Hochiki TE-RH-E End Of Line Unit Hochiki TE-RH-E End Of Line UnitAn End Of Line Unit for Hochiki CHQ Zone Modules. GBP 0.96 1
RGL Electronics DU-COVER Replacement Cover For The Dual Unit Products Single RGL Electronics DU-COVER Replacement Cover For The Dual Unit Products SingleA replacement cover for the following Dual UnitsDU-GBPTEDU-SSPTEDU-NTTFDU-KS1DU-KS2 GBP 3.91 1
Vimpex 10-2011WFR-S Identifire Flush Remote Indicator Unit Vimpex 10-2011WFR-S Identifire Flush Remote Indicator UnitThe 10-2011WFR-S is a bright LED indicator suitable for use on both conventional and analogue addressable alarm systems. Like all Identifire products this product is available as either flush or surface mounted.Key FeaturesVery bright easily visible LEDSuitable for use on both conventional and addressable alarm systemsOperating Voltage 5 - 28 V dcSuitable for use with both conventional and analogue addressable alarm systems GBP 4.12 1
Fike 900-0003 ASD Deep Back Box Fike 900-0003 ASD Deep Back BoxThe 900-0003 ASD deep back box suitable for surface mount cable termination of cables with trunking conduit or glands.Key FeaturesThis unit is only suitable for use with the bases of Fike ASD Detectors GBP 3.70 1
Kentec M24000 Remote Indicator Ceiling Clip for round version Kentec M24000 Remote Indicator Ceiling Clip for round versionKentec have released a new and unique ceiling mounting clip which provides fast and secure fixing of their round Remote Indicator unit to ceilings.It is particularly good for fragile ceilings such as suspended ceilings. GBP 3.43 1
RGL Electronics EDR-COVER-N Replacement Cover For EDR Products - Single Unit RGL Electronics EDR-COVER-N Replacement Cover For EDR Products - Single UnitThis Transparent Hinged Cover has been designed to fit all EDR-N model Manual Call Points and provides protection against accidental operation. GBP 3.91 1
Fireclass 515.001.127FC Deformable FC400 MCP Element Fireclass 515.001.127FC Deformable FC400 MCP ElementThe 515.001.127FC is a deformable operating unit glass for use in place of glasses for kitchens or other areas where glass is not acceptable. The element allows a call point device to be reset using the key supplied after alarm activation.Key FeaturesDesigned for conventional call points GBP 1.60 1
Cranford Controls RIU-01 Blank Remote Indication Units Cranford Controls RIU-01 Blank Remote Indication UnitsThe RIU unit is used to give a remote indication of the status of a single or groups of fire detectors in alarm state utilising an LED with a wide area of illumination and high onoff contrast. The units are compatible with the majority of conventional and addressable systems and can also be used for security and process control applications. The standard version is a single gang flush mount unit with or without Fire Detector Operated text and also available with a deep back box for surface mounting.Key Featuresdirect fit to a single gang deep back boxcircular flush mounted version available without texttext is available in other languagescustom legend available on requestIP66 weather-proof version availableVariants AvailablePart NumberDescription502-001Blank - Flush RIU-01502-002Blank - Surface RIU-01B GBP 3.62 1
Cranford Controls RIU-02 Fire Detector Operated Remote Indication Units 502-003 Cranford Controls RIU-02 Fire Detector Operated Remote Indication Units502-003The RIU unit is used to give a remote indication of the status of a single or groups of fire detectors in alarm state utilising an LED with a wide area of illumination and high onoff contrast. The units are compatible with the majority of conventional and addressable systems and can also be used for security and process control applications. The standard version is a single gang flush mount unit with or without Fire Detector Operated text and also available with a deep back box for surface mountingKey FeaturesDirect fit to a single gang deep back boxcircular flush mounted version available without texttext is available in other languagescustom legend available on requestIP66 weather-proof version availableVariants AvailablePart NumberDescription502-003Fire Detector Operated text - Flush RIU-02502-004Fire Detector Operated text - Surface RIU-02B GBP 3.62 1
