269 results (0,14337 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Advanced MX-5806A 2-8 Loop Fire Panel - 6 Loop Cards - Standard Network - Extended CoreProtocol

Advanced MX-5806A 2-8 Loop Fire Panel - 6 Loop Cards - Standard Network - Extended CoreProtocol

Advanced MX-5806A 2-8 Loop Fire Panel - 6 Loop Cards - StandardNetwork - Extended CoreProtocolThe MxPro 5 series is fully expandable from 2 to 8 loops andsupplied with 8 onboard sounder circuits 20 programmable Zonal LEDs withslide-in labels and 25 System LEDs for information purposes. There are also 8programmable function buttons with LED indication for confirmation ofoperation. The control panel consists of the latest dual flash-based microprocessortechnology combined with a high resolution high contrast graphical LCDdisplay and tactile keypad providing a simple select click programmingaid for engineer configuration and end-user operation.Compatible with AdvancedLive UKI only which is thefire panel monitoring solution that enables secure easy real-time managementof an Advanced fire system.Powerful cause-and-effect programming coupled with dynamic zoningand enhanced Trace Diagnostics makes the panel suitable for a wide range ofsite applications from small to large complex multi-area systems. Fullyprogrammable onsite via the onboard alphanumeric keypad or PC-NeT-022configuration software.An extensive suite of user-friendly Windows-based PCsoftware programs has been developed to enhance your experience when using MxPro 5 series fire panels. The suiteincorporates a number of different programmes to include a configuration serviceand logo tool to allow greater flexibility of the equipment to be fullyexplored.Simply adding a network card allows the panel to communicatewith any other MxPro 5 MxPro 4 fire panel remote terminal or networkperipherals such as BMS or graphical interface. The network operates as a truepeer-to-peer system and can be configured in a fault tolerant loop or radialformat.Key Features Connectivity to AdvancedLive UKI only Etherneton-boardFully expandable from 2 - 8 loops via plug-in loop drivercards.20 programmable Zonal 25 System LEDs with slide-in labels.Apollo Argus Vega Hochiki Nittan Evolution protocol support.Advanced graphical LCD user interface and support for up to 200fire zones by default allowing full EN54 compliance without additionalhardware.Dual flash-based microprocessor technology with real-time clockonboard.Dedicated USB RS232 serial port for direct PC or modemconnection.Installer friendly Auto-learn Loop Detection and Onboard Scopefacility for ease of commissioning and fault finding.Fully programmable via the onboard alphanumeric keypad or PCconfiguration tools.The graphical display can be configured to operate with virtuallyany language or character set and allowthe installers logo to be applied using the Logo application software.Robust removable equipment chassis with plug-in connectors forsimple fixing and cable termination.Integral P-Bus for system expansion via available option cards.Advanced networking peer-to-peer system withup to 2000 zones

GBP 5398.30
1

Advanced MX-5806AFT 2-8 Loop Fire Panel - 6 Loop Cards - Fault-Tolerant - Extended CoreProtocol

Advanced MX-5806AFT 2-8 Loop Fire Panel - 6 Loop Cards - Fault-Tolerant - Extended CoreProtocol

