12 results (0,14046 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Apollo Red Multi-Tone Open-Area Sounder Beacon with Isolator - 55000-293APO

Apollo Red Weatherproof Multi-Tone Open-Area Sounder Beacon with Isolator - 55000-298APO

Apollo 45681-330APO Intelligent Sounder Visual Indicator Base with Isolator

Apollo Multi-Tone Red Open-Area Sounder Visual Indicator without Isolator 55000-291APO

Apollo XP95 Sounder Beacon Base - 45681-331APO

Apollo XP95 Sounder VAD Base DIN-Tone with Isolator 45681-707APO

Apollo White Weatherproof Multi-Tone Open-Area Sounder Beacon with Isolator - 55000-299APO

Apollo White Multi-Tone Open-Area Sounder Beacon with Isolator - 55000-294APO

Apollo Discovery Sounder Base with Isolator 45681-702APO

Apollo Cat O. XP95 Sounder VAD Base with Isolator 45681-705APO

GBP 72.02
1

Apollo Weatherproof Red Multi-Tone Open-Area Sounder Visual Indicator without Isolator 55000-296APO

Apollo Weatherproof Red Multi-Tone Open-Area Sounder Visual Indicator without Isolator 55000-296APO

Please note This product is currently on an extended leadtime and will be available from June 2024. Pleasecontact usfor further information.Apollo Weatherproof Red Multi-Tone Open-Area Sounder Visual Indicator without Isolator 55000-296APOThe Weatherproof Multi-Tone Open-Area Sounder Visual Indicator is designed for use in outdoor open areas and can be connected to any Discovery or XP95 system. The sounder visual indicator complements Apollos intelligent and integrated base sounders as well as the Multi-Tone Open-Area Sounder.The Multi-tone Open-Area Alarm Devices responds to their own individual address set with a DIL switch. They can also respond to a Group Address which allows multiple sounders to be controlled simultaneously. A group address may be any spare address between 112 and 126 and is selected by means of a 4 segment DIL switch.An Alarm Device under group address control must have an individual address between 1 and 111 otherwise a fault value of 4 is transmitted. Alarm Devices not using the group address facility may be addressed at any address 1126.The Weatherproof Multi-Tone Open-Area Sounder Visual Indicator is designed for use in outdoor open areas and can be connected to any Discovery or XP95 system. The sounder visual indicator complements Apollos intelligent and integrated base sounders as well as the Multi-Tone Open-Area Sounder.Key FeaturesChoice of tones on standard device Apollo Slow Whoop and DINIP66 ratedTwo Volume settings 92dBA and 100dBASynchronisation of alert and evacuate tonesIndividual and group addressing

GBP 174.34
1

Apollo AlarmSense Open Area Sounder 55000-018APO

Apollo AlarmSense Open Area Sounder 55000-018APO

Apollo AlarmSense Open Area Sounder 55000-018APOThe AlarmSense open area sounder has an IP65 rating meaning that it is suitable for outdoor use. In the event of unauthorised sounder head removal the unit generates a fault warning but all other devices on the same zone will continue to operate.Brand InformationAlarmSense is a range of conventional fire detection and alarm products designed to be connected to the same pair of supply wires making installation quicker and less expensive.AlarmSense has been developed to make the design and installation of a fire detection and alarm system easier and more economic for small to medium-sized buildings. The range also allows an existing system to be extended or modified if necessary. This flexibility makes AlarmSense an excellent choice for use in HMOs House in Multiple Occupation.As you would expect from Apollo AlarmSense incorporates features that help reduce false alarms and patented technology to ensure the integrity of a system. The range also includes products such as beacons to help meet the requirements of the Disability Discrimination Act DDA.Brand FeaturesAlarmSense sounders and manual call points are fitted to the same zone as detectors. In quiescent state the zone is powered at between 9V and 15V nominally 12V at which only detectors and call points operate. Sounders require 24V to operate.When an alarm is detected on a zone the control panel increases the line voltage to 24V on that zone causing the sounders to produce a continuous Evacuate sound. Any voltage-sensitive output devices - relay modules or other alarm devices - also operate.When the voltage is increased to 24V the detector alarm current will reduce to 1.5mA. The detectors are latched in alarm until they are reset by reducing the voltage to less than 2V for greater than 1 second. Output devices will de-activate each time the voltage is reduced to 12V unless otherwise stated in their specification.It is possible to generate an Alert tone by pulsing the supply voltage from 12V to 24V and the sounders configured to continuous output. Pulse frequency of 1 second on 1 second off is recommended for compliance with BS5839 Pt1.Key Features Sound output of up to 99dBLPCB approvedSeparate first-fix base for ease of installationIP65 rated outdoor useDesigned for use as part of an AlarmSense fire alarm panel systemWall mountedTone synchronisationMonitors the presence of the sounder head

GBP 40.24
1