Advanced MXS-503-CP Spare 5400 Basecard With Large Chassis - No Loop Cards - Programmed Advanced MXS-503-CP Spare 5400 Basecard With Large Chassis - No Loop Cards - ProgrammedA spare 5400 Basecard with large chassis.Key FeaturesNo loop cardsProgrammed GBP 1137.94 1
Advanced MXM-505 MX-5000 Large Termination Enclosure Advanced MXM-505 MX-5000 Large Termination EnclosureMX-5000 Large Termination EnclosureThe MxPro 5range of control equipment can be supplied in various sized enclosures to accommodate the internal hardware and battery requirements of the control equipment.There are three standard variations to choose from which can be provided in various depths to meet the customers requirements.The options available are found on this page and dimensions documented to assist the installer.Key FeaturesDesigned for IP30 protectionAC terminal block and leadsInternal labellingHinge pins GBP 564.36 1
Advanced MxPro 5 MXM-509-SSB Semi-Flushing Bezel for RCT Large in Stainless Steel Brushed Advanced MxPro 5 MXM-509-SSB Semi-Flushing Bezel for RCT Large in Stainless Steel BrushedThe MxPro 4 and MxPro 5 series control panels can be supplied with a brushed or mirrored stainless-steel door along with a matching semi-flushing bezel to give a high-quality finish to any installation.A large range of doors and bezels are available ensuring that your installation meets the highest standards in both image and flexibility.By offering a large range of tailor-made metal work finishes the customer plays a major part in specifying exactly how the end product should look and feel.The high quality MxPro 5 Stainless Steel finish is grain matched to ensure both door and bezel grain patterns run in the same direction offering a consistent look to the installed end-product.Key FeaturesClean and stylishAesthetically pleasingHigh class look GBP 451.85 1
Advanced MxPro 5 MXM-503-SSM Semi-Flushing Bezel for Large Enclosure in Stainless Steel Mirrored Advanced MxPro 5 MXM-503-SSM Semi-Flushing Bezel for Large Enclosure in Stainless Steel MirroredThe MxPro 4 and MxPro 5 series control panels can be supplied with a brushed or mirrored stainless-steel door along with a matching semi-flushing bezel to give a high-quality finish to any installation.A large range of doors and bezels are available ensuring that your installation meets the highest standards in both image and flexibility.By offering a large range of tailor-made metal work finishes the customer plays a major part in specifying exactly how the end product should look and feel.The high quality MxPro 5 Stainless Steel finish is grain matched to ensure both door and bezel grain patterns run in the same direction offering a consistent look to the installed end-product.Key FeaturesClean and stylishAesthetically pleasingHigh class look GBP 575.40 1
Advanced MxPro 5 MXM-503-SSB Semi-Flushing Bezel for Large Enclosures in Stainless Steel Brushed Advanced MxPro 5 MXM-503-SSB Semi-Flushing Bezel for Large Enclosures in Stainless Steel BrushedThe MxPro 4 and MxPro 5 series control panels can be supplied with a brushed or mirrored stainless-steel door along with a matching semi-flushing bezel to give a high-quality finish to any installation.A large range of doors and bezels are available ensuring that your installation meets the highest standards in both image and flexibility.By offering a large range of tailor-made metal work finishes the customer plays a major part in specifying exactly how the end product should look and feel.The high quality MxPro 5 Stainless Steel finish is grain matched to ensure both door and bezel grain patterns run in the same direction offering a consistent look to the installed end-product.Key FeaturesClean and stylishAesthetically pleasingHigh class look GBP 511.50 1
Advanced MxPro 5 MXM-509-SSM Semi-Flushing Bezel for RCT Large in Stainless Steel Mirrored Advanced MxPro 5 MXM-509-SSM Semi-Flushing Bezel for RCT Large in Stainless Steel MirroredThe MxPro 4 and MxPro 5 series control panels can be supplied with a brushed or mirrored stainless-steel door along with a matching semi-flushing bezel to give a high-quality finish to any installation.A large range of doors and bezels are available ensuring that your installation meets the highest standards in both image and flexibility.By offering a large range of tailor-made metal work finishes the customer plays a major part in specifying exactly how the end product should look and feel.The high quality MxPro 5 Stainless Steel finish is grain matched to ensure both door and bezel grain patterns run in the same direction offering a consistent look to the installed end-product.Key FeaturesClean and stylishAesthetically pleasingHigh class look GBP 501.28 1
Advanced MXM-506 MX-5000 Large-Deep Termination Enclosure Advanced MXM-506 MX-5000 Large-Deep Termination EnclosureThe MxPro 5range of control equipment can be supplied in various sized enclosures to accommodate the internal hardware and battery requirements of the control equipment.There are three standard variations to choose from which can be provided in various depths to meet the customers requirements.The options available are found on this page and dimensions documented to assist the installer.Key Features The back-box features includeDesigned for IP30 protectionAC terminal block and leadsInternal labellingHinge pins GBP 600.18 1
