Apollo SA5100-710APO Soteria Multi-Sensor Detector Dual OpticalHeat Apollo SA5100-710APO Soteria Multi-Sensor Detector Dual OpticalHeatThe Apollo SA5100-710APO Soteria Multi-Sensor Detector Dual OpticalHeat uses advanced dual optical sensing technology to accurately detect smoke particles entering the chamber and a central heat thermistor for detecting heat. It has five different operating modes giving you the option to adapt the detector to suits it environment.Key Features of the SA5100-710APOAvailable with integrated switchable isolatorDrift compensationTricoloured LED status indicatorFasTest for quicker testing of detectorsLocking mechanism grub screwDIL Switch Addressing GBP 48.30 1
Apollo Protocol Translator Dual Channel 55000-856APO Apollo Protocol Translator Dual Channel 55000-856APOThe Protocol Translator are installed in the safe area ensuring integrity of communication between control equipment and field devices and safety within the limits of BASEEFA approvals. GBP 163.55 1
Apollo SA5100-810APO Soteria Tri-Sensor Detector Dual OpticalHeatCO Apollo SA5100-810APO Soteria Tri-Sensor Detector Dual OpticalHeatCOThe Soteria Tri-Sensor Detector Dual OpticalHeatCO uses advanced dual optical sensing technology to accurately detect smoke particles and discriminate against false alarm stimuli. It has a centrally located heat thermistor along with a CO sensor giving you three methods of detection.The detector can operate in 5 modes of sensitivity.Soteria detectors have been designed to operate on Discovery loops. This allows for Soteria detectors and bases to operate on existing systems and for Soteria detectors to operate on Discovery bases XPERT 7 Intelligent Mounting Base.Key FeaturesAvailable with integrated switchable isolatorDrift compensationTricoloured LED status indicatorFasTest for quicker testing of detectorsLocking mechanism grub screwDIL Switch Addressing GBP 67.08 1
Apollo Dual Switch Manual Call Point SA5900-011APO Apollo Dual Switch Manual Call Point SA5900-011APOThe Apollo Dual Switch Manual Call Point provides volt free double pole change-over contacts suitable for normally open or normally closed multiple switching from a single activation point. A device is activated by pressing the resettable element. An activation status is indicated through the rotation of the resettable element displaying yellow and black indication bars. The manual call point can be easily reset from the front using the supplied reset key.Key FeaturesResettable operating elementEasy access front reset mechanismErgonomic reset keyDouble pole change-over contactsSuitable for semi flush or surface mountingOptional transparent hinged cover GBP 16.68 1
Apollo Intelligent Base Mounted UV Dual IR Flame Detector 55000-023APO Apollo Intelligent Base Mounted UV Dual IR Flame Detector 55000-023APOThe Intelligent Base Mounted UV IR Flame Detector is designed to protect open indoor areas such as aircraft houses generator rooms and paint workswhere open flaming fires may be expected. The detector has a UV and dual IR sensors responding to different wavelengths in order to discriminate between flames and spurious sources of radiation.Key FeaturesResponds to stationary flames with no flickerSensitive to UV and low-frequency flickering IR radiation emitted by flames during combustionCompact flame detector whichfits intoDiscovery or XP95 basesLoop-poweredFalse alarms due to electrical discharges from lightning or arc welding and flickering sunlight are minimised GBP 937.60 1
Apollo XP95 DIN-Rail Dual Isolator - 55000-802APO Apollo XP95 DIN-Rail Dual Isolator - 55000-802APOThe DIN-Rail Dual Isolator provides two independent isolators which sense and isolate short circuits on Discovery and XP95 loops and spurs.OperationUnder normal operating conditions a low impedance is present between the two negative terminals of each isolator channel so that power and signals are passed to the next base in line. If a short-circuit or abnormally low impedance occurs across the loop the fall in voltage is sensed and the isolator isolates the negative supply in the direction of the fault. In this condition the yellow LED of the affected channel will be illuminated.The isolated section of loop is tested using a current pulse every five seconds. When the short-circuit is removed the power will automatically be restored. The two isolator channels are not interconnected internally and operate completely independently of one another.Key FeaturesLoop-poweredPolarity sensitiveUp to 20 detectors can be installed between isolatorsAllows fully isolated spurs GBP 55.00 1
