Aico Plug-in RadioLINK module Ei200MRF Aico Plug-in RadioLINK module Ei200MRFThe Ei200MRF is a module that fits into Ei208W battery Carbon Monoxide alarm so that the unit can use RadioLINK interconnection to link with other alarms. The module simply plugs into the designated slot in the base of the alarm head with flashing LEDs indicating that the module has been fitted correctly.As with other RadioLINK products the once the Ei200MRF module has been fittedthe alarmwill need to belinked into the alarm system or House Coded. View ourstep by step guide to House Coding here.Technical SpecificationSupply Voltage 3V lithium battery.RF frequency 868.499Mhz RadioLINK protocol.RF Power 10dBm.RF Protocol Proprietary RadioLINK using multi-path multi-repeater mesh architecture.RF Range 100 Meters in free air.System Size 12 RadioLINK devices max.Operating Temperature 0 to 40C. Storage 0 to 35C in a dry area.Humidity Range 15 to 95 relative humidity.IndicatorsBlue LED Typically RF transmission house code mode indicator code reset.Green LED Typically monitoring mode indicator alternating with blue LED to indicate monitoring success.Red LED Typically monitoring mode cancel alternating with blue LED to indicate monitoring failure.Dimensions Product 60mm x 30mm x 20mm.Weight 25g.Guarantee 5 years limited guarantee.Approvals CE certified EN 300220-2 Radio EN301489-3 EMC EN624792010 Safety. GBP 74.56 1
Aico EI650iRF RadioLINK Optical Smoke Alarm - 10 Year Lithium Battery Powered - With AudioLink Aico EI650iRF RadioLINK Optical Smoke Alarm - 10 Year Lithium Battery Powered - With AudioLink The Ei650iRF is a battery-powered Optical Smoke Alarm. It is able to wirelessly interconnect with any other RadioLINK RadioLINK and SmartLINK products. Contains an Optical Smoke ChamberThe Ei650iRF RadioLINK Optical Smoke Alarm is best for detecting slow smouldering fires commonly produced by electrical fires or sofas and is less likely to react to cooking smells if fitted in the hallway next to the kitchen.Battery and LifespanThis battery powered alarm contains sealed in tamper-proof lithium battery that will last for the full 10-year life of the alarm. The alarm is not powered until it is twisted on the mounting base thus avoiding battery power consumption during storage and prior to installation.Built-in RadioLINK Wireless Interconnection TechnologyRadioLINK wireless interconnection technology is built-in to this alarm. RadioLINK uses Radio Frequency signals to link alarms together with added functionality. All RadioLINK alarms and devices should be House Coded together upon install.Key FeaturesOptical sensor with dust compensation technologyBuilt-in AudioLINKUses built-in RadioLINK technology to interconnect and for data extractionConnects wirelessly with all other Aico wireless interconnection productsBattery powered with a sealed-in lithium batteryEasy to fit twist on base and multi-fixings with an anti-tamper locking option10-year lifeGrade F1 and compliant with Scottish legislationKitemarked to BS EN 146042005 GBP 94.61 1
Aico EI1000G SmartLINK Gateway - Mains with Lithium Back-up Aico EI1000G SmartLINK Gateway - Mains with Lithium Back-upThe SmartLINK Gateway is designed for use with the Aico RF devices. It provides a mechanism to transfer information from the RF network to a portal over the GSM network.It is mains powered with a rechargeable battery backup that can provide up to 72hrs of power supply in case of mains failure.Connected devices events are processed by the Gateway as they occur and cover events such asFire AlarmCO level detected High Medium LowButton TestMains Absent FaultHead OKHead RemovedEnd of lifeTo ensure the safety of the data it is encrypted in both directions during transmission using AES128 encryption.In addition for ease of installation the SmartLINK App available on Android iOS provides a step-by-step guide for the installation of the Gateway and the Aico RF devices.All data sent is accessible from a web portal where alerts can be set up to be delivered by email or SMS. Reports can also be run from the web portal to facilitate the management of the Alarms fitted.The data on the portal is securely stored and is only available to the associated client.Key FeaturesEnables remote management of RF AlarmsReceives RF specific data from RF devicesTransmits data over GSM networkNot GSM provider dependentBidirectional data encryptionUnique House Coding