Advanced MxPro5 MX-5101L 1-Loop Fire Panel in Large Enclosure Advanced MxPro5 MX-5101L 1-Loop Fire Panel in Large EnclosureThe MxPro5 series control panels are supplied with a single loop driver card 2 onboard sounder circuits 20 programmable zonal LEDs with slide-in labels and 25 system LEDs for information purposes. There are also 4 programmable function buttons with LED indication for confirmation of operation.The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple select click programming aid for engineer configuration and end user operation.Powerful cause-and-effect programming coupled with dynamic zoning and enhanced trace diagnostics makes the panel suitable for a wide range of site applications from small to large complex multi-area systems. Fully programmable on-site via the on-board alphanumeric keypad or PC-NeT Configuration Software.An extensive suite of user-friendly Windows based PC software programs has been developed to enhance your experience when using MxPro5 series fire panels. The suite incorporates a number of different programmes which include configuration service logo and virtual panel tools to allow the flexibility of the equipment to be fully explored.Simply adding a network card allows the panel to communicate with any other MxPro5 fire panel remote terminal or network peripheral such as ipGateway BMS or graphical interface. The network operates as a true peer-to-peer system and can be configured in a fault tolerant loop or radial format.Key Features20 programmable zonal 25 System LEDsApollo Argus Vega Hochiki Nittan Evolution protocol supportAdvanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardwareDedicated USB RS232 Serial Port for direct PC or modem connection.Installer friendly Auto-learn LoopDetection and On-board Scope facilityGraphical display configurable for virtually any languageRobust removable equipment chassis with plug-in connectors for simple fixing and cable terminationIntegral P-Bus for system expansion via available option cardsAd-NeT peer-to-peer network with up to 2000 zonesApproved to BS EN54 part 2 4 and 13 GBP 1166.66 1
Advanced MxPro5 MX-5101D 1-Loop Fire Panel in Large-Deep Enclosure Advanced MxPro5 MX-5101D 1-Loop Fire Panel in Large-Deep EnclosureThe MxPro5 series control panels are supplied with a single loop driver card 2 onboard sounder circuits 20 programmable zonal LEDs with slide-in labels and 25 system LEDs for information purposes. There are also 4 programmable function buttons with LED indication for confirmation of operation.The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple select click programming aid for engineer configuration and end user operation.Powerful cause-and-effect programming coupled with dynamic zoning and enhanced trace diagnostics makes the panel suitable for a wide range of site applications from small to large complex multi-area systems. Fully programmable on-site via the on-board alphanumeric keypad or PC-NeT Configuration Software.An extensive suite of user-friendly Windows based PC software programs has been developed to enhance your experience when using MxPro5 series fire panels. The suite incorporates a number of different programmes which include configuration service logo and virtual panel tools to allow the flexibility of the equipment to be fully explored.Simply adding a network card allows the panel to communicate with any other MxPro5 fire panel remote terminal or network peripheral such as ipGateway BMS or graphical interface. The network operates as a true peer-to-peer system and can be configured in a fault tolerant loop or radial format.Key Features20 programmable zonal 25 System LEDsApollo Argus Vega Hochiki Nittan Evolution protocol supportAdvanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardwareDedicated USB RS232 Serial Port for direct PC or modem connection.Installer friendly Auto-learn LoopDetection and On-board Scope facilityGraphical display configurable for virtually any languageRobust removable equipment chassis with plug-in connectors for simple fixing and cable terminationIntegral P-Bus for system expansion via available option cardsAd-NeT peer-to-peer network with up to 2000 zonesApproved to BS EN54 part 2 4 and 13 GBP 1225.43 1
Advanced MX-5101AL 1 Loop MxPro5 Fire Control Panel - Large Core Protocol Advanced MX-5101AL 1 Loop MxPro5 Fire Control Panel - Large Core ProtocolThe MxPro 5 series control panels are supplied with a single loop driver card 2 on board sounder circuits 20 programmable zonal LEDs with slide-in labels and 25 system LEDs for information purposes. There are also 4 programmable function buttons with LED indication for confirmation of operation. The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple select click programming aid for engineer configuration and end user operation.Powerful cause-and-effect programming coupled with dynamic zoning and enhanced trace diagnostics makes the panel suitable for a wide range of site applications from small to large complex multi-area systems. The panel is fully programmable on-site via the on-board alphanumeric keypad or PC-NeT Configuration Software. An extensive suite of user-friendly Windows based PC software programs has been developed to enhance your experience when using MxPro 5 series fire panels.The suite incorporates a number of different programmes which include configuration service logo and virtual panel tools to allow the flexibility of the equipment to be fully explored. Simply adding a network card allows the panel to communicate with any other MxPro 5 fire panel remote terminal or network periferal such as ipGateway BMS or graphical interface. The network operates as a true peer-to-peer system and can be configured in a fault tolerant loop or radial format.Key Features20 programmable Zonal 25 System LEDs.Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing fullEN54 compliance without additional hardware.Dedicated USB RS232 Serial Port for direct PC or modem connection.Installer friendly Auto-learn Loop Detection and On-board Scope facility.Graphical display configurable for virtually any language.Robust removable equipment chassis with plug-in connectors for simple fixing and cable termination.Integral P-Bus for system expansion via available option cards.Ad-NeT peer-to-peer network with up to 2000 zonesApproved to BS EN54 part 2 4 and 13Please note The image is for illustrative purposes only. GBP 1166.66 1
Advanced MxPro 5 MXP-513L-200RY 200 Zone Large Enclosure REDYEL Advanced MxPro 5 MXP-513L-200RY 200 Zone Large Enclosure REDYELThe LED indicator cards are a range of panel mounted peripheral modules that can be added to the MxPro 5series of control panels.The display cards are available in numerous configurations and provide individual indication of the zones in Fire by default but are also fully programmable.The units fully supports dynamic zoning on networked or larger standalone systems and can be used to provide individual zonal LED indication at one location. Applications The zoneLED indicator card can be fitted to all MxPro 5control panels to provide indication of the zones in fire in addition to the panel graphical display.The LED will illuminate when the corresponding zone enters a Fire condition. This next generation in LED technology also allows the LED to be fully programmed.Each LED can now operate in accordance with the cause-and-effect strategy in which the LED can illuminate upon Fault Isolation Output Group plus many more. LED cards can now be ordered with Red and Yellow LED arrangements or provided with bi-colour LEDs with slide-in labels to assist identifying the origin of the condition.Key FeaturesProgrammable LEDsFactory fitted or retro-fitSupports dynamic zoningFully programmableCost effective against ancillary hardware GBP 466.64 1
Advanced MxPro5 MX-5101NL 1-Loop Fire Panel in Large Enclosure Nittan Evolution Protocol Advanced MxPro5 MX-5101NL 1-Loop Fire Panel in Large Enclosure Nittan Evolution ProtocolThe MxPro5 series control panels are supplied with a single loop driver card 2 onboard sounder circuits 20 programmable zonal LEDs with slide-in labels and 25 system LEDs for information purposes. There are also 4 programmable function buttons with LED indication for confirmation of operation.The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple select click programming aid for engineer configuration and end user operation.Powerful cause-and-effect programming coupled with dynamic zoning and enhanced trace diagnostics makes the panel suitable for a wide range of site applications from small to large complex multi-area systems. Fully programmable on-site via the on-board alphanumeric keypad or PC-NeT Configuration Software.An extensive suite of user-friendly Windows based PC software programs has been developed to enhance your experience when using MxPro5 series fire panels. The suite incorporates a number of different programmes which include configuration service logo and virtual panel tools to allow the flexibility of the equipment to be fully explored.Simply adding a network card allows the panel to communicate with any other MxPro5 fire panel remote terminal or network peripheral such as ipGateway BMS or graphical interface. The network operates as a true peer-to-peer system and can be configured in a fault tolerant loop or radial format.Key Features20 programmable zonal 25 System LEDsApollo Argus Vega Hochiki Nittan Evolution protocol supportAdvanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardwareDedicated USB RS232 Serial Port for direct PC or modem connection.Installer friendly Auto-learn LoopDetection and On-board Scope facilityGraphical display configurable for virtually any languageRobust removable equipment chassis with plug-in connectors for simple fixing and cable terminationIntegral P-Bus for system expansion via available option cardsAd-NeT peer-to-peer network with up to 2000 zonesApproved to BS EN54 part 2 4 and 13 GBP 1166.66 1