Apollo Exd Conventional UV Dual IR Flame Detector 55000-065APO Apollo Exd Conventional UV Dual IR Flame Detector 55000-065APOThe Flameproof UVIR2 Flame Detector is designed for hazardous environments in either indoor or outdoor applications where open fires may be expected. False alarms from flickering sunlight arc welding or lightning are avoided by the combination of UV and dual IR signal processing techniques.It detects almost all flames including those invisible to the naked eye e.g. hydrogen fires. Certified by ISSOP for compliance with standards EN50014 EN50018 and EN50281. Key Features ATEX Certified II 2 G DCENELECIEC Certified EEx d - IIC T6- Zones 1 21 2 and 22Class 1 sensitivity to EN54-10 detects 0.1m2 fires at 25mHighest optical interference immunitySelectable output options Conventional two-wire 4-20mA Relay Contacts - FireFault Pre alarm Latching or Non-latchingSelectable response speedRemote control self-testLow power consumptionIP66 ratedSupply voltage 14 to 30VdcOperating temperature -10C to 55C GBP 2340.00 1
Apollo Marine DIN-Rail Dual Isolator 55000-770MAR Apollo Marine DIN-Rail Dual Isolator 55000-770MARThe Marine DIN-Rail Dual Isolator provides in one housing two independent isolators which sense and isolate short-circuits on loops and spurs. This unit needs to be installed in a suitable enclosure Part No. 29600-239240 or equivalent and secured using the end stops.OperationThe isolators are loop-powered and are polarity sensitive. A maximum of twenty detectors may be installed between isolators. When a short-circuit condition exists on either side of the isolator the yellow LED is illuminated.Under normal operating conditions a low impedance is present between the two negative terminals of each isolator channel so that power and signals are passed to the next base in line.If a short-circuit or abnormally low impedance occurs across the loop the fall in voltage is sensed and the isolator isolates the negative supply in the direction of the fault. In this condition the yellow LED of the affected channel will be illuminated. The isolated section of loop is tested using a current pulse every five seconds. When the short-circuit is removed the power will automatically be restored.Key FeaturesLoop-poweredUp to 20 detectors can be installed between isolatorsAllows fully isolated spurs GBP 78.92 1
Apollo Conventional Dual IR Flame Detector 55000-060APO Apollo Conventional Dual IR Flame Detector 55000-060APOThe IR2 Flame Detector is designed for harsh environments in indoor applications. The detector has two sensors which respond to different IR wavelengths to discriminate between flames and spurious sources of radiation.Key Features Selectable output options Conventional two-wire 4-20mA Latching or Non-latching RelayContacts - FireFault Pre alarmClass 1 sensitivity to EN54-10 detects 0.1m2 fire at 25mHigh optical interference immunitySelectable response speedOptical self-testLow power consumptionIP65 ratedSupply voltage 14 to 30VdcOperating temperature -10C to 55C GBP 1494.48 1
Apollo Intelligent Dual IR Flame Detector 55000-280APO Apollo Intelligent Dual IR Flame Detector 55000-280APOThe Intelligent IR Flame Detector is designed for use in areas where flaming fires may be expected. The detector has two sensors which respond to different IR wavelengths to discriminate between flames and spurious sources of radiation. Applications include aircraft hangars coal handling and paper manufacturing plants and woodworking environments.Key Features Sensitive to flickering IR radiationDetects through films of oil dust water and iceResponds to flickering flames including those invisible to the naked eyeCompatible with Discovery and XP95 protocolsRemote optical self-test function90 field of viewUp to 40m coverage GBP 1747.20 1
Apollo Conventional UV Dual IR Flame Detector 55000-064APO Apollo Conventional UV Dual IR Flame Detector 55000-064APOThe combination of UV and IR2 detection plus signal processing allows the sensor to be used without risk of false alarms in difficult situations characterised by factors such as flickering blackbody by radiation or arc welding. Key FeaturesSelectable output options Conventional two-wire 4-20mA Latching or Non-latching Relay Contacts - FireFault Pre alarmClass 1 sensitivity to EN54-10 detects 0.1m2 fire at 25mHigh optical interference immunitySelectable response speedOptical self-testLow power consumptionIP65 ratedSupply voltage 14 to 30VdcOperating temperature -10C to 55COperating temperature -10C to 55C GBP 2152.80 1
