Apollo Discovery Marine Waterproof Manual Call Point 58200-975MAR Apollo Discovery Marine Waterproof Manual Call Point 58200-975MARThe Discovery Marine Manual Call Points has been designed for use in marine and offshore environments and are available in two versions for indoor and outdoor applications. Both versions are available with and without short circuit isolators.An alarm is initiated by pressing the resettable element. The Manual Call Point signals to the Control and Indicating Equipment using an interrupt feature within the Apollo Digital Protocol. An alarm status is indicated by a yellow and black bar in the lower section of the resettable element and a red LED. The Manual Call Point can be easily reset from the front using the supplied reset key.Brand InformationDiscovery Marine analogue addressable fire detectors are suitable for larger vessels. The high specification range has been developed to meet the requirements of sophisticated systems. Discovery gives you total reassurance in installations where it is necessary to adapt detection to different operating environments and where protection against unwanted alarms is paramount.Key FeaturesResettable operating elementEasy access front reset mechanismFront facing accessible addressing for commissioningErgonomic reset key and keyring holeFlashing Poling LED Option170 viewable LED indicator GBP 157.60 1
Apollo SA5900-928MAR Intelligent Marine Manual Call Point Apollo SA5900-928MAR Intelligent Marine Manual Call PointThe Intelligent Marine Manual Call Point MCP has been designed to operate on a loop of intelligent fire detection devices. An alarm is initiated by pressing the resettable element. The MCP signals to the Fire Control Panel using an interrupt feature within the Apollo Digital Communication Protocol. An alarm status is indicated through the rotation of the resettable element displaying yellow and black indication bars and a solid red LED. The MCP can be easily reset from the front using the supplied reset key. The Intelligent Marine MCP is intended for indoor marine and offshore applications and has a built-in short circuit isolator.OperationThe address of each call point is set at the commissioning stage by means of a DIL switch. A solid red alarm LED is provided on the manual call point. This LED is controlled independently of the call point by the control panel. The LED will flash yellow if there is a fault and flash green when the device is polled. Discovery and CoreProtocol configurable. Once activated the Intelligent Marine Manual Call Point SIL Approved can be reset by inserting the reset key into the front facing LED turning clockwise until a positive click and reset occurs.The Intelligent Marine Manual Call Point incorporates a short circuit isolator which will ensure its operation in the event of a short circuit fault on the loop. Isolator operation is indicated by a solid yellow LED.Key FeaturesResettable element for testingEasy access front reset mechanismA unique ergonomically designedKey for resetting and front cover removal GBP 53.21 1
Apollo Discovery Marine Weatherproof Manual Call Point 58200-976MAR Apollo Discovery Marine Weatherproof Manual Call Point 58200-976MARThe Discovery Marine Manual Call Points has been designed for use in marine and offshore environments and are available in two versions for indoor and outdoor applications. Both versions are available with and without short circuit isolators.An alarm is initiated by pressing the resettable element. The Manual Call Point signals to the Control and Indicating Equipment using an interrupt feature within the Apollo Digital Protocol. An alarm status is indicated by a yellow and black bar in the lower section of the resettable element and a red LED. The Manual Call Point can be easily reset from the front using the supplied reset key.Discovery Marine analogue addressable fire detectors are suitable for larger vessels. The high specification range has been developed to meet the requirements of sophisticated systems. Discovery gives you total reassurance in installations where it is necessary to adapt detection to different operating environments and where protection against unwanted alarms is paramount.OperationThe address of each call point is set at the commissioning stage by means of a seven-segment DIL switch. On the indoor versions the address switch is accessible without removing the call point from the mounting surface. A red alarm LED is provided on the call point. This LED is controlled independently of the call point by the control panel.This Manual Call Point helps reduce installation time as all the initial installation cabling is wired to a terminal block which fits neatly in the back of the call point. Once activated the Discovery Marine Manual Call Point can be reset by inserting the reset key into the front facing LED turning clock wise until a positive click and reset occurs.Key FeaturesApproved for use in the marine environmentFive response modes for environmental adaptationDaynight switching for increased flexibilityDrift compensation for false alarm reductionUser programmability for dataXPERT card addressing for increased security GBP 153.76 1