24 results (0,16062 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Apollo Marine Orbis BS Heat Detector - ORB-HT-41004-MAR

Apollo Orbis BS Heat Detector - ORB-HT-11004-APO

Apollo Orbis BS I.S. Heat Detector ORB-HT-51151-APO

Apollo Orbis Marine BS Heat Detector with Flashing LED ORB-HT-41016-MAR

Apollo Orbis Intrinsically Safe BS Heat Detector with Flashing LED ORB-HT-51152-APO

Apollo Orbis BS Heat Detector with Flashing LED ORB-HT-11016-APO

Apollo Orbis BS Heat Detector with Flashing LED ORB-HT-11016-APO

Apollo Orbis BS Heat Detector with Flashing LED ORB-HT-11016-APO OperationApollos Orbis heat detectors have an open-web casing which allows air to flow freely across a thermistor which measures the air temperature every 2 seconds. A microprocessor stores the temperatures and compares them with pre-set values to determine whether a fixed upper limitthe alarm levelhas been reached. In the case of rate-of-rise detectors the microprocessor uses algorithms to determine how fast the temperature is increasing. Static heat detectors respond only when a fixed temperature has been reached. Rate-of-rise detectors also have a fixed upper limit but they also measure the rate of increase in temperature. A fire might thus be detected at an earlier stage than with a static detector so that a rate-of-rise detector is to be preferred to a static heat detector unless sharp increases of heat are part of the normal environment in the area protected by the heat detector.Brand FeaturesTimeSaver Base designed for fast installationStartUp for fast commissioningFasTest reduces maintenance timeautomatic drift compensation with DirtAlert warning to easily identify dirty detectorsSensAlert which indicates that the detector is not operating properlywide voltage and operating temperature rangesoptical sensor designed for high reliability and reduced false alarm incidencemultisensory smoke detector for detecting fast-burning firesflashing LED option

GBP 15.80
1

Apollo I.S. Galvanic Barrier 29600-098

Apollo RW1000-460APO REACH Heat Detector Black Body

Apollo RW1000-400APO Reach Optical Heat Detector

Apollo SA4700-103APO Intelligent Mains Switching Input Output Unit

Apollo SA4700-302APO Intelligent DIN-Rail Input Output Unit

Apollo SA4700-102APO Intelligent Input Output Unit

Apollo XP95 Sounder VAD Base DIN-Tone with Isolator 45681-707APO

Apollo SA4700-104APO Intelligent Twin Input Output Unit

Apollo AlarmSense Base 45681-244APO

Apollo XPander 868MHz Diversity Survey Kit XPA-TE-14075-APO

Apollo AlarmSense Integrating Optical Smoke Detector with Sounder Base 55000-393APO

Apollo AlarmSense Integrating Optical Smoke Detector with Sounder Base 55000-393APO

Please note This product is obsolete but we do have limited stock available. Please contact us for further information.Apollo AlarmSense Integrating Optical Smoke Detector with Sounder Base 55000-393The AlarmSense Integrating Optical Smoke Detector works using the light scatter principle. The detector also has the ability to monitor and discard transient sources of smoke. AlarmSense is a range of conventional fire detection and alarm products designed to be connected to the same pair of supply wires making installation quicker and less expensive. AlarmSense has been developed to make the design and installation of a fire detection and alarm system easier and more economic for small to medium-sized buildings.The range also allows an existing system to be extended or modified if necessary. This flexibility makes AlarmSense an excellent choice for use in HMOs House in Multiple Occupation. As you would expect from Apollo AlarmSense incorporates features that help reduce false alarms and patented technology to ensure the integrity of a system. The range also includes products such as beacons to help meet the requirements of the Disability Discrimination Act DDA.Key FeaturesResponds well to slow-burning smouldering firesWell suited for bedrooms and escape routes360C visibility of LEDsReduces false alarmsQuick and simple installationDesigned to operate in environments where transient levels of smoke may be expectedReduces false alarms20 second delayAlarmSense FeaturesFlexibleReliableCost-effectiveCompliant with BS 5839Easy to installEasy to extend

