Apollo Series 65 Auxiliary Relay Base 45681-246APO Apollo Series 65 Auxiliary Relay Base - 45681-246OperationSeries 65 Relay Bases are primarily intended for use with control units using 4-wire detector supply and alarm initiating circuits. Where local codes allow they may also be used in 2 and 4-wire circuits to provide volt-free control signals to an auxiliary system such as an automatic door closer. They are not suitable for use in systems where it is specified or required that operation of the auxiliary system shall be fail-safe and must not be used with any other type of detector.Product InformationThe Series 65 Auxiliary Relay Base provides two sets of volt-free changeover contacts to facilitate the switching of a remote LED or other auxiliary device.Key FeaturesDetector locking mechanismOne way fitEasy to wireContains an earth connector GBP 18.80 1
Apollo Series 65 Standard Relay Base 45681-245APO Apollo Series 65 Standard Relay Base - 45681-245OperationSeries 65 Relay Bases are primarily intended for use with control units using 4-wire detector supply and alarm initiating circuits. Where local codes allow they may also be used in 2 and 4-wire circuits to provide volt-free control signals to an auxiliary system such as an automatic door closer. They are not suitable for use in systems where it is specified or required that operation of the auxiliary system shall be fail-safe and must not be used with any other type of detector.Product InformationThe Series 65 Standard Relay Base provides one set of volt-free changeover form C contacts that change state when the detector signals an alarm.Key FeaturesDetector locking mechanismOne-way fitEasy to wireContains an earth connector GBP 18.71 1
Apollo XP95 Mini Switch Monitor - 55000-760APO Apollo XP95 Mini Switch Monitor - 55000-760APOThe Mini Switch Monitor is an interface within an entirely new housing. Designed in response to customer feedback thesmaller Mini Switch Monitor can be fitted onto a 35mm DIN-Rail with a twist-click motion or mounted in an enclosure such as a manual call point.It is designed to monitor the state of one or more single pole volt free contacts connected to a single pair of cables and to report the status to Apollo compatible control equipment.The monitor is designed to fit into equipment with limited space or to be mounted within an enclosure such as a manual call point. The interrupt feature means the monitor can be used where a priority response is required in particular for monitoring an individual or a cone of conventional manual call points. GBP 42.22 1
Apollo Series 65 End-of-Line Relay Base 12V - 45681-247APO Apollo Series 65 End-of-Line Relay Base 12V - 45681-247OperationSeries 65 Relay Bases are primarily intended for use with control units using 4-wire detector supply and alarm initiating circuits. Where local codes allow they may also be used in 2 and 4-wire circuits to provide volt-free control signals to an auxiliary system such as an automatic door closer. They are not suitable for use in systems where it is specified or required that operation of the auxiliary system shall be fail-safe and must not be used with any other type of detector.Options45681-247 for circuits having a supply voltage between 9- and 18-volts DC and 45681-248 for circuits having a supply voltage between 16- and 33-volts DC.Product InformationThe Series 65 End-of-Line EOL Relay Base is intended for use with four-wire circuits and features two sets of changeover contacts and a power supervision relay.Key FeaturesDetector locking mechanismOne way fitEasy to wireContains an earth connector GBP 22.14 1
Apollo Series 65 End-of-Line Relay Base - 24V 45681-248APO Apollo Series 65 End-of-Line Relay Base 24V - 45681-248OperationSeries 65 Relay Bases are primarily intended for use with control units using 4-wire detector supply and alarm initiating circuits. Where local codes allow they may also be used in 2 and 4-wire circuits to provide volt-free control signals to an auxiliary system such as an automatic door closer. They are not suitable for use in systems where it is specified or required that operation of the auxiliary system shall be fail-safe and must not be used with any other type of detector.Options45681-247 for circuits having a supply voltage between 9- and 18-volts DC and 45681-248 for circuits having a supply voltage between 16 and 33 volts DC.Product InformationThe Series 65 End-of-Line EOL Relay Base is intended for use with four-wire circuits and features two sets of changeover contacts and a power supervision relay.Key FeaturesDetector locking mechanismOne way fitEasy to wireContains an earth connector GBP 22.14 1
Apollo Series 65 Optical Smoke Detector with Flashing LED and Magnetic Test Switch 55000-315APO Apollo Series 65 Optical Smoke Detector with Flashing LED and Magnetic Test Switch 55000-315APOThe Series 65 Optical Smoke Detector incorporates a pulsing LED located within the housing of the detector. The external detector moulding is identical to that of the ionisation detector and has an indicator LED which is clear in quiescent state but produces a red light in alarm.OperationThe Series 65 Optical Smoke Detector has a moulded self-extinguishing white polycarbonate case with wind resistant smoke inlets. Nickel-plated stainless-steel wiper contacts connect the detector to the base. Inside the case a printed circuit board has the optical system mounted on one side and the signal processing electronics on the other. The sensing chamber is a black moulding configured as a labyrinth which prevents penetration of ambient light. The labyrinth has a fine gauze insect-resistant cover. The chamber houses an infrared light emitting diode LED and a photo-diode which has an integral visible-light filter as extra protection against ambient light. Every three seconds the LED emits a burst of collimated light modulated at 4kHz. In clear air light from the LED does not fall directly on the diode because the LED is positioned at an obtuse angle to the diode. When smoke enters the chamber a fraction of the collimated light is scattered onto the photo-diode. If the resulting signal from the photo-diode is above a pre-set threshold the LED emits two more bursts of light this time at two-second intervals. If light is scattered onto the photo-diode by both these pulses due to the presence of smoke the detector signals an alarm state by switching the alarm latch on increasing the current drawn from the supply from about 40A to a maximum of 75mA. This fall in the impedance of the detector is recognised by the control panel as an alarm signal. The alarm current also illuminates the detector integral LED. A remote indicator connected between the L1 IN terminal and the R terminal will have a voltage equal to the supply voltage less 1 volt across it and so will illuminate. To ensure correct operation of the detector the control panel must be arranged to supply a maximum of 33 Volts dc and a minimum of 9 Volts dc in normal operation. The supply may fall to 6 Volts dc in alarm conditions if a supply current of at least 10mA is available at this voltage. To ensure effective illumination of the integral LED and any remote indicator the supply to the detector should exceed 12 Volts. To restore the detector to quiescent condition it is necessary to expel any smoke and interrupt the electrical supply to the detector for a minimum of one second.Key FeaturesResponds well to slow-burning smouldering firesWell-suited to bedrooms and escape routesUnaffected by wind or atmospheric pressureFlashing LED and magnet operated test switch option GBP 19.98 1