Advanced MX-5806AFT 2-8 Loop Fire Panel - 6 Loop Cards - Fault-Tolerant- Extended CoreProtocolThe MxPro 5 seriesis fully expandable from 2 to 8 loops and supplied with 8 onboard soundercircuits 20 programmable Zonal LEDs with slide-in labels and 25 System LEDsfor information purposes. There are also 8 programmable function buttons withLED indication for confirmation of operation. The control panel consists of thelatest dual flash-based microprocessor technology combined with a highresolution high contrast graphical LCD display and tactile keypad providing asimple select click programming aid for engineer configuration andend-user operation.Compatible with AdvancedLive UKI only which is thefire panel monitoring solution that enables secure easy real-time managementof an Advanced fire system.Powerful cause-and-effect programming coupled with dynamic zoningand enhanced Trace Diagnostics makes the panel suitable for a wide range ofsite applications from small to large complex multi-area systems. Fullyprogrammable onsite via the onboard alphanumeric keypad or PC-NeT-022configuration software.An extensive suite of user-friendly Windows-based PCsoftware programs has been developed to enhance your experience when using MxPro 5 series fire panels. The suiteincorporates a number of different programmes to include a configuration serviceand logo tool to allow greater flexibility of the equipment to be fullyexplored.Simply adding a network card allows the panel to communicatewith any other MxPro 5 MxPro 4 fire panel remote terminal or networkperipherals such as BMS or graphical interface. The network operates as a truepeer-to-peer system and can be configured in a fault tolerant loop or radialformat.Key Features Connectivity to AdvancedLive UKI only Etherneton-boardFully expandable from 2 - 8 loops via plug-in loop drivercards.20 programmable Zonal 25 System LEDs with slide-in labels.Apollo Argus Vega Hochiki Nittan Evolution protocol support.Advanced graphical LCD user interface and support for up to 200fire zones by default allowing full EN54 compliance without additionalhardware.Dual flash-based microprocessor technology with real-time clockonboard.Dedicated USB RS232 serial port for direct PC or modemconnection.Installer friendly Auto-learn Loop Detection and Onboard Scopefacility for ease of commissioning and fault finding.Fully programmable via the onboard alphanumeric keypad or PCconfiguration tools.The graphical display can be configured to operate with virtuallyany language or character set and allowthe installers logo to be applied using the Logo application software.Robust removable equipment chassis with plug-in connectors forsimple fixing and cable termination.Integral P-Bus for system expansion via available option cards.Advanced networking peer-to-peer system withup to 2000 zones.

GBP 6076.76
1

Advanced Fault Tolerant 2-8 Loop MxPro5 Panel with 6 Loop Cards MX-5806NFT Nittan Evolution Protocol

Advanced Fault Tolerant 2-8 Loop MxPro5 Panel with 6 Loop Cards MX-5806NFT Nittan Evolution Protocol

Advanced Fault Tolerant 2-8 Loop MxPro5 Panel with 6 Loop Cards MX-5806NFT Nittan Evolution ProtocolThe MxPro 5 series is fully expandable from 2 to 8 loops and supplied with 8 on-board sounder circuits 20 programmable Zonal LEDs with slide-in labels and 25 System LEDs for information purposes. There are also 8 programmable function buttons with LED indication for confirmation of operation. The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple select click programming aid for engineer configuration and end-user operation. Powerful cause-and-effect programming coupled with dynamic zoning and enhanced Trace Diagnostics makes the panel suitable for a wide range of site applications from small to large complex multi-area systems.Fully programmable onsite via the on-board alphanumeric keypad or PC-NeT configuration software. An extensive suite of user-friendly Windows based PC software programs has been developed to enhance your experience when using MxPro 5 series fire panels. The suite incorporates a number of different programmes to include a configuration service logo and virtual panel tool to allow the flexibility of the equipment to be fully explored. Simply adding a network card allows the panel to communicate with any other MxPro 5MxPro 4 fire panel remote terminal or network peripheral such as ipGateway or BMSgraphical interface. The network operates as a true peer-to-peer system and can be configured in a fault tolerant loop or radial format.Key FeaturesFully expandable from 2 - 8 loops via plug-in loop driver boards.20 programmable Zonal 25 System LEDs with slide-in labels. Dedicated loop driver for Apollo or Hochiki protocol support.Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardware.Dual flash-based microprocessor technology with real-time clock on-board.Dedicated USB RS232 serial port for direct PC or modem connection.Installer friendly Auto-learn Loop Detection and On-board Scope facility for ease of commissioning and fault finding.Fully programmable via the on-board alphanumeric keypad or PC configuration tools.The graphical display can be configured to operate with virtually any language or character set and allow the installers logo to be applied using the Logo application software.Robust removable equipment chassis with plug-in connectors for simple fixing and cable termination.2 x 5 Amp power supply and charger to En54 part 4.Integral P-Bus for system expansion via available option cards.Ad-NeT peer-to-peer network with up to 2000 zones.