featureEasy setup and configurationCompatible with SmartLINK RadioLINKProvides specific data from radio frequency devicesHeart beat every 12 hours which gets sent to the portalTo connect to your smart device and portal you simply scan QR codes on alarm and moduleEasy installation and configurationTransmits data over GSM networkUnique house coding featureData upload 2G GSM network roaming sim card supplied no subscription necessaryFrequency 868MHz band 1 duty cyclePower usage 40mAVoltage 230VBattery back-up Rechargeable batteryProtocol Proprietary RF Protocol using multi-path multi-repeater mesh architectureRF Range 100 metres in free air depending on obstructionsNumber of devices Up to 12 RF devicesIndicator LEDs 3 colour LED blue green and redData requirements Monitoring via Ei1000G gateway download via EiUSB1Operating temperature -10C to 40CHumidity range 15 to 95 relative humidityMaterial PlasticHeight 150mmWidth 145mmDepth 55mm GBP 350.89 1
Aico RadioLINK Relay Module with 5A Relay amp Rechargeable Battery Back-up Ei428 Aico RadioLINK Relay Module with 5A Relay Rechargeable Battery Back-up Ei428The Ei428 is a mains powered relay module that triggers external devices such as a strobe light or telecare deviceif the alarmsin the propertyactivate.For use with 140RC when using anEi168Rc RadioLINK base160ewhen using andEi100MRF RadioLINK module Ei3000 series when using anEI3000MRF SmartLINK moduleor any RadioLINK enabled CO alarms.The module has additional trunking knock outsto make as easy to install as possibleand is designed to fit underneath the space of easi-fit or RadioLINK base. However a cover Ei128COV is available if needed and containsa set of volt free contacts as standard.The replay module can beconfigured to give a 230V output or a 24V output using an external 24V supplyOperation of Ei428 RadioLINK Relay ModuleOn receiving a RadioLINK signal from one of the alarms in the system the relay contacts will be operated causing a signal to be sent to the system to which it is connectedThe indicator on the cover will show a constant green light when the mains power is connected.Technical SpecificationA relay module with cover to allow flexibility in siting.For use with 140RC when using anEi168Rc RadioLINK base160ewhen using andEi100MRF RadioLINK module Ei3000 series when using anEI3000MRF SmartLINK moduleor any RadioLINK enabled CO alarms.Eliminates the need for any cabling between the Ei428 and the smoke heat and CO alarms used in the system.Requires 230V AC Mains Power Supply Green LED to indicate mains power is present.Features built-in tamper proof Rechargeable Vanadium Pentoxide lithium standby cells capable of lasting at least 10 years and powering the module initially for at least 2 months in the event of mains power failure. The cell manufacturer endorses a minimum 10-year life expectation for the rechargeable cells which are activated by operating the battery switch inside the module.The product is CE marked to indicate conformance to BS EN 600651998 Electrical Safety EN300220-1 V1.3.1 2000-09 RF Performance EN301489 V1.4.1 2002 08 EMC and has been 3rd party tested for electrical safety in accordance with Annex K of BS 5446 Pt.12000.Radio frequency 868 MHz Band in accordance with RTTE Directive 19995EC this band has been designated for use with security products and only allows a 1 duty cycle so continuous transmission and interference form external sources is extremely remote and would be illegal.Range The type of building will be the major limiting factor e.g. the number and type of wallsceilings that the radio signal has to pass through. As a guide 30m should be the maximum distance between any of the RadioLINK units in the system.Up to 20 RadioLINK units can be used in one system. Range will be the limiting factor.Low back-up warning signal LED indicator flashes RED every 10 seconds to indicate that the lithium cells are depleted.Units are in Factory Code mode when received they will all communicate with each other. They must be House Coded to eliminate the risk of adjacent properties communicating with each other. After House Coding they will only communicate with other RadioLINK units coded at the same time.House Code Operate the House Code switch on all RadioLINK units in the system see the instructions supplied with other RadioLINK units being used. The green LED on the cover of the Ei428 will change to red and flash slowly