Advanced MxPro5 MX-5101ND 1-Loop Fire Panel in Large-Deep Enclosure Nittan Evolution Protocol Advanced MxPro5 MX-5101ND 1-Loop Fire Panel in Large-Deep Enclosure Nittan Evolution ProtocolThe MxPro5 series control panels are supplied with a single loop driver card 2 onboard sounder circuits 20 programmable zonal LEDs with slide-in labels and 25 system LEDs for information purposes. There are also 4 programmable function buttons with LED indication for confirmation of operation.The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple select click programming aid for engineer configuration and end user operation.Powerful cause-and-effect programming coupled with dynamic zoning and enhanced trace diagnostics makes the panel suitable for a wide range of site applications from small to large complex multi-area systems. Fully programmable on-site via the on-board alphanumeric keypad or PC-NeT Configuration Software.An extensive suite of user-friendly Windows based PC software programs has been developed to enhance your experience when using MxPro5 series fire panels. The suite incorporates a number of different programmes which include configuration service logo and virtual panel tools to allow the flexibility of the equipment to be fully explored.Simply adding a network card allows the panel to communicate with any other MxPro5 fire panel remote terminal or network peripheral such as ipGateway BMS or graphical interface. The network operates as a true peer-to-peer system and can be configured in a fault tolerant loop or radial format.Key Features20 programmable zonal 25 System LEDsApollo Argus Vega Hochiki Nittan Evolution protocol supportAdvanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardwareDedicated USB RS232 Serial Port for direct PC or modem connection.Installer friendly Auto-learn LoopDetection and On-board Scope facilityGraphical display configurable for virtually any languageRobust removable equipment chassis with plug-in connectors for simple fixing and cable terminationIntegral P-Bus for system expansion via available option cardsAd-NeT peer-to-peer network with up to 2000 zonesApproved to BS EN54 part 2 4 and 13 GBP 1225.43 1
Advanced MxPro 5 MXP-513L-200RYF 200 Zone Large Enclosure REDYEL Fitted Advanced MxPro 5 MXP-513L-200RYF 200 Zone Large Enclosure REDYEL FittedThe LED indicator cards are a range of panel mounted peripheral modules that can be added to the MxPro 5series of control panels.The display cards are available in numerous configurations and provide individual indication of the zones in Fire by default but are also fully programmable.The units fully supports dynamic zoning on networked or larger standalone systems and can be used to provide individual zonal LED indication at one location. Applications The zoneLED indicator card can be fitted to all MxPro 5control panels to provide indication of the zones in fire in addition to the panel graphical display.The LED will illuminate when the corresponding zone enters a Fire condition. This next generation in LED technology also allows the LED to be fully programmed.Each LED can now operate in accordance with the cause-and-effect strategy in which the LED can illuminate upon Fault Isolation Output Group plus many more. LED cards can now be ordered with Red and Yellow LED arrangements or provided with bi-colour LEDs with slide-in labels to assist identifying the origin of the condition.Key FeaturesProgrammable LEDsFactory fitted or retro-fitSupports dynamic zoningFully programmableCost effective against ancillary hardwareFitted GBP 466.64 1
Advanced MxPro5 MX-5101VL 1 Loop Fire Panel in Large Enclosure Argus Vega Protocol Advanced MX-5101VL 1 Loop Fire Panel in Large Enclosure Argus Vega ProtocolThe MxPro5 series control panels are supplied with a single loop driver card 2 on board sounder circuits 20 programmable zonal LEDs with slide-in labels and 25 system LEDs for information purposes. There are also 4 programmable function buttons with LED indication for confirmation of operation. The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple select click programming aid for engineer configuration and end user operation.Powerful cause-and-effect programming coupled with dynamic zoning and enhanced trace diagnostics makes the panel suitable for a wide range of site applications from small to large complex multi-area systems. The panel is fully programmable on-site via the on-board alphanumeric keypad or PC-NeT Configuration Software. An extensive suite of user-friendly Windows based PC software programs has been developed to enhance your experience when using MxPro 5 series fire panels.The suite incorporates a number of different programmes which include configuration service logo and virtual panel tools to allow the flexibility of the equipment to be fully explored. Simply adding a network card allows the panel to communicate with any other MxPro 5 fire panel remote terminal or network periferal such as ipGateway BMS or graphical interface. The network operates as a true peer-to-peer system and can be configured in a fault tolerant loop or radial format.Key Features20 programmable zonal 25 System LEDs.Apollo Argus Vega Hochiki Nittan Evolution protocol support.Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing fullEN54 compliance without additional hardware.Dedicated USB RS232 Serial Port for direct PC or modem connection.Installer friendly Auto-learn Loop Detection and On-board Scope facility.Graphical display configurable for virtually any language.Robust removable equipment chassis with plug-in connectors for simple fixing and cable termination.Integral P-Bus for system expansion via available option cards.Ad-NeT peer-to-peer network with up to 2000 zonesApproved to BS EN54 part 2 4 and 13 GBP 1166.66 1