GBP 29.43
1

Apollo AlarmSense Optical Smoke Detector 55000-390APO

Apollo AlarmSense Optical Smoke Detector 55000-390APO

Apollo AlarmSense Optical Smoke Detector 55000-390The AlarmSense Optical Smoke Detector works using the light scatter principle. The detector changes to alarm state at a pre-set threshold of smoke penetration into the sensing chamber.AlarmSense is a range of conventional fire detection and alarm products designed to be connected to the same pair of supply wires making installation quicker and less expensive. AlarmSense has been developed to make the design and installation of a fire detection and alarm system easier and more economic for small to medium-sized buildings.The range also allows an existing system to be extended or modified if necessary. This flexibility makes AlarmSense an excellent choice for use in HMOs House in Multiple Occupation. As you would expect from Apollo AlarmSense incorporates features that help reduce false alarms and patented technology to ensure the integrity of a system. The range also includes products such as beacons to help meet the requirements of the Disability Discrimination Act DDA.Brand FeaturesFlexibleReliableCost-effectiveCompliant with BS 5839Easy to installEasy to extendProduct InformationThe AlarmSense Optical Smoke Detector works using the light scatter principle. The detector changes to alarm state at a pre-set threshold of smoke penetration into the sensing chamber.Key Features Responds well to slow-burning smouldering firesWell suited for bedrooms and escape routes360C visibility of LEDsReduces false alarmsQuick and simple installation

GBP 15.76
1

Apollo AlarmSense Sounder Base 45681-510APO

Apollo AlarmSense Sounder Base 45681-510APO

Apollo AlarmSense Sounder Base 45681-510APOThe AlarmSense Sounder Base can only be used with AlarmSense systems. It is fitted with electronic circuitry to monitor the presence of detectors and signals any unauthorised removal of detector heads. It is supplied with a high or low volume setting and red or white capsare available for stand-alone installation.Brand InformationAlarmSense is a range of conventional fire detection and alarm products designed to be connected to the same pair of supply wires making installation quicker and less expensive.AlarmSense has been developed to make the design and installation of a fire detection and alarm system easier and more economic for small to medium-sized buildings. The range also allows an existing system to be extended or modified if necessary. This flexibility makes AlarmSense an excellent choice for use in HMOs House in Multiple Occupation.As you would expect from Apollo AlarmSense incorporates features that help reduce false alarms and patented technology to ensure the integrity of a system. The range also includes products such as beacons to help meet the requirements of the Disability Discrimination Act DDA.Brand FeaturesFlexibleReliableCost-effectiveCompliant with BS 5839Easy to installEasy to extendKey FeaturesAlarmSense prioritynon priority signal recognitionDetects the removal of a detector head and reports a faultContinues to work during unauthorised removal of detectorsQuick and simple installationProvides audible signal and detection at one pointHigh and low volume ranges

GBP 22.99
1

Apollo Marine Intelligent Base Mounted UVIR2 Flame Detector 55000-028MAR

Apollo Marine Intelligent Base Mounted UVIR2 Flame Detector 55000-028MAR

Apollo Marine Intelligent Base Mounted UVIR2 Flame Detector 55000-028MARThe Marine Intelligent Base Mounted UV Dual IR Flame Detector is designed to protect open indoor areas where open flaming fires may be expected. The detector has a UV and dual IR sensors responding to different wavelengths in order to discriminate between flames and spurious sources of radiation. They are used in aircraft hangers generator rooms diesel and gas turbines and paint works.OperationThe detector is sensitive to ultraviolet and low-frequency flickering infra-red radiation emitted by flames during combustion. Since it requires both UV and IR radiation the detector can operate in applications where a basic single UV or single IR detector would be inappropriate. The detector is set to respond to ultraviolet 185 - 260nm and low-frequency flickering infra-red 0.75 - 2.7ym radiation at 1 - 15Hz in order to detect all flickering flames including those invisible to the naked eye e.g. those emitted by hydrogen fires.The detector has one UV and two IR sensors responding to different wavelengths in order to discriminate between flames and spurious sources of radiation. False alarms due to electrical discharges from lightning or arc welding and flickering sunlight are minimised by combining the UVIR signals.Key FeaturesResponds to stationary flames with no flickerSensitive to low-frequency flickering IR radiation emitted by flames during combustion.Compact flame detector which fits into Discovery Marine basesLoop-poweredFalse alarms due to factors such as flickering sunlight are avoided by a combination of filters and signal processing techniques