Apollo Exd Conventional Dual IR Flame Detector 55000-061APO Apollo Exd Conventional Dual IR Flame Detector 55000-061APOThe Flameproof IR2 Flame Detector is designed for use in hazardous environments in indoor applications. The combination of filters and signal processing allows the sensor to be used with a very low risk of false alarms in difficult situations characterised by factors such as flickering lights. Baseefa has certified the detector for compliance to standards EN 60079-0 EN 60079-1 and EN 61241-1 Key Features ATEX IECEx certified II2GD Ex d IIC T4 Gb EE tb IIICT135 C Db IP66 A21 Zones 1 21 2 and 22Selectable output options Conventional two-wire 4-20mA Latching or Non-latching Relay Contacts - FireFault Pre alarmClass 1 sensitivity to EN54-10 detects 0.1m2 fire at 25mHigh optical interference immunitySelectable response speedOptical self-testLow power consumptionIP66 ratedSupply voltage 14 to 30VdcOperating temperature -10C to 55C GBP 2129.40 1
Apollo XPander Dual Input Output Channel Unit - XPA-IN-14012-APO Apollo XPander Dual Input Output Channel Unit - XPA-IN-14012-APOThe XPander InputOutput Unit is a radio based interface and offers two monitored input circuits and two relay outputs. It can be used for controlling fire doors fire dampers smoke vents and other fire engineering applications.Brand InformationXPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. It communicates with the control panel using the Apollo addressable two-wire power and communications system. The interface communicates with the detection and alarm signalling devices by means of radio waves.The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface. The detectors incorporate drift compensation and report any compensation limit occurring. The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.Key FeaturesWirelessMonitored switch circuitVoltage-free contacts Capable of switching up to 30V at 1AFive-year battery life using standard AA alkaline batteries GBP 237.64 1
Apollo RW1000-760APO REACH Multi-Sensor Detector OpticalHeat Black Body Apollo RW1000-760APO REACH Multi-Sensor DetectorOpticalHeat Black BodyThe RW1000-760APO is a wireless addressable dual-optical andheat detection multi-sensor detector offering both technologies for improvedperformance and high levels of false-alarm rejection.Operating PrinciplesThe REACH Multi-sensor Detector features a dual-chamber opticalsmoke sensor and rate-of-rise A1R heat detector. Alarm is triggered based onan algorithm that considers both sensor readings.Key FeaturesTwin alarm bi-colour LEDs for 360 visibilityAdvanced dual-optical chamber designAdvanced drift compensationHeat detection - rate-of-rise A1RBi-directional wireless communicationDual-channel redundancyTen-year battery life GBP 202.97 1
Apollo RW1000-600APO Reach Optical Smoke Detector Apollo RW1000-600APO Reach Optical Smoke DetectorThe RW1000-600APO is a wireless addressable optical smoke detector that utilised dual-optical smoke detection technology for improved performance maintaining the highest levels of false-alarm rejection.The REACH range of products have been designed to solve challenging installation scenarios for structures with restricted or complex access and installation conditions such as listed buildings out-buildings temporary structures where wired installation or long site downtime is not possible.Key FeaturesTwin alarm bi-colour LEDs for 360 visibilityAdvanced dual-optical chamber designAdvanced drift compensationBi-directional wireless communicationDual channel redundancyTen year battery lifeFive year product warranty GBP 162.61 1
Apollo RW1000-660APO REACH Optical Smoke Detector Black Body Apollo RW1000-660APO REACH Optical Smoke Detector Black BodyThe RW1000-660APO is a wireless addressable optical smokedetector that utilises dual-optical smoke detection technology for improvedperformance maintaining the highest levels of false-alarm rejection.Device AddressingDevice addressing is handled by the REACH WirelessLoop Interface device RW1700-030APO.Devices are soft-addressed automatically when pairing withthe Loop Interface and can be changed manually. Hard-addressing using ApolloXPERT cards are not supported.CommunicationREACH Wireless Devices use radio-frequency wireless communicationto connect to the Loop-Interface.The Loop-Interface RW1700-030APO translates the wireless communicationinto wired Apollo protocol communication with each device addressableindividually by the fire panel. Tamper detectionREACH Wireless devices contain an anti-tamper mechanism. In theevent of removal from its base it sends a tamper detection message to theLoop-Interface.Key FeaturesTwin alarm bi-colour LEDs for 360 visibilityAdvanced dual-optical chamber designAdvanced drift compensationBi-directional wireless communicationDual-channel redundancyTen-year battery life GBP 178.81 1
Apollo Series 65 CS Heat Detector with Flashing LED 55000-136APO Apollo Series 65 CS Heat Detector with Flashing LED 55000-136APOThe Series 65 Heat Detector monitors temperature by using a dual thermistor network which provides a voltage output proportional to the external air temperature. There are 12 heat detectors in the Series 65 range designed to suit a wide variety of operating conditions.Key FeaturesCan be used for applications where smoke detectors are unsuitableIdeal for environments that are dirty or smoky under natural conditionsWide operating voltageFlashing LED and magnet operated test switch option GBP 14.72 1