this indicates that it will receive the unique serial numbers being sent by all other RadioLINK units in House Code. The number of flashes of the LED indicates the number of units in the system The Ei428 will return to normal standby mode automatically after 15 minutes. Pressing the House Code switch again will return it to normal standby immediately.Volt free contacts Normally Open or Normally Closed rated up to 240V AC 5 Amps making it suitable for use with a wide range of AC or DC voltages. The relay contacts operate on mains power or on back-up cells in the event of mains failure.A RadioLINK Manual Call Point Ei407 and remote control switches Ei450 Ei412 and Ei411H are also available for use in the system. See separate specification sheets for further information.Features 1 x 25mm trunking for for surface wiring and centre knockout for recess wiring.Ambient Temperature Range 4C to 40C. Humidity Range 0 to 90 relative humidity.Dimensions 140mm diameter x 27mm depth weight inclusive of packaging 220g.5 year guarantee.Manufactured in Ireland.Key FeaturesDesigned for use with all RadioLINK Professional alarms and accessoriesRechargeable Lithium battery back-upVolt-free contacts as supplied for multiple usesCan be configured to switch a 230V or 24V outputTrunking knock-outs for easy and neat wiringContinuous or Pulse operation5 Year Guarantee GBP 98.36 1
Aico RadioLINK Alarm for Deaf 230V with Strobe Vibrating Pad Ei170RF Aico RadioLINK Alarm for Deaf 230V with Strobe Vibrating Pad Ei170RFTheEi170RF is a mains powered with rechargeable battery back up alarm kitfor the deaf and hard of hearing. Thekit contains aXenon strobe lightthat provide and plug in vibrating pillow pad that will activate when the interconnected alarms are triggered to alert theuser tothe danger.TheEi170RF kit is compatible with the3000Multi-Sensor Fire Alarm Ei2110e160e Seriesalarms and 140RC Series smoke and heat alarms along with any interconnected Carbon Monoxide alarms. This kit links into the alarm system usingRadioLINK wireless interconnection technology making it easier to add into a system and causing less disruption to the occupants on installation.An integral Test button is also present on the front of the unit allowing an easy means of testing the strobe vibration pad and the RadioLINK enabled alarms in the system.As with other RadioLINK products the Ei170 Alarm Kit for the Deaf and Hard of Hearing will need to belinked into the alarm system or House Coded. View ourstep by step guide to House Coding here.Technical Specification A strobe and vibrating pillow pad kit designed to give warning of fire to deaf and hard of hearing occupants. For use with30002110e160eand 140RC Series smoke and heat alarms when used with aRadioLINK baseRadioLINK moduleor theSmartLINKmoduleRadioLINK Carbon MonoxideCO alarms. It can also be used with all other RadioLINK devicesancillaries including the 600 Series RadioLINK smoke and heat alarms.Eliminates the need for any cabling between the Ei170 RF and the smoke heat andor CO alarms used in the system.Requires 230V AC 50Hz mains power supply.The unit has a built-in high-intensity Xenon strobe flash rate 0.8Hz with a wide light output angle.Built-in long life sealed lead acid rechargeable battery to provide back-up power in the event of mains failure. Standby capacity 7 days followed by 15 minutes alarm lifespan 5 years in normal use. The battery is connected by plugging it into the socket in the bottom of the battery box.Comprehensive indicating lights on front of the unitPower Constant green to indicate mains is present flashes amber every 4 seconds with mains absent.Alarm red Flashes every second when the unit has been triggered.Fault amber Flashes every 4 seconds if a fault is detected with panelvibration pad. Flashes every 4 seconds if rechargeable back-up battery is depleted or faulty.RF status blue Illuminates when RF signal is being sent flashes in House Code mode to indicate the number of units learned. Flashes every 40 seconds if RadioLINK smoke alarms have a low battery.Mains transformer is mounted in separate and hard-wired to the strobe unit with 4m of low voltage cable. Supplied with 2m of mains cable and pre-wired 13 amp plug with a 3 amp fuse.Integrated Test button on the front of the unit. Pressing this checks strobe and control circuitry and also send out a RadioLINK alarm signal to other units in the system.The vibrating