GBP 6076.76
1

Advanced Fault Tolerant 2-8 Loop MxPro5 Panel with 6 Loop Cards MX-5806FT Apollo Hochiki Protocol

Advanced Fault Tolerant 2-8 Loop MxPro5 Panel with 6 Loop Cards MX-5806FT Apollo Hochiki Protocol

Advanced Fault Tolerant 2-8 Loop MxPro5 Panel with 6 Loop Cards MX-5806FT Apollo Hochiki ProtocolThe MxPro 5 series is fully expandable from 2 to 8 loops and supplied with 8 on-board sounder circuits 20 programmable Zonal LEDs with slide-in labels and 25 System LEDs for information purposes. There are also 8 programmable function buttons with LED indication for confirmation of operation. The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple select click programming aid for engineer configuration and end-user operation.Powerful cause-and-effect programming coupled with dynamic zoning and enhanced Trace Diagnostics makes the panel suitable for a wide range of site applications from small to large complex multi-area systems. Fully programmable onsite via the on-board alphanumeric keypad or PC-NeT configuration software. An extensive suite of user-friendly Windows based PC software programs has been developed to enhance your experience when using MxPro 5 series fire panels.The suite incorporates a number of different programmes to include a configuration service logo and virtual panel tool to allow the flexibility of the equipment to be fully explored. Simply adding a network card allows the panel to communicate with any other MxPro 5MxPro 4 fire panel remote terminal or network peripheral such as ipGateway or BMSgraphical interface. The network operates as a true peer-to-peer system and can be configured in a fault tolerant loop or radial format.Key FeaturesFully expandable from 2 - 8 loops via plug-in loop driver boards.20 programmable Zonal 25 System LEDs with slide-in labels. Dedicated loop driver for Apollo or Hochiki protocol support.Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardware.Dual flash-based microprocessor technology with real-time clock on-board.Dedicated USB RS232 serial port for direct PC or modem connection.Installer friendly Auto-learn Loop Detection and On-board Scope facility for ease of commissioning and fault finding.Fully programmable via the on-board alphanumeric keypad or PC configuration tools.The graphical display can be configured to operate with virtually any language or character set and allow the installers logo to be applied using the Logo application software.Robust removable equipment chassis with plug-in connectors for simple fixing and cable termination.2 x 5 Amp power supply and charger to En54 part 4.Integral P-Bus for system expansion via available option cards.Ad-NeT peer-to-peer network with up to 2000 zones.

GBP 6076.76
1

Advanced 2-8 Loop MxPro 5 Fire Control Panel with 6 Loop Cards MX-5806V Argus Vega Protocol

Advanced 2-8 Loop MxPro 5 Fire Control Panel with 6 Loop Cards MX-5806V Argus Vega Protocol

Advanced 2-8 Loop MxPro 5 Fire Control Panel with 6 Loop Cards MX-5806V Argus Vega ProtocolThe MxPro 5 series is fully expandable from 2 to 8 loops and supplied with 8 on-board sounder circuits 20 programmable Zonal LEDs with slide-in labels and 25 System LEDs for information purposes. There are also 8 programmable function buttons with LED indication for confirmation of operation. The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple select click programming aid for engineer configuration and end-user operation.Powerful cause-and-effect programming coupled with dynamic zoning and enhanced Trace Diagnostics makes the panel suitable for a wide range of site applications from small to large complex multi-area systems. Fully programmable onsite via the on-board alphanumeric keypad or PC-NeT configuration software. An extensive suite of user-friendly Windows based PC software programs has been developed to enhance your experience when using MxPro 5 series fire panels.The suite incorporates a number of different programmes to include a configuration service logo and virtual panel tool to allow the flexibility of the equipment to be fully explored. Simply adding a network card allows the panel to communicate with any other MxPro 5MxPro 4 fire panel remote terminal or network peripheral such as ipGateway or BMSgraphical interface. The network operates as a true peer-to-peer system and can be configured in a fault tolerant loop or radial format.Key FeaturesFully expandable from 2 - 8 loops via plug-in loop driver boards.20 programmable Zonal 25 System LEDs with slide-in labels. Dedicated loop driver for Apollo or Hochiki protocol support.Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardware.Dual flash-based microprocessor technology with real-time clock on-board.Dedicated USB RS232 serial port for direct PC or modem connection.Installer friendly Auto-learn Loop Detection and On-board Scope facility for ease of commissioning and fault finding.Fully programmable via the on-board alphanumeric keypad or PC configuration tools.The graphical display can be configured to operate with virtually any language or character set and allow the installers logo to be applied using the Logo application software.Robust removable equipment chassis with plug-in connectors for simple fixing and cable termination.2 x 5 Amp power supply and charger to En54 part 4.Integral P-Bus for system expansion via available option cards.Ad-NeT peer-to-peer network with up to 2000 zones.

