Kentec Sigma CP Sounder PCB K461 Kentec Sigma CP Sounder PCB K461The Sigma CP Sounder Board is compatible with all Sigma CP control panels which have operating software version V3.0 or above. The board provides 8 additional sounder outputs which can be configured as zoned 2-stage or common alarm. All sounder outputs are open and short circuit monitored and any faults on the sounder outputs will be announced at the main fire alarm panel as a sounder fault.Key FeaturesTwo wire serial connectionUp to 7 sounder boards per system230V AC or 24V DC powered versionsZoned 2-stage or common alarmAll outputs monitored for open and short circuit faultsIndividual open and short circuit fault indicatorsFully monitored by main control panelClass change input facilityUp to 8 outputs with 0.5A available from eachCan be connected to serial bus with Ancillary boards and repeatersBoxed units in enclosure to match Sigma CP control panelsPower fault input for monitoring remote power suppliesProduct CodesDescriptionK461Sigma CP Sounder PCBK04000M2Boxed Sigma CP Sounder PCBK04400M2Boxed Sigma CP Sounder PCB with 5.25 Amp PSU GBP 175.58 1
Kentec K27102 Fire Alarm Do Not Enter - Red On Black Kentec K27102 Fire Alarm Do Not Enter - Red On BlackThe new range of illuminated warning signs employ the very latest in LED technology to provide a high reliability high brightness audio visual warning indication unit.The brightness of the sign remains constant over its entire operating range of 15 to 30 volts DC due to the unique power boost circuitry employed. This ensures that even with a system running on depleted batteries all signs remain at full intensity.A range of standard text signs are available and customised text and languages are easily accommodated due to the unique method employed to apply the lettering.The split level design allows one message to be displayed in the top half of the sign and an additional message to be displayed in the bottom half of the sign allowing for two stage warnings for systems such as extinguishing protection systems.Key FeaturesRed text on a black backgroundFire Alarm Do Not Enter textHigh brightness white LED indicators for reliability and low power consumptionSplit level function - allows top half and bottom half of sign to be illuminated independently with no light spillage between halvesConnects to standard fire alarm sounder circuitsTwo wire 2 - stage top half bottom half voltage reversing input provided GBP 176.26 1
Kentec K21084M4 Sigma XT 8 Zone 4 Area Extinguishing Control Panel 8 Zone Conventional Kentec K21084M4 Sigma XT 8 Zone 4 Area Extinguishing Control Panel 8 Zone ConventionalSigma XT control panels are multi-area extinguishantcontrol panels complying with EN12094-1 EN54-2 and EN54-4. Up to 8 zones ofconventional detection with up to 4 extinguishant areas are available.Standalone extinguishant control units are also availablewith 2 monitored inputs to receive initiating signals from remote firedetection control panels or addressable modules.Each Extinguishant area has a comprehensive set of inputsand outputs and is configurable via a simple programming interface. Allextinguishant areas may have up to 7 serially connected Sigma SI statusindication and control units or ancillary relay boards connected via a simple 4core cable. The versatility of the control panel can be enhanced further by thefitting of up to 7 Sigma CP Ancillary boards K580 or Sigma CP Sounder boards.Key FeaturesApproved to EN12094-1 EN54-2 and EN54-42 4 or 8 detection zones1 to 4 extinguishant areasDual extinguishant outputs for each area configurable as MainReserveFirst and second stage sounder outputs for each areaFirst and second stage volt free changeover contacts for each areaReleased volt free contact per areaFault volt free contact per areaProgrammable extinguishant delaysProgrammable output durationExtract fan controlCountdown indicator shows time until release in secondsMode select and manual release controls per areaMonitored remote manual release inputMonitored remote Hold inputMonitored remote Mode select door interlock inputMonitored remote Released pressure switch inputMonitored remote Low Pressure switch inputMonitored Abort input GBP 2019.97 1