pillow pad is suitable for mounting under mattresses or pillows and produces strong pulsed vibrations suitable for waking sleepers. Supplied with locking plug and 5m of pre-wired cable.Connecting sockets on rear of unit as followsVibration Pad socket Locking socket JST type VHR-2N. Is pulsed when unit is in alarm.Auxiliary sockets Two auxiliary sockets are available on the rear of the unit to allow connection of additional strobes etc. Locking sockets JST type VHR-2N. Each provides 12V200mA when unit is in alarm. Can be used for any of the following Auxiliary strobe Ei178 auxiliary vibration pad Ei174 or for triggering a radio pager.A clock input socket is also available. This is for use will alarm clocks that have a 3.5mm mono jack output and saves the need for multiple vibration pads. An input of 5-12V AC or DC mains isolated will turn on the vibration pad constant vibration pattern but will not activate the strobe or auxiliary sockets.Radio frequency 868MHz band in accordance with RTTE Directive 19995EC this band has been designed for use with security products and only allows a 1 duty cycle so continuous transmission and interference from external sources is extremely remote and would be illegal. Complies with EN300220-2V2.1.1.RF Range The type of building will be the major limiting factor e.g. the number and type of wallsceilings that the radio signal has to pass through. As a guide 30m should be the maximum distance between any of the RadioLINK units in the system.Up to 12 RadioLINK units can be used in one system. For larger systems contact our Technical Department for guidance. GBP 279.71 1
Aico RadioLINK Panel Interface Ei413 Aico RadioLINK Panel Interface Ei413The Ei413 is a RadioLINK Panel Interface Module that provides an interface between RadioLINK alarms and accessories and fire alarmsecurity alarm panels. The module will decode aFire Carbon Monoxide and fault signals from RadioLINK devices and activate the Panel accordingly and will also work the other way activating the domestic alarms if it receives a signal from the Panel.The module is powered either directly from the Panel Systemor from an external source.Operation of the Ei413 RadioLINK Panel Interference ModuleOn receiving a Volt-free switched hardwired signal from the panel the module will transmit a RadioLINK alarm signal to activate the alarms in the systemIf a fire alarm has activated the module will recognise the signal as a fire and switch the relevant contacts to activate the panelIf a Carbon Monoxidealarm has activated the module will recognise the signal as a Carbon Monoxideleak and switch the relevant contacts to activate the panelTechnical SpecificationEliminate the need for any cabling between the Ei413 and the smokeheatCO alarms used in the system.The Ei413 is conformant to EN300220-1 RF Performance in accordance with EN300220-2 and EN301489-1 EMC referencing EN301489-3.The unit is powered from the alarm panel and requires 11 to 30VDC. Unit current rating 15mA Standby 60mA Alarm Max.The unit has three sets Normally Open Normally Closed and Common of built-in wiring contacts for connection to the panel rated at 30V 1 Amp. On the contacts closing the unit will dependent on which set of contacts are connected indicate a fire CO leak or fault to the panel. The unit also has a Normally Open volt-free set of contacts to link from the panel to it so if the panel is activated the unit will transmit a RadioLINK signal to the alarms in the system to activate them they will sound.Radio frequency 868MHz band in accordance with RTTE Directive 19995EC this band has been designed for use with security products and only allows a 1 duty cycle so continuous transmission and interference from external sources is extremely remote and would be illegal.Up to 12 RadioLINK units can be used in one system. Range may be a limiting factor.RF Range The type of building will be the major limiting factor e.g. the number and type of wallsceilings that the radio signal has to pass through. As a guide 30m should be the maximum distance between any of the RadioLINK units in the system.Units are in factory code when received they will communicate with each other. They must be House Coded to eliminate the risk of adjacent properties communicating with each other. After House Coding they will only communicate with other RadioLINK units coded at the same time.House Code Operate the House Code