Advanced MxPro 5 MX-5030 Remote Control Terminal Standard Network with Large Enclosure Advanced MxPro 5 MX-5030 Remote Control Terminal Standard Network with Large EnclosureThe remote terminals utilise the same graphical LCD user interface that can be found on the MxPro 5 series fire panels and are based upon the same advanced flash based microprocessor technology. The MxPro 5 panels and remote terminals can communicate over the same 2-core network cable. They feature an integral network interface incorporating a special screen termination to prevent mains frequency earth-loop currents flowing between network nodes.The Ad-NeT network operates as a true peer-to-peer system with full cross panel reporting control and cause-and-effect functionality of up to 2000 zones. All remote terminals incorporate buzzer mute view enabledisable and test facilities with dedicated system and navigation keys for simple user control. The display information is fully programmable by individual zone or sector and can display any combination of fires faults pre-alarms or plant alarms. E.g. can display all information in its own sector but can only show fire signals from other sectors of a building.Key FeaturesProgrammable switch inputGraphical LCD DisplayAd-NeTAd-NeT CompatibleSlide-in LabelsSmall robust compact24V DC Operating voltage3 Year WarrantyDisableenable options GBP 961.03 1
Advanced MxPro5 MX-5101VD 1 Loop Fire Panel in Large-Deep Enclosure Argus Vega Protocol Advanced MxPro5 MX-5101VD 1 Loop Fire Panel in Large-Deep Enclosure Argus Vega ProtocolThe MxPro5 series control panels are supplied with a single loop driver card 2 on board sounder circuits 20 programmable zonal LEDs with slide-in labels and 25 system LEDs for information purposes. There are also 4 programmable function buttons with LED indication for confirmation of operation. The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple select click programming aid for engineer configuration and end user operation.Powerful cause-and-effect programming coupled with dynamic zoning and enhanced trace diagnostics makes the panel suitable for a wide range of site applications from small to large complex multi-area systems. The panel is fully programmable on-site via the on-board alphanumeric keypad or PC-NeT Configuration Software. An extensive suite of user-friendly Windows based PC software programs has been developed to enhance your experience when using MxPro 5 series fire panels.The suite incorporates a number of different programmes which include configuration service logo and virtual panel tools to allow the flexibility of the equipment to be fully explored. Simply adding a network card allows the panel to communicate with any other MxPro 5 fire panel remote terminal or network periferal such as ipGateway BMS or graphical interface. The network operates as a true peer-to-peer system and can be configured in a fault tolerant loop or radial format.Key Features20 programmable zonal 25 System LEDs.Apollo Argus Vega Hochiki Nittan Evolution protocol support.Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing fullEN54 compliance without additional hardware.Dedicated USB RS232 Serial Port for direct PC or modem connection.Installer friendly Auto-learn Loop Detection and On-board Scope facility.Graphical display configurable for virtually any language.Robust removable equipment chassis with plug-in connectors for simple fixing and cable termination.Integral P-Bus for system expansion via available option cards.Ad-NeT peer-to-peer network with up to 2000 zonesApproved to BS EN54 part 2 4 and 13 GBP 1225.43 1
Advanced MxPro 5 MX-5030FT Remote Control Terminal Fault Tolerant Network with Large Enclosure Advanced MxPro 5 MX-5030FT Remote Control Terminal Fault Tolerant Network with Large EnclosureThe remote terminals utilise the same graphical LCD user interface that can be found on the MxPro 5 series fire panels and are based upon the same advanced flash based microprocessor technology. The MxPro 5 panels and remote terminals can communicate over the same 2-core network cable. They feature an integral network interface incorporating a special screen termination to prevent mains frequency earth-loop currents flowing between network nodes.The Ad-NeT network operates as a true peer-to-peer system with full cross panel reporting control and cause-and-effect functionality of up to 2000 zones. All remote terminals incorporate buzzer mute view enabledisable and test facilities with dedicated system and navigation keys for simple user control. The display information is fully programmable by individual zone or sector and can display any combination of fires faults pre-alarms or plant alarms. E.g. can display all information in its own sector but can only show fire signals from other sectors of a building.Key FeaturesProgrammable switch inputGraphical LCD DisplayAd-NeTAd-NeT CompatibleSlide-in LabelsSmall robust compact24V DC Operating voltage3 Year WarrantyDisableenable options GBP 1521.97 1