Kentec K27101 Fire Alarm Evacuate Area - Red on Black Kentec K27101 Fire Alarm Evacuate Area - Red on BlackThe new range of illuminated warning signs employ the verylatest in LED technology to provide a high reliability high brightness audiovisual warning indication unit.The brightness of the sign remains constant over its entireoperating range of 15 to 30 volts DC due to the unique power boost circuitryemployed. This ensures that even with a system running on depleted batteriesall signs remain at full intensity.A range of standard text signs are available and customisedtext and languages are easily accommodated due to the unique method employed toapply the lettering.The split-level design allows one message to be displayed inthe top half of the sign and an additional message to be displayed in thebottom half of the sign allowing for two stage warnings for systems such asextinguishing protection systems.The signs are now also available in splitcolours. Red green or yellow acrylic can be mounted in the top section and thebottom section in any configuration. Text can be printed in black oralternatively can be reversed so the letters appear in the colour of theacrylic.Key FeaturesColour Red on BlackHigh brightness white LED indicators for reliability and lowpower consumptionStandard or easily customisable wording and languagevariantsSplit level function - allows top half and bottom half ofsign to be illuminated independently with no light spillage between halvesInternal buzzer with disable and external silence facilityConnects to standard fire alarm sounder circuitsTwo wire 2 - stage top half bottom half voltage reversinginput providedVoltage reversing silenceable sounder output provided GBP 176.26 1
Kentec K27202 Extinguishant System Activated Sign - Black On Yellow Kentec K27202 Extinguishant System Activated Sign - Black On YellowThe new range of illuminated warning signs employ the verylatest in LED technology to provide a high reliability high brightness audiovisual warning indication unit.The brightness of the sign remains constant over its entireoperating range of 15 to 30 volts DC due to the unique power boost circuitryemployed. This ensures that even with a system running on depleted batteriesall signs remain at full intensity.A range of standard text signs are available and customisedtext and languages are easily accommodated due to the unique method employed toapply the lettering.The split-level design allows one message to be displayed inthe top half of the sign and an additional message to be displayed in thebottom half of the sign allowing for two stage warnings for systems such asextinguishing protection systems.The signs are now also available in split colours. Redgreen or yellow acrylic can be mounted in the top section and the bottomsection in any configuration. Text can be printed in black or alternatively canbe reversed so the letters appear in the colour of the acrylic.Key FeaturesColour Black on YellowHigh brightness white LED indicators for reliability and lowpower consumptionStandard or easily customisable wording and languagevariantsSplit level function - allows top half and bottom half ofsign to be illuminated independently with no light spillage between halvesInternal buzzer with disable and external silence facilityConnects to standard fire alarm sounder circuitsTwo wire 2 - stage top half bottom half voltage reversinginput providedVoltage reversing silenceable sounder output provided GBP 176.26 1
Kentec WX2710 Weatherproof Special Designation Specify Text Red on Black Kentec WX2710 Weatherproof Special Designation Specify Text Red on BlackThe new range of illuminated warning signs employ the very latest in LED technology to provide a high reliability high brightness audio visual warning indication unit.The brightness of the sign remains constant over its entire operating range of 15 to 30 volts DC due to the unique power boost circuitry employed. This ensures that even with a system running on depleted batteries all signs remain at full intensity.A range of standard text signs are available and customised text and languages are easily accommodated due to the unique method employed to apply the lettering.The split-level design allows one message to be displayed in the top half of the sign and an additional message to be displayed in the bottom half of the sign allowing for two stage warnings for systems such as extinguishing protection systems.The signs are now also available in split colours. Red green or yellow acrylic can be mounted in the top section and the bottom section in any configuration.Text can be printed in black or alternatively can be reversed so the letters appear in the colour of the acrylic.Key FeaturesHigh brightness white LED indicators for reliability and low power consumptionStandard or easily customisable wording and language variantsSplit level function - allows top half and bottom half of sign to be illuminated independently with no light spillage between halvesInternal buzzer with disable and external silence facilityConnects to standard fire alarm sounder circuitsTwo wire 2 - stage top half bottom half voltage reversing input providedVoltage reversing silenceable sounder output providedWeatherproof GBP 308.03 1