Switch on all RadioLINK units in the system see the instructions supplied with the other RadioLINK units being used. The LED indicator on the front cover of the Ei413 will flash blue slowly this indicates that it is transmitting its unique serial number to all other RadioLINK units in House Code. After a short time the unit will flash to indicate the number of units in the system 2 flashes 2 units 3 flashes 3 units etc.. The Ei413 will return to normal standby mode automatically after 15 minutes. Pressing the House Code Switch again will return it to normal standby immediately.Designed for surface mounting or can be fitted into certain alarm panels provided the casing is not a metallic construction which may restrict RF signals.Dimensions 88mm x 88mm x 28mm.Weight 150g.Ambient Temperature Range 0C to 40C.5 year guarantee.Manufactured in Ireland. GBP 76.93 1
Aico RadioLINK Switched Input Module Ei408 Aico RadioLINK Switched Input Module Ei408The Ei408 Switched Input Modulehas been designed totriggers the alarmsin a system if anexternal device isactivated such as a sprinkler system.The Ei408 is powered by a tamper proof sealed in lithium cell giving a completely wire free installation with a 10 year life.The unituses RadioLINK to wirelessly interconnect with the rest of the alarm system so once in place you will need toHouse Codethe switch into the alarm system.Operation of the Ei408On receiving a volt-free switched hardwired signal the unit will transmit a RadioLINK alarm signalThe indicator will flash green every 40 seconds to indicate that the lithium cell power supply is healthyIf the Lithium cells are depleted the indicator will flash amber every 10 seconds and the unit needs replacingTechnical SpecificationFor use with 140RC when using anEi168Rc RadioLINK base160ewhen using andEi100MRF RadioLINK module Ei3000 series when using anEI3000MRF SmartLINK moduleor any RadioLINK enabled CO alarms.Eliminates the need for any cabling between the Ei408 and the smoke heat and CO alarms used in the system.Features built-in tamper proof FDK Lithium cells capable of lasting at least 10 years under normal usage. Operating the yellow onoff switch sited on the back of the unit activates the cells. The LED on the front cover will flash red amber green on power up after this it will flash green every 40 seconds to indicate a healthy power supply.Low battery warning signal LED indicator flashes amber every 10 seconds to indicate depleted battery. If this occurs the complete unit should be replaced.The unit has built-in wiring terminals for connection to an external set of volt-free switched contacts. On the contacts closing the Ei408 will send out a RadioLINK alarm signal to trigger all other RadioLINK devices within the system.Radio frequency 868 MHz Band in accordance with RTTE Directive 19995EC this band has been designated for use with security products and only allows a 1 duty cycle so continuous transmission and interference form external sources is extremely remote and would be illegal.Range The type of building will be the major limiting factor e.g. the number and type of wallsceilings that the radio signal has to pass through. As a guide 30m should be the maximum distance between any of the RadioLINK units in the system.Up to 20 RadioLINK units can be used in one system. Range will be the limiting factor.Units are in Factory Code mode when received they will all communicate with each other. They must be House Coded to eliminate the risk of adjacent properties communicating with each other. After House Coding they will only communicate with other RadioLINK units coded at the same time.House Code Operate the House Code switch on all RadioLINK units in the system see the instructions supplied with other RadioLINK units being used. The green LED on the cover of the Ei428 will change to red and flash slowly this indicates that it will receive the unique serial numbers being sent by all other RadioLINK units in House Code. The number of flashes of the LED indicates the number of units in the system The Ei428 will return to normal standby mode automatically after 15 minutes. Pressing the House Code switch again will return it to normal standby immediately.The Ei408 is conformant to EN300220-1 2000-09 RF Performance and EN301489-3 2002-08 EMC.Designed for surface mounting.Ambient Temperature Range 4C to 40C. Humidity Range 0 to 90 relative humidity.Dimensions 90mm x 90mm x 43mm. Weight inclusive of packaging 240g.5 year guarantee.Manufactured in Ireland.Key FeaturesStand alone unit designed for use with RadioLINK bases AccessoriesAccepts a hardwired input e.g. from sprinkler systemVisual RF transmission and power indicatorPowered by built-in Lithium cellsUnique House CodingLow battery power warningRF performance to EN 300220-15 Year Guarantee GBP 61.67 1
