panel in a loop configuration using fire rated enhanced four-core cable. OmniCare cabling networking.Fully monitored and battery backed separate box to house batteries supplied with panels larger than 32-way.The system is addressable via the remote units.System BenefitsMultiple masterslave panels can be linked in one system.Full system monitoring.Choice of outstations including disabled toilet alarms addressable via the remote unit.Link to fire detection system prevents hoax disabled refuge calls toilet alarms and fire telephones remain active. Can be completely or partly overridden.Speech steered disabled refuge remotes and full duplex speech fire telephones and emergency telephones.Battery backed for use in the event of mains power failure 24 hours in standby plus three hours use as standard. These times can be increased if required. Please contact our Sales Department for advice.Wired in a loop configuration. GBP 5857.79 1
Baldwin Boxall Omnicare Mini EVC Control Panel 8-way BVOC8M Baldwin Boxall Omnicare Mini EVC Control Panel 8-way BVOC8MOmnicare is a loop wired addressable emergency voice communication system that allows disabled refuge fire telephones steward telephones and disabled toilet alarms to be connected to one panel. Omnicare can be easily networked with the ability to add multiple control panels on a system. This enables local zonearea control with gatehousemanagement control on a master panel.The control panel features an output for an external call indicator. This is designed for use in situations where the control panel is mounted in an unmanned area. Using this output a remote indicator can be fitted in a location where it is visibleheard such as in a reception area. The output has a programmable delay feature so that calls answered at the panel are not relayed to the remote lampbuzzer indicator.Panel options include sizes from four-way up to 128-way and are supplied with the relevant batteries for backup should the mains power fail. Four-way up to 128-way versions of the control panel available in either grey or stainless-steel finish. Omnicare has been designed and built to meet BS99992008 BS5839-92011 and BS83002009 for the disabled toilet alarm.Key FeaturesDigital audio full duplex or speech steered remote dependent.One master and multiple slaves can be networked on one system panels are configured on installation.Surface mountable or optional flush mounting with bezel.Dedicated button control for each outstation with status LED indicators.Lockable glazed door.Remote units are connected to the master control panel in a loop configuration using fire rated enhanced four-core cable. OmniCare cabling networking.Fully monitored and battery backed separate box to house batteries supplied with panels larger than 32-way.The system is addressable via the remote units.System BenefitsMultiple masterslave panels can be linked in one system.Full system monitoring.Choice of outstations including disabled toilet alarms addressable via the remote unit.Link to fire detection system prevents hoax disabled refuge calls toilet alarms and fire telephones remain active. Can be completely or partly overridden.Speech steered disabled refuge remotes and full duplex speech fire telephones and emergency telephones.Battery backed for use in the event of mains power failure 24 hours in standby plus three hours use as standard. These times can be increased if required. Please contact our Sales Department for advice.Wired in a loop configuration. GBP 1729.13 1