Kentec WX2730 Weatherproof Special Designation Specify Text Black on Green Kentec WX2730 Weatherproof Special Designation Specify Text Black on GreenThe new range of illuminated warning signs employ the very latest in LED technology to provide a high reliability high brightness audio visual warning indication unit.The brightness of the sign remains constant over its entire operating range of 15 to 30 volts DC due to the unique power boost circuitry employed. This ensures that even with a system running on depleted batteries all signs remain at full intensity.A range of standard text signs are available and customised text and languages are easily accommodated due to the unique method employed to apply the lettering.The split-level design allows one message to be displayed in the top half of the sign and an additional message to be displayed in the bottom half of the sign allowing for two stage warnings for systems such as extinguishing protection systems.The signs are now also available in split colours. Red green or yellow acrylic can be mounted in the top section and the bottom section in any configuration.Text can be printed in black or alternatively can be reversed so the letters appear in the colour of the acrylic.Key FeaturesHigh brightness white LED indicators for reliability and low power consumptionStandard or easily customisable wording and language variantsSplit level function - allows top half and bottom half of sign to be illuminated independently with no light spillage between halvesInternal buzzer with disable and external silence facilityConnects to standard fire alarm sounder circuitsTwo wire 2 - stage top half bottom half voltage reversing input providedVoltage reversing silenceable sounder output providedWeatherproof GBP 308.03 1
Kentec WX2720 Weatherproof Special Designation Specify Text Black on Yellow Kentec WX2720 Weatherproof Special Designation Specify Text Black on YellowThe new range of illuminated warning signs employ the very latest in LED technology to provide a high reliability high brightness audio visual warning indication unit.The brightness of the sign remains constant over its entire operating range of 15 to 30 volts DC due to the unique power boost circuitry employed. This ensures that even with a system running on depleted batteries all signs remain at full intensity.A range of standard text signs are available and customised text and languages are easily accommodated due to the unique method employed to apply the lettering.The split-level design allows one message to be displayed in the top half of the sign and an additional message to be displayed in the bottom half of the sign allowing for two stage warnings for systems such as extinguishing protection systems.The signs are now also available in split colours. Red green or yellow acrylic can be mounted in the top section and the bottom section in any configuration.Text can be printed in black or alternatively can be reversed so the letters appear in the colour of the acrylic.Key FeaturesHigh brightness white LED indicators for reliability and low power consumptionStandard or easily customisable wording and language variantsSplit level function - allows top half and bottom half of sign to be illuminated independently with no light spillage between halvesInternal buzzer with disable and external silence facilityConnects to standard fire alarm sounder circuitsTwo wire 2 - stage top half bottom half voltage reversing input providedVoltage reversing silenceable sounder output providedWeatherproof GBP 308.03 1
Kentec K21041M3 Sigma XT 4 Zone 1 Single Area Extinguishing Control Panel Kentec K21041M3 Sigma XT 4 Zone 1 Single Area Extinguishing Control PanelSigma XT control panels are multi-area extinguishant control panels complying with EN12094-1 EN54-2 and EN54-4. Up to 8 zones of conventional detection with up to 4 extinguishant areas are available. Stand-alone extinguishant control units are also available with 2 monitored inputs to receive initiating signals from remote fire detection control panels or addressable modules. Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via a simple programming interface.All extinguishant areas may have up to 7 serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple 4 core cable. The versatility of the control panel can be enhanced further by the fitting of up to 7 Sigma CP Ancillary boards K580 or Sigma CP Sounder boards K461 to the RS485 serial bus. See data sheet DS39 and DS48. For compatible status units see Sigma Si data sheet DS41.Key FeaturesApproved to EN12094-1 EN54-2 and EN54-42 4 or 8 detection zones1 to 4 extinguishant areasDual extinguishant outputs for each area configurable as MainReserveFirst and second stage sounder outputs for each areaFirst and second stage volt free changeover contacts for each areaReleased volt free contact per areaFault volt free contact per areaProgrammable extinguishant delaysProgrammable output durationExtract fan controlCountdown indicator shows time until release in secondsMode select and manual release controls per areaMonitored remote manual release inputMonitored remote Hold inputMonitored remote Mode select door interlock inputMonitored remote Released pressure switch inputMonitored remote Low Pressure switch inputMonitored Abort inputSerial connection for Sigma Si status units and ancillary boardsExtinguishing controls and status indicatorsDual action manual extinguishing release controlAutoManual keyswitchIntegral 3 Amp power supply 230V AC input GBP 804.47 1