Aico RadioLINK Manual Call Point Ei407 Aico RadioLINK Manual Call Point Ei407This call point is powered by a tamper proof sealed inlithium cell giving a completely wire free installation with a 10-year life.The front plate is made from a non-breaking plastic that means if the callpoint is used you can simply reset the plate rather than having to replace it.The Ei407 connects wirelessly using RadioLINKinterconnection technology so once in place you will need to House Code theswitch into the alarm system.Operation The indicator will flash green every 40 seconds to indicatethat the battery is healthyThe indicator will flash amber every 9 seconds to indicatethat the batteries are depletedKey FeaturesAllows for remote triggering of an alarm systemNon-breaking re-settable front platesContains 10-year lithium cell for completely wire freeinstallationConnects wirelessly with all other Aico wirelessinterconnection productsTechnical SpecificationFor use with 140RC when using anEi168Rc RadioLINK base160ewhen using andEi100MRF RadioLINK module Ei3000 series when using anEI3000MRF SmartLINK moduleor any RadioLINK enabled CO alarmsEliminates the need for any cabling between the Ei407 and the smoke andor heat alarms within the systemFeatures built-in tamper proof FDK Lithium cells capable of lasting at least 10 years under normal usage. operating the yellow onoff switch sited on the back of the unit activates the cells. The LED on the front cover will flash red amber green on power up after this it will flash green every 40 seconds to indicate a healthy power supply. If the LED flashes amber every 40 seconds this indicates a depleted battery and the complete unit must be replacedThe product is CE marked to indicate conformance to BS EN 600651998 Electrical Safety EN300220-1 V1.3.1 2000-09 RF Performance EN301489 V1.4.1 2002-08 EMC and has been 3rd party tested for electrical safety in accordance with Annex K of BS 5446 Pt 12000Radio frequency 868MHz in accordance with RTTE Directive 19995EC this band has been designated for use with security products and only allows a 1 duty cycle so continuous transmission and interference from external sources is extremely remote and would be illegalUp to 12 RadioLINK units can be used in one system. For larger systems contact our Technical Department for guidance also see section 7Range the type of building will be the major limiting factor e.g. the number and type of wallsceilings that the radio signal has to pass throughLow battery warning signal LED indicator flashes amber every 40 seconds to indicate depleted battery if this occurs the complete unit should be replacedSimply key to rest the unit no broken glassReplacement key MCRSK availableAmbient temperature range 4c to 40c. Humidity range 0 to 90 relative humidityExternal alarm RadioLINK signal operates sounder on any smoke alarm with a RadioLINK in the systemUnits are in factory code when received they will all communicate with each other. They must be House Coded to eliminate the risk of adjacent properties communicating with each other. After house coding they will only communicate with other units coded at the same timeHouse Code Operate the red House Code switch on the back of the unit. At the same time put all other RadioLINK units in the system into House Code see relevant instruction leaflets. The red LED on the front cover will flash rapidly to indicate that it is in House Code. Each RF base will learn the serial numbers of all units in the system any other RadioLINK units. The number of flashes of the amber light on the RF units indicates the number of alarms in the system. All units will return to normal standby mode automatically after 15 minutes. Pressing the House Code switch again will return them to normal standby immediatelyThe Ei407 can be incorporated into a system consisting of any additional RadioLINK componentsDimensions 85mm x 85mm x 57mm deep including mounting boxWeight 240g including packaging5 year guaranteeManufactured in Ireland GBP 58.33 1