CO2 T Bracket for 2KG Extinguishers - CD2BRT CO2 T Bracket for 2KG Extinguishers - CD2BRTThe CO2 T Bracket is designed to mount CO2 fire extinguishers and gives extra support to the extinguishers. The Plastic cradle helps keep the extinguisher in place protecting the unit when knocked.Easily mountable mild steel bracket supplied to hold a 2kg CO2extinguisher.Key FeaturesSolid Steel construction.Zinc plated for aesthetic appearance.Supplied with plastic cradle to protect the extinguisher from damage GBP 1.04 1
CO2 T Bracket for 5kg Extinguishers - CD5BRT CO2 T Bracket for 5kg Extinguishers - CD5BRTThe CO2 T Bracket is designed to mount CO2 fire extinguishers and gives extra support to the extinguishers. The Plastic cradle helps keep the extinguisher in place protecting the unit when knocked.Easily mountable mild steel bracket supplied to hold a 5kg CO2extinguisher.Key FeaturesSolid Steel construction.Zinc plated for aesthetic appearance.Supplied with plastic cradle to protect the extinguisher from damage GBP 1.99 1
Apollo XP95 EN54 Glass Replacement 26729-154 Apollo XP95 EN54 Glass Replacement 26729-154Singular replacement break glass for the KAC range of manual call points. In the event of an emergency it may be necessary to activate a manual call point by pressing on the break glass element breaking the glass to activate the fire alarm system. After the call point has been activated the call point will require an easy-to-fit replacement break glass to restore the unit performance.Key FeaturesEasy to useSingular replacement glass GBP 1.04 1
Fireclass 515.001.128FC Manual Call Point Plastic Hinged Cover Fireclass 515.001.128FC Manual Call Point Plastic Hinged CoverFireclass manual call point covers provide a cost effective solution in preventing accidental activation. They fit most standard conventional and addressable manual call points or break glass units as well as standard access control break glass units.They are ideal for use in public areas or areas with high volumes of traffic such as schools and crechesKey FeaturesConstructed of clear polycarbonateHinged cover clip on unitNo installation requiredDesigned so there is no interference with the operation of the protected unit GBP 2.24 1
CO2 Discharge Horns - Frost Free Horn CDFFH CO2Discharge Horns - Frost Free Horn CDFFHTraditionally on discharge the surface temperature of a standard CO2 fire extinguisher horn falls rapidly increasing the risk of freeze burn injury if held. The new frost free horn provides a user friendly alternative making the unit safer to hold during fire extinguisher discharge.Key FeaturesSuitable for use on most makes of 2kg CO2 fire extinguishersDouble lined to provide a frost free elementSafe to hold during fire extinguisher operationEnds the risk of freeze burnsIncreases the class B fire rating performanceEasy to installHelps to increase confidence in CO2 fire extinguisher use GBP 3.14 1
C-Tec BF318 Remote LED Indicator Single Gang C-Tec BF318 Remote LED Indicator Single GangThe BF318 is a high quality remote LED indicator specifically designed for use in fire alarm systems. It incorporates a high intensity wide-angle red LED which is clearly visible from the front of the plate when active. Its primary use is to indicate the activation of hidden or out of-sight fire detectors.Key FeaturesThe front label includes a white write on panel allowing installers to add their own personalised text such as equipment locationsThe unit will fit on 16mm deep flush or surface mount back boxes GBP 4.00 1
Ziton Z-AUXD-2P Deep Base Mounting Polar White Ziton Z-AUXD-2P Deep Base Mounting Polar WhiteThe Z-AUXD-2P is a surface mounting base accessory that allows detectors to be installed using standard 20 or 25 mm electrical conduit. Four flat surfaces are provided on the wall of the moulding to accommodate side entry glands together with a breakout in the base of the unit for rear entry cables.The Z-AUXD-2P is compatible with all ZP7 and Z6 series detector bases. It features fixing slots for either direct ceiling mounting or alternate connection to most standard conduit boxes.Key FeaturesAccepts conduit sizes up to 25 mmCompatible with all ZP7 and Z6 series detector basesSide and rear wiring entry GBP 3.78 1