GBP 1177.80
1

Apollo Discovery Marine Optical Smoke Detector 58000-600MAR

Apollo Discovery Marine Optical Smoke Detector 58000-600MAR

Apollo Discovery Marine Optical Smoke Detector 58000-600MARThe Discovery Marine Optical Smoke Detector works using the light scatter principle and is ideal for applications where slow-burning or smouldering fires are likely.Operating PrinciplesThe Discovery Marine Optical Smoke Detector has a white moulded polycarbonate case with wind-resistant smoke inlets.The indicator LEDs are colourless when the detector is in quiescent state and red in alarm. Within the case is a printed circuit board which on one side has the light-proof chamber with integral gauze surrounding the optical measuring system and on the other the signal processing and communications electronics.An infra-red light emitting diode within its collimator is arranged at an obtuse angle to the photo-diode. The photo-diode has an integral daylight-blocking filter.The IR LED emits a burst of collimated light every second.In clear air the photo-diode receives no light directly from the IR LED because of the angular arrangement and the chamber baffles. When smoke enters the chamber it scatters light from the emitter IR LED onto the photo-diode in an amount related to the smoke characteristics and density. The photo-diode signal is processed to provide an analogue value for transmission when the detector is interrogated.Maintenance ServiceDetectors should be maintained according to BS 5839-1 or other locally applicable code. Test Equipment can be ordered from us which can test smoke and heat detectors. Detectors should not be cleaned in the field except for careful removal of exterior dirt with a damp cloth.Key FeaturesResponds well to slow-burning smouldering firesSuitable for bedrooms and escape routesUnaffected by wind or atmospheric pressureRemote test featureRejection of transient signals

GBP 59.16
1

Apollo AlarmSense A1R Heat Detector Standard 55000-190APO

Apollo AlarmSense A1R Heat Detector Standard 55000-190APO

Apollo AlarmSense A1R Heat Detector Standard 55000-190APOThere are two heat detectors in the AlarmSense range designed to suit a wide variety of operating conditions. A static heat detector CS which responds only when a fixed temperature has been reached and a rate-of-rise detector A1R which has a fixed upper limit but in addition measures the rate of increase in temperature.AlarmSense is a range of conventional fire detection and alarm products designed to be connected to the same pair of supply wires making installation quicker and less expensive. AlarmSense has been developed to make the design and installation of a fire detection and alarm system easier and more economic for small to medium-sized buildings. The range also allows an existing system to be extended or modified if necessary. This flexibility makes AlarmSense an excellent choice for use in HMOs House in Multiple Occupation. As you would expect from Apollo AlarmSense incorporates features that help reduce false alarms and patented technology to ensure the integrity of a system. The range also includes products such as beacons to help meet the requirements of the Disability Discrimination Act DDA.Brand FeaturesFlexibleReliableCost-effectiveCompliant with BS 5839Easy to installEasy to extendProduct InformationThere are two heat detectors in the AlarmSense range designed to suit a wide variety of operating conditions. A static heat detector CS which responds only when a fixed temperature has been reached and a rate-of-rise detector A1R which has a fixed upper limit but in addition measures the rate of increase in temperature.Key Features Can be used for applications where smoke detectors are unsuitableIdeal environments that are dirty or smoky under normal conditionsCS detectors are ideal for use in environments with rapid temperature fluctuations such as boiler rooms360C visibility of LEDsReduction offalse alarmsQuick and simple installation

GBP 12.85
1

Apollo Discovery CO Heat Multisensor 58000-305APO

Apollo Discovery CO Heat Multisensor 58000-305APO

Apollo Discovery CO Heat Multisensor 58000-305APOThe Discovery COHeat Multisensor Detector is good at detecting deep-seated smouldering fires which give off a lot of CO as well as flaming fires. They are ideal for use in hotel bedrooms where steam may bepresent dusty environments or even where simulated smoke may bepresent.The Discovery COHeat Multisensor Detector contains a CO detection cell and a thermistor temperature sensor whose outputs are combined to give the final analogue value. The way in which the signals from the two sensors are combined depends on the response mode selected. The COHeat Multisensor detects the presence of carbon monoxide or heat or a combination of both. The Multisensor construction is similar to that of a CO detector but uses a different lid in order to expose the thermistor to the surrounding air. The signals from the CO sensing cell and the thermistor are independent and represent the amount of CO or the temperature present in the vicinity of the detector. When the detector is used in heat only mode Mode 5 it operates as an A1R rate-of-rise heat detector with a static threshold of 58C.Brand InformationDiscovery is a range of high-specification analogue addressable fire detectors and alarm devices. Discovery detectors offer effective false alarm management by a combination of EN 54 approved operating modes and sophisticated algorithms. Drift compensation further reduces the likelihood of false alarms caused by a build-up of dust in the sensing chamber.In addition to the familiar smoke and heat detectors the Discovery range features two multisensor detectors. One is an opticalheat multisensor which can be used to protect against many types of fire risk. The other is a carbon monoxideheat multisensor which protects against both smouldering fires and those generating heat.Operating PrinciplesDiscovery detectors are designed to be operated with purpose-designed control and indicating equipment that makes full use of their features. Discovery can however be connected to any fire control panel which can operate existing ranges of Apollo analogue addressable detectors with the previously noted rule that the control and indicating equipment must not have a drift algorithm operating on Discovery devices. Contact the fire control panel manufacturer for guidance.Maintenance ServiceDetectors should be maintained according to BS 5839- or other locally applicable code. Test equipment can be ordered from us which can test smoke and heat detectors.Key Features Responds to smouldering and flaming firesLess susceptible to false alarms caused by steam and dustFive response modesRemote test feature