Advanced MxPro5 MX-5202L 1-2 Loop Fire Panel cw 2 Loop Cards in Large Enclosure Advanced MxPro5 MX-5202L 1-2 Loop Fire Panel cw 2 Loop Cardsin Large EnclosureThe MxPro5 series control panels are fully expandable from 1 - 2 loops and supplied with 2 on-board sounder circuits 20 programmable zonal LEDs with slide-in labels and 25 system LEDs for information purposes. There are also 4 programmable function buttons with LED indication for confirmation of operation.The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple select and click programming aid for engineer configuration and end user operation.Powerful cause-and-effect programming and enhanced trace diagnostics makes the panel suitable for a wide range of site applications from small to large complex multi-area systems. Fully programmable onsite via the on-board alphanumeric keypad or PC-NeT configuration software.PC Software An extensive suite of user-friendly Windows based PC software programs has been developed to enhance your experience when using MxPro5 Series of Fire panels. The suite incorporates a number of different programmes to include a configuration service logo and virtual panel tool to allow the flexibility of the equipment to be fully explored.Network Simply adding a network card allows the panel to communicate with any other MxPro5MxPro4 fire panel remote terminal or network peripheral such as ipGateway or BMSGraphical Interface.The network operates as a true peer-to-peer system and can be configured in a fault-tolerant loop or radial format.Key Features Apollo Argus Vega Hochiki Nittan Evolution protocol supportAdvanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardwareDual flash-based microprocessor technology with real-time clock on-boardDedicated USB RS232 serial port for direct PC or modem connectionInstaller friendly Auto-learn Loop Detection and On-board Scope facilities for ease of commissioning and fault findingGraphical display configurable for virtually any languageRobust removable equipment chassis with plug-in connectors for simple fixing and cable terminationFully programmable via the on-board alphanumeric keypad or PC configuration tools.Integral P-Bus for system expansion via available option cards Ad-NeT peer-to-peer network with up to 2000 zonesApproved to BS EN54 part 2 4 and 13 GBP 1600.34 1
Advanced MxPro5 MX-5201L 1-2 Loop Fire Panel cw 1 Loop Card in Large Enclosure Advanced MxPro5 MX-5201L 1-2 Loop Fire Panel comes with 1 Loop Card in Large EnclosureThe MxPro5 series control panels are fully expandable from 1 - 2 loops and supplied with 2 on-board sounder circuits 20 programmable zonal LEDs with slide-in labels and 25 system LEDs for information purposes. There are also 4 programmable function buttons with LED indication for confirmation of operation.The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple select and click programming aid for engineer configuration and end user operation.Powerful cause-and-effect programming and enhanced trace diagnostics makes the panel suitable for a wide range of site applications from small to large complex multi-area systems. Fully programmable onsite via the on-board alphanumeric keypad or PC-NeT configuration software.PC Software An extensive suite of user-friendly Windows based PC software programs has been developed to enhance your experience when using MxPro5 Series of Fire panels. The suite incorporates a number of different programmes to include a configuration service logo and virtual panel tool to allow the flexibility of the equipment to be fully explored.Network Simply adding a network card allows the panel to communicate with any other MxPro5MxPro4 fire panel remote terminal or network peripheral such as ipGateway or BMSGraphical Interface.The network operates as a true peer-to-peer system and can be configured in a fault-tolerant loop or radial format.Key Features Apollo Argus Vega Hochiki Nittan Evolution protocol supportAdvanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardwareDual flash-based microprocessor technology with real-time clock on-boardDedicated USB RS232 serial port for direct PC or modem connectionInstaller friendly Auto-learn Loop Detection and On-board Scope facilities for ease of commissioning and fault findingGraphical display configurable for virtually any languageRobust removable equipment chassis with plug-in connectors for simple fixing and cable terminationFully programmable via the on-board alphanumeric keypad or PC configuration tools.Integral P-Bus for system expansion via available option cards Ad-NeT peer-to-peer network with up to 2000 zonesApproved to BS EN54 part 2 4 and 13 GBP 1408.67 1