Cooper Fulleon 593001FULL-0022 Deep Red Base for Cooper Fulleon Devices Cooper Fulleon 593001FULL-0022 Deep Red Base for Cooper Fulleon DevicesThe bayonet base has been designed to allow a common mounting for most of Fulleons conventional alarm products. The deep bases cater for surface wiring of all types and provide ingress protection up to IP65. Combinations of two or more Deep bases form the basis of the AV Unit allowing for many permutations of audible and visual warning units.Key FeaturesFulleons design registered Bayonet baseLocking facility on all versionsProtection up to IP65ABS Plastic MaterialSuits most AC mains supply without adjustmentProvides 24V products with extra flexibilityMatches product finishCompatible with most wiring systemsWide input moduleRobust designExternal use in areas of high humidityAllowing installation with minimum impact GBP 2.24 1
Cooper Fulleon Deep White Base for Cooper Fulleon Devices 593002FULL-0017 Cooper Fulleon 593002FULL-0017 Deep White Base for Cooper Fulleon DevicesThe bayonet base has been designed to allow a common mounting for most of Fulleons conventional alarm products. The deep bases cater for surface wiring of all types and provide ingress protection up to IP65. Combinations of two or more Deep bases form the basis of the AV Unit allowing for many permutations of audible and visual warning units.Key FeaturesFulleons design registered Bayonet baseLocking facility on all versionsProtection up to IP65ABS Plastic MaterialSuits most AC mains supply without adjustmentProvides 24V products with extra flexibilityMatches product finishCompatible with most wiring systemsWide input moduleRobust designExternal use in areas of high humidityAllowing installation with minimum impact GBP 2.24 1
Hochiki Conventional Schottky Base YBN-R6SKWHT White Hochiki Conventional Schottky Base YBN-R6SKWHT WhiteModel YBN-R6SKWHT is a Conventional Detector Mounting Base with in-line Schottky Diode associated with the CDX Range of Detectors and is fully compatible with the majority of existing conventional fire alarm control panels.It is supplied with square cable clamps for secure and reliable cable termination and the base provides line continuity during detector removal. Therefore Call Points can be wired in any order on the zone providing a suitable panel and End Of Line EOL unit is used. The integrated third terminal provides remote indicator output.Key FeaturesIntegral remote indicator outputIn-line Schottky Diode for line continuityLow profile only 8mmRugged designQuick connections via square cable clampsAccepts 2.5mm cablesBayonet slot low insertion force for detectorsApproved by LPCB GBP 3.11 1
Hochiki Conventional Schottky Base YBN-R6SK Ivory Hochiki Conventional Schottky Base YBN-R6SK IvoryModel YBN-R6SK is a Conventional Detector Mounting Base with in-line Schottky Diode associated with the CDX Range of Detectors and is fully compatible with the majority of existing conventional fire alarm control panels.It is supplied with square cable clamps for secure and reliable cable termination and the base provides line continuity during detector removal. Therefore Call Points can be wired in any order on the zone providing a suitable panel and End Of Line EOL unit is used. The integrated third terminal provides remote indicator output.Key FeaturesIntegral remote indicator outputIn-line Schottky Diode for Line ContinuityLow Profile only 8 mmRugged designQuick connections via square cable clampsAccepts 2.5 mm cablesBayonet slot low insertion force for detectors GBP 3.11 1
Detector Base For HFI Range HFI-DMBS-05 Detector Base For HFI RangeThe HFI-DMBS-05 is a detector base for the HFI Hyfire range.The HFI-DMBS-05 standard intelligent low profile mounting base has been designed for use with any of the Altair point type intelligent detector range. The bases layout allows plenty of space for cable access and has multiple mounting-hole positions for use with a variety of back boxes. The unit has terminations for loop wiring remote indicator connection and termination of shield cabling. When no device is fitted into the base an automatic spring connection maintains loop continuity ready for loop cable testing. Once the device is refitted the spring is displaced allowing the loop isolators to operate.Key FeaturesHigh reliabilityCompatible with all Altair detectorsDevice locking capabilityEasy central cable entryIntegral device identification tabRemote indicator connectionsBuilt-in continuity spring5 year product warranty GBP 2.90 1