GBP 77.17
1

Apollo Discovery Heat Detector 58000-400APO

Apollo Discovery Heat Detector 58000-400APO

Apollo Discovery Heat Detector 58000-400APOThe Discovery Heat Detector uses a single thermistor to sense the air temperature around the detector.Discovery heat detectors have a common profile with ionisation and optical smoke detectors but have a low air flow resistance case made of self-extinguishing white polycarbonate. For the European standard version of the detector the five modes correspond to five classes as defined in EN 54-5. The classes in this standard correspond with different response behaviour each of which is designed to be suitable for a range of application temperatures. All modes incorporate fixed temperature response which is defined in the standard by the static response temperature.Application EnvironmentsCarpark Loading BaysDusty EnvironmentsHospitalsHotelsMedium to Large BuildingsOfficesUniversity CampusesWarehousesBrand InformationDiscovery is a range of high-specification analogue addressable fire detectors and alarm devices. Discovery detectors offer effective false alarm management by a combination of EN 54 approved operating modes and sophisticated algorithms.Drift compensation further reduces the likelihood of false alarms caused by a build-up of dust in the sensing chamber.In addition to the familiar smoke and heat detectors the Discovery range features two multisensor detectors. One is an opticalheat multisensor which can be used to protect against many types of fire risk. The other is a carbon monoxideheat multisensor which protects against both smouldering fires and those generating heat.Electrical ConsiderationsThe Discovery Heat Detector uses a single thermistor to sense the air temperature at the detector position. The thermistor is connected in a resistor network which produces a voltage output dependent on temperature. The design of the resistor network together with the processing algorithm in the microcontroller gives an approximately linear characteristic from 10C to 80C. This linearised signal is further processed depending on the response mode selected and converted to an analogue output.Operating PrinciplesDiscovery detectors are designed to be operated with purpose-designed control and indicating equipment that makes full use of their features. Discovery can however be connected to any fire control panel which can operate existing ranges of Apollo analogue addressable detectors with the previously noted rule that the control and indicating equipment must not have a drift algorithm operating on Discovery devices. Contact the fire control panel manufacturer for guidance.CommunicationDiscovery uses a digital communications protocol which has been developed from the XP95 protocol but differs in that it allows communication in three different modes Normal Read and Write to allow a more extensive exchange of information and commands than previous analogue addressable ranges. In addition discovery can store data in non-volatile memory.- The Normal mode is identical to the XP95 protocol with the exception that the five additional analogue value bits in the XP95 protocol extension have been re-defined so that the fire control panel is able to distinguish between Discovery and XP95 devices.- The Read mode is used to check information stored in the non-volatile memory of each detector. It is accessed by using a simple extension to the Normal mode communication method from the fire control panel to the detector.- In Write mode the fire control panel is able to write information to the detector by extending the communication method in the same way as in Read mode. During Read or Write modes a detector can signal an alarm by means of the alarm flag and alarm address bits.Discovery detectors are compatible with XP95 and Soteria. It should be noted however that Discovery features will not be available when Discovery is used with XP95 fire control panels. Fire control panels with drift compensation algorithms should disable the algorithms when communicating with Discovery.For fire control panels running CoreProtocol please refer to the fire control panel manufacturers operating instructions.Maintenance ServiceDetectors should be maintained according to BS 5839-1 or other locally applicable code. Test Equipment can be ordered from us which can test smoke and heat detectors.Detectors should not be cleaned in the field except for careful removal of exterior dirt with a damp cloth.EMC Directive 2004108ECThe Discovery Heat Detector complies with the essential requirements of the EMC Directive 201430EU provided that it is used as described in this datasheet.A copy of the Declaration of Conformity is available upon request.Key Features Ideal in environments that are dirty or smoky under normal conditionsWell suited for warehouses loading bays and car parksUnaffected by wind or atmospheric pressureFive response modesRemote test feature

GBP 41.56
1