Advanced MX-5401A 1-4 Loop MxPro5 Fire Control Panel With 1 Loop Card - Large Core Protocol Advanced MX-5401A 1-4 Loop MxPro5 Fire Control Panel With 1 Loop Card - Large Core ProtocolThe MxPro 5 series control panels are supplied with a single loop driver card 2 on board sounder circuits 20 programmable zonal LEDs with slide-in labels and 25 system LEDs for information purposes. There are also 4 programmable function buttons with LED indication for confirmation of operation. The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple select click programming aid for engineer configuration and end user operation.Powerful cause-and-effect programming coupled with dynamic zoning and enhanced trace diagnostics makes the panel suitable for a wide range of site applications from small to large complex multi-area systems. The panel is fully programmable on-site via the on-board alphanumeric keypad or PC-NeT Configuration Software. An extensive suite of user-friendly Windows based PC software programs has been developed to enhance your experience when using MxPro 5 series fire panels.The suite incorporates a number of different programmes which include configuration service logo and virtual panel tools to allow the flexibility of the equipment to be fully explored. Simply adding a network card allows the panel to communicate with any other MxPro 5 fire panel remote terminal or network periferal such as ipGateway BMS or graphical interface. The network operates as a true peer-to-peer system and can be configured in a fault tolerant loop or radial format.Key Features20 programmable Zonal 25 System LEDs.Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing fullEN54 compliance without additional hardware.Dedicated USB RS232 Serial Port for direct PC or modem connection.Installer friendly Auto-learn Loop Detection and On-board Scope facility.Graphical display configurable for virtually any language.Robust removable equipment chassis with plug-in connectors for simple fixing and cable termination.Integral P-Bus for system expansion via available option cards.Ad-NeT peer-to-peer network with up to 2000 zonesApproved to BS EN54 part 2 4 and 13Please note The image is for illustrative purposes only. GBP 1903.88 1
Advanced MxPro5 MX-5201VD 1-2 Loop Fire Panel cw 1 Loop Card in Large-Deep Enclosure Advanced MxPro5 MX-5201VD 1-2 Loop Fire Panel comes with 1 Loop Card in Large-Deep EnclosureThe MxPro5 series control panels are fully expandable from 1 - 2 loops and supplied with 2 on-board sounder circuits 20 programmable zonal LEDs with slide-in labels and 25 system LEDs for information purposes. There are also 4 programmable function buttons with LED indication for confirmation of operation.The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple select and click programming aid for engineer configuration and end user operation.Powerful cause-and-effect programming and enhanced trace diagnostics makes the panel suitable for a wide range of site applications from small to large complex multi-area systems. Fully programmable onsite via the on-board alphanumeric keypad or PC-NeT configuration software.PC Software An extensive suite of user-friendly Windows based PC software programs has been developed to enhance your experience when using MxPro5 Series of Fire panels. The suite incorporates a number of different programmes to include a configuration service logo and virtual panel tool to allow the flexibility of the equipment to be fully explored.Network Simply adding a network card allows the panel to communicate with any other MxPro 5MxPro 4 fire panel remote terminal or network peripheral such as ipGateway or BMSGraphical Interface. The network operates as a true peer-topeer system and can be configured in a fault-tolerant loop or radial format.Key FeaturesApollo Argus Vega Hochiki Nittan Evolution protocol support.Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardware.Dual flash-based microprocessor technology with real-time clock on-board.Dedicated USB RS232 serial port for direct PC or modem connection.Installer friendly Auto-learn Loop Detection and On-board Scope facilities for ease of commissioning and fault finding.Graphical display configurable for virtually any languageRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination.Fully programmable via the on-board alphanumeric keypad or PC configuration tools.Integral P-Bus for system expansion via available option cardsAd-NeT peer-to-peer network with up to 2000 zonesApproved to BS EN54 part 2 4 and 13 GBP 1467.46 1
Advanced MX-5402A 1-4 Loop MxPro5 Fire Control Panel With 2 Loop Cards - Large Core Protocol Advanced MX-5402A 1-4 Loop MxPro5 Fire Control Panel With 2 Loop Cards - Large Core ProtocolThe MxPro 5 series control panels are supplied with a single loop driver card 2 on board sounder circuits 20 programmable zonal LEDs with slide-in labels and 25 system LEDs for information purposes. There are also 4 programmable function buttons with LED indication for confirmation of operation. The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple select click programming aid for engineer configuration and end user operation.Powerful cause-and-effect programming coupled with dynamic zoning and enhanced trace diagnostics makes the panel suitable for a wide range of site applications from small to large complex multi-area systems. The panel is fully programmable on-site via the on-board alphanumeric keypad or PC-NeT Configuration Software. An extensive suite of user-friendly Windows based PC software programs has been developed to enhance your experience when using MxPro 5 series fire panels.The suite incorporates a number of different programmes which include configuration service logo and virtual panel tools to allow the flexibility of the equipment to be fully explored. Simply adding a network card allows the panel to communicate with any other MxPro 5 fire panel remote terminal or network periferal such as ipGateway BMS or graphical interface. The network operates as a true peer-to-peer system and can be configured in a fault tolerant loop or radial format.Key Features20 programmable Zonal 25 System LEDs.Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing fullEN54 compliance without additional hardware.Dedicated USB RS232 Serial Port for direct PC or modem connection.Installer friendly Auto-learn Loop Detection and On-board Scope facility.Graphical display configurable for virtually any language.Robust removable equipment chassis with plug-in connectors for simple fixing and cable termination.Integral P-Bus for system expansion via available option cards.Ad-NeT peer-to-peer network with up to 2000 zonesApproved to BS EN54 part 2 4 and 13Please note The image is for illustrative purposes only. GBP 2095.55 1