Kentec K21083M4 Sigma XT 8 Zone 3 Area Extinguishing Control Panel Kentec K21083M4 Sigma XT 8 Zone 3 Area Extinguishing Control PanelSigma XT control panels are multi-area extinguishant control panels complying with EN12094-1 EN54-2 and EN54-4. Up to 8 zones of conventional detection with up to 4 extinguishant areas are available. Stand-alone extinguishant control units are also available with 2 monitored inputs to receive initiating signals from remote fire detection control panels or addressable modules. Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via a simple programming interface.All extinguishant areas may have up to 7 serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple 4 core cable. The versatility of the control panel can be enhanced further by the fitting of up to 7 Sigma CP Ancillary boards K580 or Sigma CP Sounder boards K461 to the RS485 serial bus. See data sheet DS39 and DS48. For compatible status units see Sigma Si data sheet DS41.Key Features Approved to EN12094-1 EN54-2 and EN54-4 2 4 or 8 detection zones 1 to 4 extinguishant areas Dual extinguishant outputs for each area configurable as MainReserve First and second stage sounder outputs for each area First and second stage volt free changeover contacts for each area Released volt free contact per area Fault volt free contact per area Programmable extinguishant delays Programmable output duration Extract fan control Countdown indicator shows time until release in seconds Mode select and manual release controls per area Monitored remote manual release input Monitored remote Hold input Monitored remote Mode select door interlock input Monitored remote Released pressure switch input Monitored remote Low Pressure switch input Monitored Abort input Serial connection for Sigma Si status units and ancillary boards Dual action manual extinguishing release control AutoManual keyswitch 3 Amp power supply 230V AC input GBP 1667.65 1
Kentec WK27202 Weatherproof Version Extinguishant System Activated - Black On Yellow Kentec WK27202 Weatherproof Version Extinguishant System Activated - Black On YellowThe new range of illuminated warning signs employ the very latest in LED technology to provide a high reliability high brightness audio visual warning indication unit.The brightness of the sign remains constant over its entire operating range of 15 to 30 volts DC due to the unique power boost circuitry employed.This ensures that even with a system running on depleted batteries all signs remain at full intensity.A range of standard text signs are available and customised text and languages are easily accommodated due to the unique method employed to apply the lettering.The split level design allows one message to be displayed in the top half of the sign and an additional message to be displayed in the bottom half of the sign allowing for two stage warnings for systems such as extinguishing protection systems.Key FeaturesText Extinguishant System ActivatedColour Black on yellow GBP 343.13 1
Kentec K21081M3 Sigma XT 8 Zone 1 Single Area Extinguishing Control Panel Kentec K21081M3 Sigma XT 8 Zone 1 Single Area Extinguishing Control PanelSigma XT control panels are multi-area extinguishant control panels complying with EN12094-1 EN54-2 and EN54-4. Up to 8 zones of conventional detection with up to 4 extinguishant areas are available. Stand-alone extinguishant control units are also available with 2 monitored inputs to receive initiating signals from remote fire detection control panels or addressable modules. Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via a simple programming interface.All extinguishant areas may have up to 7 serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple 4 core cable. The versatility of the control panel can be enhanced further by the fitting of up to 7 Sigma CP Ancillary boards K580 or Sigma CP Sounder boards K461 to the RS485 serial bus. See data sheet DS39 and DS48. For compatible status units see Sigma Si data sheet DS41.Key Features Approved to EN12094-1 EN54-2 and EN54-4 2 4 or 8 detection zones 1 to 4 extinguishant areas Dual extinguishant outputs for each area configurable as MainReserve First and second stage sounder outputs for each area First and second stage volt free changeover contacts for each area Released volt free contact per area Fault volt free contact per area Programmable extinguishant delays Programmable output duration Extract fan control Countdown indicator shows time until release in seconds Mode select and manual release controls per area Monitored remote manual release input Monitored remote Hold input Monitored remote Mode select door interlock input Monitored remote Released pressure switch input Monitored remote Low Pressure switch input Monitored Abort input Serial connection for Sigma Si status units and ancillary boards Extinguishing controls and status indicators Dual action manual extinguishing release control AutoManual keyswitch Integral 3 Amp power supply 230V AC input GBP 1174.42 1
Kentec K21082M3 Sigma XT 8 Zone 2 Area Extinguishing Control Panel Kentec K21082M3 Sigma XT 8 Zone 2 Area Extinguishing Control PanelSigma XT control panels are multi-area extinguishant control panels complying with EN12094-1 EN54-2 and EN54-4. Up to 8 zones of conventional detection with up to 4 extinguishant areas are available. Stand-alone extinguishant control units are also available with 2 monitored inputs to receive initiating signals from remote fire detection control panels or addressable modules. Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via a simple programming interface.All extinguishant areas may have up to 7 serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple 4 core cable. The versatility of the control panel can be enhanced further by the fitting of up to 7 Sigma CP Ancillary boards K580 or Sigma CP Sounder boards K461 to the RS485 serial bus. See data sheet DS39 and DS48. For compatible status units see Sigma Si data sheet DS41.Key Features Approved to EN12094-1 EN54-2 and EN54-4 2 4 or 8 detection zones 1 to 4 extinguishant areas Dual extinguishant outputs for each area configurable as MainReserve First and second stage sounder outputs for each area First and second stage volt free changeover contacts for each area Released volt free contact per area Fault volt free contact per area Programmable extinguishant delays Programmable output duration Extract fan control Countdown indicator shows time until release in seconds Mode select and manual release controls per area Monitored remote manual release input Monitored remote Hold input Monitored remote Mode select door interlock input Monitored remote Released pressure switch input Monitored remote Low Pressure switch input Monitored Abort input Serial connection for Sigma Si status units and ancillary boards Extinguishing controls and status indicators Dual action manual extinguishing release control AutoManual keyswitch Integral 3 Amp power supply 230V AC input GBP 1350.56 1
Kentec K21042M3 Sigma XT 4 Zone 2 Area Extinguishing Control Panel Kentec K21042M3 Sigma XT 4 Zone 2 Area Extinguishing Control PanelSigma XT control panels are multi-area extinguishant control panels complying with EN12094-1 EN54-2 and EN54-4. Up to 8 zones of conventional detection with up to 4 extinguishant areas are available. Stand-alone extinguishant control units are also available with 2 monitored inputs to receive initiating signals from remote fire detection control panels or addressable modules. Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via a simple programming interface.All extinguishant areas may have up to 7 serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple 4 core cable. The versatility of the control panel can be enhanced further by the fitting of up to 7 Sigma CP Ancillary boards K580 or Sigma CP Sounder boards K461 to the RS485 serial bus. See data sheet DS39 and DS48. For compatible status units see Sigma Si data sheet DS41.Key Features Approved to EN12094-1 EN54-2 and EN54-4 2 4 or 8 detection zones 1 to 4 extinguishant areas Dual extinguishant outputs for each area configurable as MainReserve First and second stage sounder outputs for each area First and second stage volt free changeover contacts for each area Released volt free contact per area Fault volt free contact per area Programmable extinguishant delays Programmable output duration Extract fan control Countdown indicator shows time until release in seconds Mode select and manual release controls per area Monitored remote manual release input Monitored remote Hold input Monitored remote Mode select door interlock input Monitored remote Released pressure switch input Monitored remote Low Pressure switch input Monitored Abort input Serial connection for Sigma Si status units and ancillary boards Extinguishing controls and status indicators Dual action manual extinguishing release control AutoManual keyswitch Integral 3 Amp power supply 230V AC input GBP 1274.23 1