GBP 5398.30
1

Advanced 2-8 Loop MxPro 5 Fire Control Panel with 6 Loop Cards MX-5806N Nittan Evolution Protocol

Advanced 2-8 Loop MxPro 5 Fire Control Panel with 6 Loop Cards MX-5806N Nittan Evolution Protocol

Advanced 2-8 Loop MxPro 5 Fire Control Panel with 6 Loop Cards MX-5806N Nittan Evolution ProtocolThe MxPro 5 series is fully expandable from 2 to 8 loops and supplied with 8 on-board sounder circuits 20 programmable Zonal LEDs with slide-in labels and 25 System LEDs for information purposes. There are also 8 programmable function buttons with LED indication for confirmation of operation. The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple select click programming aid for engineer configuration and end-user operation. Powerful cause-and-effect programming coupled with dynamic zoning and enhanced Trace Diagnostics makes the panel suitable for a wide range of site applications from small to large complex multi-area systems.Fully programmable onsite via the on-board alphanumeric keypad or PC-NeT configuration software. An extensive suite of user-friendly Windows based PC software programs has been developed to enhance your experience when using MxPro 5 series fire panels. The suite incorporates a number of different programmes to include a configuration service logo and virtual panel tool to allow the flexibility of the equipment to be fully explored. Simply adding a network card allows the panel to communicate with any other MxPro 5MxPro 4 fire panel remote terminal or network peripheral such as ipGateway or BMSgraphical interface. The network operates as a true peer-to-peer system and can be configured in a fault tolerant loop or radial format.Key FeaturesFully expandable from 2 - 8 loops via plug-in loop driver boards.20 programmable Zonal 25 System LEDs with slide-in labels. Dedicated loop driver for Apollo or Hochiki protocol support.Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardware.Dual flash-based microprocessor technology with real-time clock on-board.Dedicated USB RS232 serial port for direct PC or modem connection.Installer friendly Auto-learn Loop Detection and On-board Scope facility for ease of commissioning and fault finding.Fully programmable via the on-board alphanumeric keypad or PC configuration tools.The graphical display can be configured to operate with virtually any language or character set and allow the installers logo to be applied using the Logo application software.Robust removable equipment chassis with plug-in connectors for simple fixing and cable termination.2 x 5 Amp power supply and charger to En54 part 4.Integral P-Bus for system expansion via available option cards.Ad-NeT peer-to-peer network with up to 2000 zones.

GBP 5398.30
1

Advanced Fault Tolerant 2-8 Loop MXPRO 5 Panel with 6 Loop Cards MX-5806VFT Argus Vega Protocol

Advanced Fault Tolerant 2-8 Loop MXPRO 5 Panel with 6 Loop Cards MX-5806VFT Argus Vega Protocol

Advanced Fault Tolerant 2-8 Loop MXPRO 5 Panel with 6 Loop Cards MX-5806VFT Argus Vega ProtocolThe MxPro 5 series is fully expandable from 2 to 8 loops and supplied with 8 on-board sounder circuits 20 programmable Zonal LEDs with slide-in labels and 25 System LEDs for information purposes. There are also 8 programmable function buttons with LED indication for confirmation of operation. The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple select click programming aid for engineer configuration and end-user operation.Powerful cause-and-effect programming coupled with dynamic zoning and enhanced Trace Diagnostics makes the panel suitable for a wide range of site applications from small to large complex multi-area systems. Fully programmable onsite via the on-board alphanumeric keypad or PC-NeT configuration software. An extensive suite of user-friendly Windows based PC software programs has been developed to enhance your experience when using MxPro 5 series fire panels.The suite incorporates a number of different programmes to include a configuration service logo and virtual panel tool to allow the flexibility of the equipment to be fully explored. Simply adding a network card allows the panel to communicate with any other MxPro 5MxPro 4 fire panel remote terminal or network peripheral such as ipGateway or BMSgraphical interface. The network operates as a true peer-to-peer system and can be configured in a fault tolerant loop or radial format.Key FeaturesFully expandable from 2 - 8 loops via plug-in loop driver boards.20 programmable Zonal 25 System LEDs with slide-in labels. Dedicated loop driver for Apollo or Hochiki protocol support.Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardware.Dual flash-based microprocessor technology with real-time clock on-board.Dedicated USB RS232 serial port for direct PC or modem connection.Installer friendly Auto-learn Loop Detection and On-board Scope facility for ease of commissioning and fault finding.Fully programmable via the on-board alphanumeric keypad or PC configuration tools.The graphical display can be configured to operate with virtually any language or character set and allow the installers logo to be applied using the Logo application software.Robust removable equipment chassis with plug-in connectors for simple fixing and cable termination.2 x 5 Amp power supply and charger to En54 part 4.Integral P-Bus for system expansion via available option cards.Ad-NeT peer-to-peer network with up to 2000 zones.

