BMS Graphics Interface with Standard Network Interface Boxed - MXP-510-BX BMS Graphics Interface with StandardNetwork Interface Boxed- MXP-510-BXThe Mxp-010 interface allows BMS systems and Graphical PCs to be integrated with the Mx-4000 series of Fire Control Panels and Remote Terminals. The interface is an integral part of the Ad- Net network permitting the handling of all network traffic and event prioritisation via a PC using a simple RS232 connection. Multiple interfaces can be connected to the network catering for sites requiring control from a number of Graphical PCs.Key FeaturesStandard FT Network versions24v DC SupplyEasily configured via PC-NET-0033 Year Warranty as standard GBP 643.27 1
Advanced MXP-510 BMS Graphics Interface Card Only Advanced MXP-510 BMS Graphics Interface Card OnlyThe BMSGraphics Interface allows BMS systems and graphical control PCs to be integrated with the MxPro 5 series of fire control panels and remote terminals.The interface is an integral part of the Ad- Net network permitting the handling of all network traffic and event prioritisation via a PC using a simple RS232 connection.Multiple interfaces can be connected to the network catering for sites requiring control from a number of graphical PCs.ApplicationsProvides connection to various 3rd party graphics systems With protocol translatorKey Features Sector based programmingEach BMS interface is individually programmable with the available dynamic cause and effects rulesStandard fault tolerant network versionsEasily configured via PC-NET-0033 year warranty as standard GBP 506.44 1
Advanced 24-LLED31INT Spare 31W Led-Lite Interface Unit Advanced 24-LLED31INT Spare 31W Led-Lite Interface UnitThe Advanced24-LLED31INT is a spare 31W Led-Lite Interface unit GBP 85.98 1
Advanced 24-LLED3INT Spare 3W Led-Lite Interface Unit Advanced 24-LLED3INT Spare 3W Led-Lite Interface UnitThe Advanced 24-LLED3INT is a spare 3W Led-Lite Interface unit. GBP 85.98 1
Advanced Damper Interface Card - MXP-046 Advanced Damper Interface Card - MXP-046The Advanced Damper Interface is a loop driver device that utilises the Apollo protocol. The device is a fully monitored interface providing confirmation of the damper open and closed positions.For use with dampers that are normally held open. Fail-safe operation only applicable to electrically opened mechanically closed dampers.Key FeaturesDamper motor drive and limit switch monitoring integrated into a single unitDual limit switch inputs for confirmation of damper-fully-open and damper-fully-closed positionsSelectable monitoring on switch inputs to prevent short circuits in the wiring from giving false position readingsFail-safe options in case of data errors in the communications loop GBP 440.33 1
Advanced 24-M083PL600 SPARE Fibre Interface Board for PLED Products Advanced 24-M083PL600 SPARE Fibre Interface Board for PLED ProductsThe Advanced 24-M083PL600 which is a spare fibre interface board for PLED products GBP 81.04 1
Advanced MXP-510FT BMS GRAPHICS Interface Card Only Fault Tolerant Advanced MXP-510FT BMS GRAPHICS Interface Card Only Fault TolerantThe BMSGraphics Interface allows BMS systems and graphical control PCs to be integrated with the MxPro 5 series of fire control panels and remote terminals.The interface is an integral part of the AdNet network permitting the handling of all network traffic and event prioritisation via a PC using a simple RS232 connection.Multiple interfaces can be connected to the network catering for sites requiring control from a number of graphical PCs.ApplicationsProvides connection to various 3rd party graphics systems with protocol translatorCompatibility Can be used with any Ad-NeT or Ad-NeT network series control panels.Key Features Sector based programmingEach BMS interface is individually programmable with the available dynamic cause and effects rulesStandard fault tolerant network versionsEasily configured via PC-NET-0033-year warranty as standard GBP 1116.26 1
Advanced MXP-510-BXFT BMS GRAPHICS Interface Boxed Fault Tolerant Advanced MXP-510-BXFT BMS GRAPHICS Interface Boxed Fault TolerantThe BMSGraphics Interface allows BMS systems and graphical control PCs to be integrated with the MxPro 5 series of fire control panels and remote terminals.The interface is an integral part of the AdNet network permitting the handling of all network traffic and event prioritisation via a PC using a simple RS232 connection.Multiple interfaces can be connected to the network catering for sites requiring control from a number of graphical PCs.ApplicationsProvides connection to various 3rd party graphics systems with protocol translatorCompatibility Can be used with any Ad-NeT or Ad-NeT network series control panels.Key Features Sector based programmingEach BMS interface is individually programmable with the available dynamic cause and effects rulesStandard fault tolerant network versionsEasily configured via PC-NET-0033-year warranty as standardPlease note The image is for illustrative purposes only. Image shows LAN PCB Board which does not come with the product. GBP 1254.68 1