Kentec K04000M2 Sigma CP Sounder PCB - Boxed Kentec K04000M2 Sigma CP Sounder PCB - BoxedThe Sigma K04000M2 is a sounder controller PCB in a steel enclosure which requires a 24v DC power source.The Kentec Sigma CP Sounder Board is compatible with all Sigma CP control panels which have operating software version V3.0 or above.The board provides 8 additional sounder outputs which can be configured as zoned 2-stage or common alarm.All sounder outputs are open and short circuit monitored and any faults on the sounder outputs will be announced at the main fire alarm panel as a sounder fault.A class change input is provided which when activated by a volt free contact closing will switch all sounder outputs on.Mains powered units require only a two core data cable from the main control panel. 24V DC versions require an additional two cores from another 24V DC source which is suitably rated to supply the total sounder current. 230V versions have their own power supply which is rated to supply sounder loads up to 5.25 Amps.Up to 7 Sounder boards can be connected to a control panel and each is allocated an address from 1 to 7 using a binary coded DIL switch. Sounder boards may be connected to the Sigma CP serial bus in addition to Sigma CP ancillary boards and Sigma CP-R repeater panels.The total length of the data cable from the main panel to the last repeater must not exceed 1200 metres. Once Sounder boards have been recognised by the main panel a fault will be announced at the main panel if any become disconnected.Key FeaturesTwo wire serial connectionUp to 7 sounder boards per system24V DC powered - in steel enclosureZoned 2-stage or common alarmAll outputs monitored for open and short circuit faultsIndividual open and short circuit fault indicatorsFully monitored by main control panelClass change input facilityUp to 8 outputs with 1A available from eachCan be connected to serial bus with Ancillary boards and repeatersPower fault input for monitoring remote power supplies GBP 246.64 1
Kentec K04400M2 Sigma CP Sounder PCB - Boxed Kentec K04400M2 Sigma CP Sounder PCB - BoxedThe Sigma K04400M2 is a sounder controller PCB in a steel enclosure which requires a 230V DC power source.The Kentec Sigma CP Sounder Board is compatible with all Sigma CP control panels which have operating software version V3.0 or above.The board provides 8 additional sounder outputs which can be configured as zoned 2-stage or common alarm.All sounder outputs are open and short circuit monitored and any faults on the sounder outputs will be announced at the main fire alarm panel as a sounder fault.A class change input is provided which when activated by a volt free contact closing will switch all sounder outputs on.Mains powered units require only a two core data cable from the main control panel. 24V DC versions require an additional two cores from another 24V DC source which is suitably rated to supply the total sounder current. 230V versions have their own power supply which is rated to supply sounder loads up to 5.25 Amps.Up to 7 Sounder boards can be connected to a control panel and each is allocated an address from 1 to 7 using a binary coded DIL switch. Sounder boards may be connected to the Sigma CP serial bus in addition to Sigma CP ancillary boards and Sigma CP-R repeater panels.The total length of the data cable from the main panel to the last repeater must not exceed 1200 metres. Once Sounder boards have been recognised by the main panel a fault will be announced at the main panel if any become disconnected.Key FeaturesTwo wire serial connectionUp to 7 sounder boards per system24V DC powered - in steel enclosureZoned 2-stage or common alarmAll outputs monitored for open and short circuit faultsIndividual open and short circuit fault indicatorsFully monitored by main control panelClass change input facilityUp to 8 outputs with 1A available from eachCan be connected to serial bus with Ancillary boards and repeatersPower fault input for monitoring remote power supplies GBP 522.61 1
Kentec WK27101 Weatherproof Version Fire Alarm Evacuate Area - Red on Black Kentec WK27101 Weatherproof Version Fire Alarm Evacuate Area - Red on BlackThe new range of illuminated warning signs employ the very latest in LED technology to provide a high reliability high brightness audio visual warning indication unit.The brightness of the sign remains constant over its entire operating range of 15 to 30 volts DC due to the unique power boost circuitry employed.This ensures that even with a system running on depleted batteries all signs remain at full intensity.A range of standard text signs are available and customised text and languages are easily accommodated due to the unique method employed to apply the lettering.The split level design allows one message to be displayed in the top half of the sign and an additional message to be displayed in the bottom half of the sign allowing for two stage warnings for systems such as extinguishing protection systems.Key FeaturesText Fire Alarm Evacuate AreaColour Red on Black GBP 343.13 1