GBP 6076.76
1

Advanced 2-8 Loop MxPro 5 Fire Control Panel with 6 Loop Cards MX-5806 Apollo Hochiki Protocol

Advanced 2-8 Loop MxPro 5 Fire Control Panel with 6 Loop Cards MX-5806 Apollo Hochiki Protocol

Advanced 2-8 Loop MxPro 5 Fire Control Panel with 6 Loop Cards MX-5806 Apollo Hochiki ProtocolThe MxPro 5 series is fully expandable from 2 to 8 loops and supplied with 8 on-board sounder circuits 20 programmable Zonal LEDs with slide-in labels and 25 System LEDs for information purposes. There are also 8 programmable function buttons with LED indication for confirmation of operation. The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple select click programming aid for engineer configuration and end-user operation.Powerful cause-and-effect programming coupled with dynamic zoning and enhanced Trace Diagnostics makes the panel suitable for a wide range of site applications from small to large complex multi-area systems. Fully programmable onsite via the on-board alphanumeric keypad or PC-NeT configuration software. An extensive suite of user-friendly Windows based PC software programs has been developed to enhance your experience when using MxPro 5 series fire panels.The suite incorporates a number of different programmes to include a configuration service logo and virtual panel tool to allow the flexibility of the equipment to be fully explored. Simply adding a network card allows the panel to communicate with any other MxPro 5MxPro 4 fire panel remote terminal or network peripheral such as ipGateway or BMSgraphical interface. The network operates as a true peer-to-peer system and can be configured in a fault tolerant loop or radial format.Key FeaturesFully expandable from 2 - 8 loops via plug-in loop driver boards.20 programmable Zonal 25 System LEDs with slide-in labels. Dedicated loop driver for Apollo or Hochiki protocol support.Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardware.Dual flash-based microprocessor technology with real-time clock on-board.Dedicated USB RS232 serial port for direct PC or modem connection.Installer friendly Auto-learn Loop Detection and On-board Scope facility for ease of commissioning and fault finding.Fully programmable via the on-board alphanumeric keypad or PC configuration tools.The graphical display can be configured to operate with virtually any language or character set and allow the installers logo to be applied using the Logo application software.Robust removable equipment chassis with plug-in connectors for simple fixing and cable termination.2 x 5 Amp power supply and charger to En54 part 4.Integral P-Bus for system expansion via available option cards.Ad-NeT peer-to-peer network with up to 2000 zones.

GBP 5398.30
1

Advanced 1-2 Loop MxPro5 Fire Control Panel with 2 Loop Cards MX-5202V Argus Vega

Advanced 1-2 Loop MxPro5 Fire Control Panel with 2 Loop Cards MX-5202V Argus Vega