Apollo Series 65 A1R Heat Detector with Flashing LED 55000-121APO Apollo Series 65 A1R Heat Detector with Flashing LED 55000-121APOThe Series 65 Heat Detector monitors temperature by using a dual thermistor network which provides a voltage output proportional to the external air temperature. There are 12 heat detectors in the Series 65 range designed to suit a wide variety of operating conditions.Key FeaturesCan be used for applications where smoke detectors are unsuitableIdeal for environments that are dirty or smoky under natural conditionsWide operating voltageFlashing LED and magnet operated test switch option GBP 14.00 1
Apollo MiniDisc Remote Indicator 53832-070APO Apollo MiniDisc Remote Indicator 53832-070APOThe MiniDisc Remote Indicator is a light-weight compact red LED indicator for use in fire protection systems. The MiniDisc remote indicator is only 20mm high and 80mm in diameter. It comprises two partsthe base which is installed onto a wall or soffit and the lid which is fitted to the base with a bayonet lock. An anti-tamper screw in the lid locks the unit together. Two pairs of keyholes are providedone for 50mm and the other for 60mm fixing centres.Key FeaturesCan be used across the entire Apollo rangeSmall and discreteAnti-tamper screw to protect against unauthorised removal GBP 5.16 1
Apollo Marine Intelligent Base Mounted UVIR2 Flame Detector 55000-028MAR Apollo Marine Intelligent Base Mounted UVIR2 Flame Detector 55000-028MARThe Marine Intelligent Base Mounted UV Dual IR Flame Detector is designed to protect open indoor areas where open flaming fires may be expected. The detector has a UV and dual IR sensors responding to different wavelengths in order to discriminate between flames and spurious sources of radiation. They are used in aircraft hangers generator rooms diesel and gas turbines and paint works.OperationThe detector is sensitive to ultraviolet and low-frequency flickering infra-red radiation emitted by flames during combustion. Since it requires both UV and IR radiation the detector can operate in applications where a basic single UV or single IR detector would be inappropriate. The detector is set to respond to ultraviolet 185 - 260nm and low-frequency flickering infra-red 0.75 - 2.7ym radiation at 1 - 15Hz in order to detect all flickering flames including those invisible to the naked eye e.g. those emitted by hydrogen fires.The detector has one UV and two IR sensors responding to different wavelengths in order to discriminate between flames and spurious sources of radiation. False alarms due to electrical discharges from lightning or arc welding and flickering sunlight are minimised by combining the UVIR signals.Key FeaturesResponds to stationary flames with no flickerSensitive to low-frequency flickering IR radiation emitted by flames during combustion.Compact flame detector which fits into Discovery Marine basesLoop-poweredFalse alarms due to factors such as flickering sunlight are avoided by a combination of filters and signal processing techniques GBP 1177.80 1
Apollo Series 65 CR Heat Detector with Flashing LED 55000-131APO Apollo Series 65 CR Heat Detector with Flashing LED 55000-131APOThe Series 65 Heat Detector monitors temperature by using a dual thermistor network which provides a voltage output proportional to the external air temperature. There are 12 heat detectors in the Series 65 range designed to suit a wide variety of operating conditions.Brand InformationSeries 65 incorporates well-proven sensing technologies including an Integrated Circuit based on that used in XP95 analogue addressable detectors. The Series 65 range has a wide operating voltage of 933V and consists of ionisation integrating ionisation and optical smoke detectors four grades of heat detector and a range of bases.Key FeaturesCan be used for applications where smoke detectors are unsuitableIdeal for environments that are dirty or smoky under natural conditionsWide operating voltage GBP 14.72 1
Apollo XPander Remote Indicator Module - XPA-IN-14102-APO Apollo XPander Remote Indicator Module - XPA-IN-14102-APODesigned and manufactured using the latest techniques and surface-mount technology to ensure component count is kept to a minimum whilst maximising reliability the XPander Remote Indicator Module is used to indicate the activation of an individual device or zone.Brand InformationThe device is powered by a low-voltage dual supply alkaline battery pack which has been tested to provide a five-year life at normal conditions 15C to 35C the condition of which is continually monitored. The system indicates the remaining battery capacity with a low battery condition being indicated as a fault allowing 30 days for the battery pack to be changed before unit failure occurs.An additional warning is also given seven days before unit failure occurs. Removal of the remote indicator from the fixing plate will indicate a fault condition. The device is fully compliant with EN 54-25 and incorporates a locking screw to prevent unauthorised removal. GBP 209.51 1