Advanced 24-M08325-42V SPARE Fibre Interface Board for General Panel LEDs Advanced 24-M08325-42V SPARE Fibre Interface Board for General Panel LEDsThe Advanced 24-M08325-42V is a spare fibre interface board for general panel LEDs Driver voltages from 25V to 42V GBP 81.04 1
Advanced MxPro 4 MX-4020 Remote Control Terminal with Standard Network Interface Advanced MxPro 4 MX-4020 Remote Control Terminal with Standard Network InterfaceBased around two core products the MxPro 4 Remote Display Terminal RDT and the fully functional MxPro 4 Remote Control Terminal RCT both utilise the same graphical LCD user interface that can be found on the MxPro 4 series fire panels and are based upon the same advanced flash based microprocessor technology.All MxPro 4 series panels and remote terminals can communicate over the same 2-core network cable. Integral network interface incorporating a special screen termination to prevent mains frequency earth-loop currents flowing between network nodes. The Ad-NeT network operates as a true peer-to-peer system with full cross panel reporting control and cause and effect functionality of up to 1000 zones.Key FeaturesNetworked for System DisplayNetworked for System Control24V DC Operating Voltage3 Year warrantyGraphical LCD DisplayAd-NeTAd-NeT CompatibleSmall Robust GBP 934.91 1
Advanced MxPro 4 MX-4010 Remote Display Terminal with Standard Network Interface Advanced MxPro 4 MX-4010 Remote Display Terminal with Standard Network InterfaceBased around two core products the MxPro 4 Remote Display Terminal RDT and the fully functional MxPro 4 Remote Control Terminal RCT both utilise the same graphical LCD user interface that can be found on the MxPro 4 series fire panels and are based upon the same advanced flash based microprocessor technology.All MxPro 4 series panels and remote terminals can communicate over the same 2-core network cable. Integral network interface incorporating a special screen termination to prevent mains frequency earth-loop currents flowing between network nodes. The Ad-NeT network operates as a true peer-to-peer system with full cross panel reporting control and cause and effect functionality of up to 1000 zones.Key FeaturesNetworked for System DisplayNetworked for System Control24V DC Operating Voltage3 Year warrantyGraphical LCD DisplayAd-NeTAd-NeT CompatibleSmall Robust GBP 746.17 1
Advanced MXS-028 Spare Peripheral Fault Tolerant Network Interface Advanced MXS-028 Spare Peripheral Fault Tolerant Network InterfaceThe MXS-028 is a spare or replacement Peripheral Fault Tolerant Network Interface. GBP 741.12 1
Advanced 24-M08313W Spare Fibre Interface Board for LED-Lite Single 3W LED Luminaire Advanced 24-M08313W SPARE Fibre Interface Board for LED-Lite Single 3W LED LuminaireThe Advanced 24-M08313W which is a spare fibre interface board for LED-Lite single 3W LED luminaire GBP 81.04 1
Advanced MxPro 4 MX-4020FT Remote Control Terminal with Fault Tolerant Network Interface Advanced MxPro 4 MX-4020FT Remote Control Terminal with Fault Tolerant Network InterfaceBased around two core products the MxPro 4 Remote Display Terminal RDT and the fully functional MxPro 4 Remote Control Terminal RCT both utilise the same graphical LCD user interface that can be found on the MxPro 4 series fire panels and are based upon the same advanced flash based microprocessor technology.All MxPro 4 series panels and remote terminals can communicate over the same 2-core network cable. Integral network interface incorporating a special screen termination to prevent mains frequency earth-loop currents flowing between network nodes. The Ad-NeT network operates as a true peer-to-peer system with full cross panel reporting control and cause and effect functionality of up to 1000 zones.Key FeaturesNetworked for System DisplayNetworked for System Control24V DC Operating Voltage3 Year warrantyGraphical LCD DisplayAd-NeTAd-NeT CompatibleSmall Robust GBP 1644.04 1
Advanced MxPro 4 MX-4010FT Remote Display Terminal with Fault Tolerant Network Interface Advanced MxPro 4 MX-4010FT Remote Display Terminal with Fault Tolerant Network InterfaceBased around two core products the MxPro 4 Remote Display Terminal RDT and the fully functional MxPro 4 Remote Control Terminal RCT both utilise the same graphical LCD user interface that can be found on the MxPro 4 series fire panels and are based upon the same advanced flash based microprocessor technology.All MxPro 4 series panels and remote terminals can communicate over the same 2-core network cable. Integral network interface incorporating a special screen termination to prevent mains frequency earth-loop currents flowing between network nodes. The Ad-NeT network operates as a true peer-to-peer system with full cross panel reporting control and cause and effect functionality of up to 1000 zones.Key FeaturesNetworked for System DisplayNetworked for System Control24V DC Operating Voltage3 Year warrantyGraphical LCD DisplayAd-NeTAd-NeT CompatibleSmall Robust GBP 1455.28 1