Advanced 1-2 Loop MxPro5 Fire Control Panel with 2 Loop Cards MX-5202V Argus VegaThe MxPro 5 series control panels are fully expandable from 1 - 2 loops and supplied with 2 on-board sounder circuits 20 programmable zonal LEDs with slide-in labels and 25 system LEDs for information purposes. There are also 4 programmable function buttons with LED indication for confirmation of operation.The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple select and click programming aid for engineer configuration and end user operation.Powerful cause-and-effect programming and enhanced trace diagnostics makes the panel suitable for a wide range of site applications from small to large complex multi-area systems. Fully programmable onsite via the on-board alphanumeric keypad or PC-NeT configuration software.PC Software An extensive suite of user-friendly Windows based PC software programs has been developed to enhance your experience when using MxPro 5 Series of Fire panels. The suite incorporates a number of different programmes to include a configuration service logo and virtual panel tool to allow the flexibility of the equipment to be fully explored.Network Simply adding a network card allows the panel to communicate with any other MxPro 5MxPro 4 fire panel remote terminal or network peripheral such as ipGateway or BMSGraphical Interface. The network operates as a true peer-topeer system and can be configured in a fault-tolerant loop or radial format.Key FeaturesApollo Argus Vega Hochiki Nittan Evolution protocol support.Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardware.Dual flash-based microprocessor technology with real-time clock on-board.Dedicated USB RS232 serial port for direct PC or modem connection.Installer friendly Auto-learn Loop Detection and On-board Scope facilities for ease of commissioning and fault finding.Graphical display configurable for virtually any languageRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination.Fully programmable via the on-board alphanumeric keypad or PC configuration tools.Integral P-Bus for system expansion via available option cardsAd-NeT peer-to-peer network with up to 2000 zonesApproved to BS EN54 part 2 4 and 13Part NumberDescriptionMX-5202V1-2 Loop Fire Panel cw 2 loop cards in Medium enc.MX-5202VL1-2 Loop Fire Panel cw 2 loop cards in Large enc.MX-5202VD1-2 Loop Fire Panel cw 2 loop cards in Large-Deep enc.MX-5202VR1-2 Loop 19 Rack Mount FACP cw 2 loop cards

GBP 1542.98
1

Advanced 1-2 Loop MxPro5 Fire Control Panel with 2 Loop Cards MX-5202N Nittan Evolution Protocol

Advanced 1-2 Loop MxPro5 Fire Control Panel with 2 Loop Cards MX-5202N Nittan Evolution Protocol

Advanced 1-2 Loop MxPro5 Fire Control Panel with 2 Loop Cards MX-5202N Nittan Evolution ProtocolThe MxPro 5 series control panels are fully expandable from 1 - 2 loops and supplied with 2 on-board sounder circuits 20 programmable zonal LEDs with slide-in labels and 25 system LEDs for information purposes. There are also 4 programmable function buttons with LED indication for confirmation of operation.The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple select and click programming aid for engineer configuration and end user operation. Powerful cause-and-effect programming and enhanced trace diagnostics makes the panel suitable for a wide range of site applications from small to large complex multi-area systems. Fully programmable onsite via the on-board alphanumeric keypad or PC-NeT configuration software.PC Software An extensive suite of user-friendly Windows based PC software programs has been developed to enhance your experience when using MxPro 5 Series of Fire panels. The suite incorporates a number of different programmes to include a configuration service logo and virtual panel tool to allow the flexibility of the equipment to be fully explored.Network Simply adding a network card allows the panel to communicate with any other MxPro 5MxPro 4 fire panel remote terminal or network peripheral such as ipGateway or BMSGraphical Interface. The network operates as a true peer-topeer system and can be configured in a fault-tolerant loop or radial format.Key FeaturesApollo Argus Vega Hochiki Nittan Evolution protocol support.Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardware.Dual flash-based microprocessor technology with real-time clock on-board.Dedicated USB RS232 serial port for direct PC or modem connection.Installer friendly Auto-learn Loop Detection and On-board Scope facilities for ease of commissioning and fault finding.Graphical display configurable for virtually any languageRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination.Fully programmable via the on-board alphanumeric keypad or PC configuration tools.Integral P-Bus for system expansion via available option cardsAd-NeT peer-to-peer network with up to 2000 zonesApproved to BS EN54 part 2 4 and 13Part NumberDescriptionMX-5202N1-2 Loop Fire Panel cw 2 loop cards in Medium enc.MX-5202NL1-2 Loop Fire Panel cw 2 loop cards in Large enc.MX-5202ND1-2 Loop Fire Panel cw 2 loop cards in Large-Deep enc.MX-5202NR1-2 Loop 19 Rack Mount FACP cw 2 loop cards

GBP 1542.98
1

Advanced 1-2 Loop MxPro5 Fire Control Panel with 2 Loop Cards MX-5202 Apollo Hochiki Protocol