Apollo Series 65 BR Heat Detector with Flashing LED - 55000-126APO Apollo Series 65 BR Heat Detector with Flashing LED - 55000-126APOThe Series 65 Heat Detector monitors temperature by using a dual thermistor network which provides a voltage output proportional to the external air temperature. There are 12 heat detectors in the Series 65 range designed to suit a wide variety of operating conditions.Brand InformationSeries 65 incorporates well-proven sensing technologies including an Integrated Circuit based on that used in XP95 analogue addressable detectors. The Series 65 range has a wide operating voltage of 933V and consists of ionisation integrating ionisation and optical smoke detectors four grades of heat detector and a range of bases.Key FeaturesCan be used for applications where smoke detectors are unsuitableIdeal for environments that are dirty or smoky under natural conditionsWide operating voltage Flashing LED and magnet operated test switch optionProduct CodesDescriptions55000-126APOSeries 65 BR Heat Detector with Flashing LED55000-125APOSeries 65 BR Heat Detector with Flashing LED and Magnetic Test Switch55000-131APOSeries 65 CR Heat Detector with Flashing LED GBP 14.72 1
Apollo Series 65 BR Heat Detector - 55000-127APO Apollo Series 65 BR Heat Detector - 55000-127APOThe Series 65 Heat Detector monitors temperature by using a dual thermistor network which provides a voltage output proportional to the external air temperature. There are 12 heat detectors in the Series 65 range designed to suit a wide variety of operating conditions. Apollo Series 65 smoke heat detector range are a direct replacement for the earlier Series 60 devices. Series 65 detectors have a wide voltage range 9-33 volt DC and can be integrated on to security systems when used with the 12 volt relay base 45681-508.The heat detector operates by using a matched pair of thermistors to sense heat. One thermistor is exposed to the ambient temperature the other is sealed. In normal conditions the two thermistors register similar temperatures but on the development of a fire the temperature recorded by the exposed thermistor will increase rapidly resulting in an imbalance of the thermistors and causing the detector to change to the alarm state.A1R BR and CR are Rate of Rise detectors designed to detect a fire as the temperature increases but they also have a fixed upper limit at which the detector will go into alarm if the rate of temperature increase has been too slow to trigger the detector earlier.Key Features Can be used for applications where smoke detectors are unsuitableIdeal for environments that are dirty or smoky under natural conditionsWide operating voltageFlashing LED and magnet operated test switch option GBP 14.72 1
Apollo Series 65 CS Heat Detector - 55000-137APO Apollo Series 65 CS Heat Detector - 55000-137APOThe Series 65 Heat Detector monitors temperature by using a dual thermistor network which provides a voltage output proportional to the external air temperature. There are 12 heat detectors in the Series 65 range designed to suit a wide variety of operating conditions. Apollo Series 65 smoke heat detector range are a direct replacement for the earlier Series 60 devices. Series 65 detectors have a wide voltage range 9-33 volt DC and can be integrated on to security systems when used with the 12 volt relay base 45681-508.The heat detector operates by using a matched pair of thermistors to sense heat. One thermistor is exposed to the ambient temperature the other is sealed. In normal conditions the two thermistors register similar temperatures but on the development of a fire the temperature recorded by the exposed thermistor will increase rapidly resulting in an imbalance of the thermistors and causing the detector to change to the alarm state.A1R BR and CR are Rate of Rise detectors designed to detect a fire as the temperature increases but they also have a fixed upper limit at which the detector will go into alarm if the rate of temperature increase has been too slow to trigger the detector earlier.Key Features Can be used for applications where smoke detectors are unsuitableIdeal for environments that are dirty or smoky under natural conditionsWide operating voltageFlashing LED and magnet operated test switch option GBP 14.72 1