Advanced MxPro5 MXP-046-BX1 Damper Interface Module - Boxed Apollo Protocol Advanced MxPro5 MXP-046-BX1 Damper Interface Module - Boxed Apollo ProtocolThe Advanced Damper Interface is a loop driven device that utilises the Apollo protocol. The device is a fully monitored interface providing confirmation of the damper open and closed positions.For use with dampers that are normally held open. Fail-safe operation only applicable to electrically opened mechanically closed dampers.Key FeaturesDamper motor drive and limit switch monitoring integrated into a single unitDual limit switch inputs for confirmation of damper-fully-open and damper-fully-closed positionsSelectable monitoring on switch inputs to prevent short circuits in the wiring from giving false position readingsFail-safe options in case of data errors in the communications loop GBP 616.15 1
Advanced 24-M08331W SPARE Fibre Interface Board for LED-Lite Three By 1W LED Luminaire Advanced24-M08331W SPARE Fibre Interface Board for LED-Lite Three By 1W LED LuminaireThe Advanced 24-M08331W is a fibre Interface Board for LED-Lite Three By 1W LED Luminaire GBP 81.04 1
Advanced AXIS-WSM Intelligent Sounder Interface Module Advanced AXIS-WSM Intelligent Sounder Interface ModuleThe Intelligent Sounder Interface Module is designed to allow the use of the Axis-CWS conventional sounder and Axis-CWSV conventional sounder beacon on an EvacGo intelligent loop.The Axis-WSM module is compatible with intelligent control panels and systems using Axis EN protocol. Easy to install it incorporates built-in short circuit loop isolation.Once installed onto an EvacGo intelligent loop the device is fully addressable and benefits from an extensive range of intelligent control and monitoring functionality.Key FeaturesFlexible modular designEasy to installManual and auto addressing optionsBuilt-in short circuit isolatorsUp to 32 tones as standardOptional microphone self-test facilityAddressing using the device programming tool or auto addressing capability via the fire control panelFits EvacGo modular wall sounders and sounder beacons GBP 40.80 1
Advanced Modem Interface - MXP-028 Advanced Modem Interface - MXP-028The Advanced MXP-028 Modem Card is a peripheral interface for use with the Mx40005000 range of control panels. The unit permits remote PC connection for interactive control panel interrogation via the software package PC-Net-004. The unit can be supplied in PCB format for internal panel mounting or in an enclosure for remote mounting.This unit has the following diagnosticsHeartbeat LED IndicatorDuring initial power up LED 3 will flash at a rate of 2Hz. After approximately 5 seconds it will revert to 1Hz indicating normal operation.Modem Status LEDsDCDIND Telephone connection establishedRXIND Receipt of data by modemDTRIND Always illuminatedTXIND Data transmission by modemRS232 Activity LEDsRX Receipt of data from fire panelTX - Transmission of data to fire panelApplications LimitationsThe modem will allow interactive interrogation of the connected fireproduct including transfer of the event log using Pc-Net-004 software.Key FeaturesRemote Dial-Up access to the Mx4000 series.Can be internally mounted or remotely fitted.Uses Pc-Net-004 for PC to site connection3 Year Warranty as standard. GBP 471.62 1
Advanced MxPro5 MXP-547-BX ESPA Pager Interface Boxed Advanced MxPro5 MXP-547-BX ESPA Pager Interface BoxedThe Pager Interface is a programmable interface providing connectivity of third party paging systems to the MxPro 5 control equipment. It utilises the industry standard protocol ESPA 4.4.4 and connects to the equipment via a serial data connection. An optional input function is available to monitor pager fault conditions. Specific event types e.g. Fire Alarm Pre- Alarm Fault etc. can be sent to individual pagers andor to groups of pagers.Applications LimitationsFor use with pager systems compliant to ESPA 4.4.4 protocol. If a printer is also required fit an internal printer assembly.Key FeaturesUp to 8 configurable shifts per weekdayweekendUp to 50 pager groupsUp to 250 pager addressesEach pager address can be configured to cover 2 zone rangesZone andor point information can be sent to the pagerUser defined texts are available and the basic event type text can be configuredESPA 4.4.4 protocolPanel mounted or boxed versionEasily configured via pager PC Software3 year warranty as standardBoxed GBP 1054.85 1