Advanced 1-2 Loop MxPro5 Fire Control Panel with 2 Loop Cards MX-5202 Apollo Hochiki Protocol

Advanced 1-2 Loop MxPro5 Fire Control Panel with 2 Loop Cards MX-5202 Apollo Hochiki ProtocolThe MxPro 5 series control panels are fully expandable from 1 - 2 loops and supplied with 2 on-board sounder circuits 20 programmable zonal LEDs with slide-in labels and 25 system LEDs for information purposes. There are also 4 programmable function buttons with LED indication for confirmation of operation.The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple select and click programming aid for engineer configuration and end user operation.Powerful cause-and-effect programming and enhanced trace diagnostics makes the panel suitable for a wide range of site applications from small to large complex multi-area systems. Fully programmable onsite via the on-board alphanumeric keypad or PC-NeT configuration software.PC Software An extensive suite of user-friendly Windows based PC software programs has been developed to enhance your experience when using MxPro 5 Series of Fire panels. The suite incorporates a number of different programmes to include a configuration service logo and virtual panel tool to allow the flexibility of the equipment to be fully explored.Network Simply adding a network card allows the panel to communicate with any other MxPro 5MxPro 4 fire panel remote terminal or network peripheral such as ipGateway or BMSGraphical Interface. The network operates as a true peer-topeer system and can be configured in a fault-tolerant loop or radial format.Key FeaturesApollo Argus Vega Hochiki Nittan Evolution protocol support.Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardware.Dual flash-based microprocessor technology with real-time clock on-board.Dedicated USB RS232 serial port for direct PC or modem connection.Installer friendly Auto-learn Loop Detection and On-board Scope facilities for ease of commissioning and fault finding.Graphical display configurable for virtually any languageRobust removable equipment chassis with plug-in connectors for simple fixing and cable termination.Fully programmable via the on-board alphanumeric keypad or PC configuration tools.Integral P-Bus for system expansion via available option cardsAd-NeT peer-to-peer network with up to 2000 zonesApproved to BS EN54 part 2 4 and 13Part NumberDescriptionMX-52021-2 Loop Fire Panel cw 2 loop cards in Medium enc.MX-5202L1-2 Loop Fire Panel cw 2 loop cards in Large enc.MX-5202D1-2 Loop Fire Panel cw 2 loop cards in Large-Deep enc.MX-5202R1-2 Loop 19 Rack Mount FACP cw 2 loop cards

GBP 1542.98
1

Advanced QZ-2 QuickZone 2 Zone Conventional Control Panel

Advanced QZ-2 QuickZone 2 Zone Conventional Control Panel

Advanced QuickZone 2 Zone Conventional Control Panel - QZ-2QuickZone is a 2 or 4 zone Conventional Twin Wire sav-wire control panel with integral power supply space for standby batteries. The panel continues the attributes of quality and reliability that is ways to install maintain and is simple to operate for the end user. Two or four fire zone circuits are provided plus two monitored sounder circuits. Fire and fault VFCO relays Fire Fault switched negative outputs class change and an alert input are also included.The fire zone outputs can be set as Twin Wire by DIL switch selection. The DIL switches are also used to allow Zone interface setting and Access to Level 3 mode. In Level 1 the panel will indicate if there are any faults Supply Fire System or General. As well as this the panel is capable of indicating zones in Fire Fault and disablements. Auxiliary Output and Sounder status will be shown including if the panel is in test mode. Controls enabled in Level 2 include Resound Silence and Reset.Disable and Test modes can also be established at this level as well as muting the internal buzzer and testing the functionality of all the LED indicators. In access Level 3 it is possible to select sounder resound options for zones EN54 requirement select Type A dependency per view and edit dependency functions as well as restore factory settings. The buzzer volume can also be set.Key Features2 or 4 zoneTwin Wire selection by DIL switchApproved to EN54-2 43 year warranty as standardSimple colour coded buttons for controls and programmingIntegral 1 amp switch mode PSUClass change alert inputsFire fault relays2 monitored sounder circuitsTest modeSpace for up to 3.2Ah batteriesKey-switch or code entry for activation of controls

GBP 284.90
1

Advanced ExGo 2 Way Relay Output Card - EXP-007

Advanced MXP-507 2-Way Relay Card MxPro 5