Advanced MX-5403A 1-4 Loop MxPro5 Fire Control Panel With 3 Loop Cards - Large Core Protocol Advanced MX-5403A 1-4 Loop MxPro5 Fire Control Panel With 3 Loop Cards - Large Core ProtocolThe MxPro 5 series control panels are supplied with a single loop driver card 2 on board sounder circuits 20 programmable zonal LEDs with slide-in labels and 25 system LEDs for information purposes. There are also 4 programmable function buttons with LED indication for confirmation of operation. The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple select click programming aid for engineer configuration and end user operation.Powerful cause-and-effect programming coupled with dynamic zoning and enhanced trace diagnostics makes the panel suitable for a wide range of site applications from small to large complex multi-area systems. The panel is fully programmable on-site via the on-board alphanumeric keypad or PC-NeT Configuration Software. An extensive suite of user-friendly Windows based PC software programs has been developed to enhance your experience when using MxPro 5 series fire panels.The suite incorporates a number of different programmes which include configuration service logo and virtual panel tools to allow the flexibility of the equipment to be fully explored. Simply adding a network card allows the panel to communicate with any other MxPro 5 fire panel remote terminal or network periferal such as ipGateway BMS or graphical interface. The network operates as a true peer-to-peer system and can be configured in a fault tolerant loop or radial format.Key Features20 programmable Zonal 25 System LEDs.Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing fullEN54 compliance without additional hardware.Dedicated USB RS232 Serial Port for direct PC or modem connection.Installer friendly Auto-learn Loop Detection and On-board Scope facility.Graphical display configurable for virtually any language.Robust removable equipment chassis with plug-in connectors for simple fixing and cable termination.Integral P-Bus for system expansion via available option cards.Ad-NeT peer-to-peer network with up to 2000 zonesApproved to BS EN54 part 2 4 and 13Please note The image is for illustrative purposes only. GBP 2287.19 1
Advanced MX-5201AL 1-2 Loop MxPro5 Fire Control Panel With 1 Loop Card - Large Core Protocol Advanced MX-5201AL 1-2 Loop MxPro5 Fire Control Panel With 1 Loop Card - Large Core ProtocolThe MxPro 5 series control panels are supplied with a single loop driver card 2 on board sounder circuits 20 programmable zonal LEDs with slide-in labels and 25 system LEDs for information purposes. There are also 4 programmable function buttons with LED indication for confirmation of operation. The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple select click programming aid for engineer configuration and end user operation.Powerful cause-and-effect programming coupled with dynamic zoning and enhanced trace diagnostics makes the panel suitable for a wide range of site applications from small to large complex multi-area systems. The panel is fully programmable on-site via the on-board alphanumeric keypad or PC-NeT Configuration Software. An extensive suite of user-friendly Windows based PC software programs has been developed to enhance your experience when using MxPro 5 series fire panels.The suite incorporates a number of different programmes which include configuration service logo and virtual panel tools to allow the flexibility of the equipment to be fully explored. Simply adding a network card allows the panel to communicate with any other MxPro 5 fire panel remote terminal or network periferal such as ipGateway BMS or graphical interface. The network operates as a true peer-to-peer system and can be configured in a fault tolerant loop or radial format.Key Features20 programmable Zonal 25 System LEDs.Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing fullEN54 compliance without additional hardware.Dedicated USB RS232 Serial Port for direct PC or modem connection.Installer friendly Auto-learn Loop Detection and On-board Scope facility.Graphical display configurable for virtually any language.Robust removable equipment chassis with plug-in connectors for simple fixing and cable termination.Integral P-Bus for system expansion via available option cards.Ad-NeT peer-to-peer network with up to 2000 zonesApproved to BS EN54 part 2 4 and 13Please note The image is for illustrative purposes only. GBP 1408.67 1