Advanced MxPro 5 MXP-532F General Routing Interface Fitted Advanced MxPro 5 MXP-532FGeneral Routing Interface FittedThe General Routing InterfaceGeneral Routing Interface Card is an optional module to provide fire routing outputs compliant with BS EN54-2 1998 Clauses 7.9 and 8.9 and BS5839-12002Applications LimitationsEN54-2 compliant routing interfaces providing monitored outputs to fire alarm and routing circuits. Circuits are monitored for open and short circuit conditions in both normal and active mode - compliance with EN54-2 and BS5839-1 2002 Clause 12.2.1aThe outputs will drive relay coils with impedances of between 1k and 5k.Key FeaturesTwo fire routing outputs are provided to differentiate between Call Point MCP and Automatic Detector AFD fire alarm signals if required.Outputs are monitored for open and short circuit wiring issues in both the quiescent and active states and fault conditions reported on the panel CIE displayLED Indicators.Outputs are compatible with a wide range of routing equipment.Simple to install and configureMonitored outputsWide range compatibility GBP 279.74 1
Advanced MxPro5 MXP-547 ESPA Pager Interface Advanced MxPro5 MXP-547 ESPA Pager InterfaceThe Pager Interface is a programmable interface providing connectivity of third party paging systems to the MxPro 5 control equipment. It utilises the industry standard protocol ESPA 4.4.4 and connects to the equipment via a serial data connection. An optional input function is available to monitor pager fault conditions. Specific event types e.g. Fire Alarm Pre- Alarm Fault etc. can be sent to individual pagers andor to groups of pagers.Applications LimitationsFor use with pager systems compliant to ESPA 4.4.4 protocol. If a printer is also required fit an internal printer assembly.Key FeaturesUp to 8 configurable shifts per weekdayweekendUp to 50 pager groupsUp to 250 pager addressesEach pager address can be configured to cover 2 zone rangesZone andor point information can be sent to the pagerUser defined texts are available and the basic event type text can be configuredESPA 4.4.4 protocolPanel mounted or boxed versionEasily configured via pager PC Software3 year warranty as standard GBP 915.07 1
Advanced MxPro 5 MXP-532 General Routing Interface Advanced MxPro 5 MXP-532 General Routing InterfaceThe General Routing InterfaceGeneral Routing Interface Card is an optional module to provide fire routing outputs compliant with BS EN54-2 1998 Clauses 7.9 and 8.9 and BS5839-12002Applications LimitationsEN54-2 compliant routing interfaces providing monitored outputs to fire alarm and routing circuits. Circuits are monitored for open and short circuit conditions in both normal and active mode - compliance with EN54-2 and BS5839-1 2002 Clause 12.2.1aThe outputs will drive relay coils with impedances of between 1k and 5k.CompatibilityCan be used with all MxPro 5 series control panels programmed with version 50.07 software or later compatible with the PC-Configuration tool from version 6.12 or later. The interface connects directly to peripheral bus connection in the panel.Key FeaturesTwo fire routing outputs are provided to differentiate between Call Point MCP and Automatic Detector AFD fire alarm signals if required.Outputs are monitored for open and short circuit wiring issues in both the quiescent and active states and fault conditions reported on the panel CIE displayLED Indicators.Outputs are compatible with a wide range of routing equipment.Simple to install and configureMonitored outputsWide range compatibility GBP 279.74 1
Advanced MxPro MXM-533 ModemESPABMS Interface Enclosure Advanced MxPro MXM-533 ModemESPABMS Interface EnclosureThe MxPro 5range of control equipment can be supplied in various sized enclosures to accommodate the internal hardware and battery requirements of the control equipment.There are three standard variations to choose from which can be provided in various depths to meet the customers requirements.Key FeaturesDesigned for IP30 protectionAC terminal block and leadsInternal labellingHinge pins GBP 132.14 1
Advanced MxPro5 MXP-547F ESPA Pager Interface Fitted Advanced MxPro5 MXP-547F ESPA Pager Interface FittedThe Pager Interfaceis a programmable interface providing connectivity of third-party paging systems to the MxPro 5 control equipment.It utilises the industry standard protocol ESPA 4.4.4 and connects to the equipment via a serial data connection. An optional input function is available to monitor pager fault conditions.Specific event types e.g. Fire Alarm Pre- Alarm Fault etc. can be sent to individual pagers andor to groups of pagers.Applications LimitationsFor use with pager systems compliant to ESPA 4.4.4 protocol. If a printer is also required fit an internal printer assembly.Key FeaturesUp to 8 configurable shifts per weekdayweekendUp to 50 pager groupsUp to 250 pager addressesEach pager address can be configured to cover 2 zone rangesZone andor point information can be sent to the pagerUser defined texts are available and the basic event type text can be configuredESPA 4.4.4 protocolPanel mounted or boxed versionEasily configured via pager PC Software3-year warranty as standard GBP 915.07 1