Kentec WK27102 Weatherproof Version Fire Alarm Do Not Enter - Red on Black Kentec WK27102 Weatherproof Version Fire Alarm Do Not Enter - Red on BlackThe new range of illuminated warning signs employ the very latest in LED technology to provide a high reliability high brightness audio visual warning indication unit.The brightness of the sign remains constant over its entire operating range of 15 to 30 volts DC due to the unique power boost circuitry employed.This ensures that even with a system running on depleted batteries all signs remain at full intensity.A range of standard text signs are available and customised text and languages are easily accommodated due to the unique method employed to apply the lettering.The split level design allows one message to be displayed in the top half of the sign and an additional message to be displayed in the bottom half of the sign allowing for two stage warnings for systems such as extinguishing protection systems.Key FeaturesText Fire Alarm Do Not EnterColour Red on Black GBP 343.13 1
Kentec Sigma XT Extinguishant Control Panel to BS EN12094-1 2 - 8 Zone Kentec Sigma XT Extinguishant Control Panel to BS EN12094-1 2 - 8 ZoneSigma XT control panels are multi-area extinguishant control panels complying with EN12094-1 EN54-2 and EN54-4. Up to 8 zones of conventional detection with up to 4 extinguishant areas are available. Stand-alone extinguishant control units are also available with 2 monitored inputs to receive initiating signals from remote fire detection control panels or addressable modules. Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via a simple programming interface.All extinguishant areas may have up to 7 serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple 4 core cable. The versatility of the control panel can be enhanced further by the fitting of up to 7 Sigma CP Ancillary boards K580 or Sigma CP Sounder boards K461 to the RS485 serial bus. See data sheet DS39 and DS48. For compatible status units see Sigma Si data sheet DS41.Key FeaturesApproved to EN12094-1 EN54-2 and EN54-42 4 or 8 detection zones1 to 4 extinguishant areasDual extinguishant outputs for each area configurable as MainReserveFirst and second stage sounder outputs for each areaFirst and second stage volt free changeover contacts for each areaReleased volt free contact per areaFault volt free contact per areaProgrammable extinguishant delaysProgrammable output durationExtract fan controlCountdown indicator shows time until release in secondsMode select and manual release controls per areaMonitored remote manual release inputMonitored remote Hold inputMonitored remote Mode select door interlock inputMonitored remote Released pressure switch inputMonitored remote Low Pressure switch inputMonitored Abort inputSerial connection for Sigma Si status units and ancillary boards. K588Part NumberDescriptionK21021M3Sigma XT 2 Zone Extinguishant Control Panel 1 Area SurfaceK21041M3Sigma XT 4 Zone Extinguishant Control Panel 1 Area SurfaceK21042M3Sigma XT 4 Zone Extinguishant Control Panel 2 Area SurfaceK21081M3Sigma XT 8 Zone Extinguishant Control Panel 1 Area SurfaceK21082M3Sigma XT 8 Zone Extinguishant Control Panel 2 Area SurfaceK21083M4Sigma XT 8 Zone Extinguishant Control Panel 3 Area Surface larger PSU 5.25AK21084M4Sigma XT 8 Zone Extinguishant Control Panel 4 Area Surface larger PSU 5.25A GBP 734.00 1
Kentec Sigma XT Extinguishant Coincidence Unit 1 Area to EN12094-1 Surface Kentec Sigma XT Extinguishant Coincidence Unit 1 Area to EN12094-1 SurfaceThe Sigma XT ECU coincidence unit has two fully monitored inputs for connection to fire detection control equipment or addressable control modules to provide an EN12094-1 EN54-2 and EN54-4compliant extinguishant control system. Its many programmable features and extensive range of inputs and outputs make the Sigma XT ECU coincidence unit suitable for all extinguishing applications where a fully featured control device is required.Among the many features of the Sigma XT ECU are serially connected status units for reduced wiring and reduced installation cost dual extinguishant outputs that may be configured for mainreserve applications and a countdown timer which displays the time until discharge of the extinguishant in seconds. All units are independently configurable via a simple code based programming interface to suit the desired application.Key FeaturesApproved to EN12094-1 EN54-2 and EN54-4Dual extinguishant outputsFirst and second stage sounder outputsFirst and second stages relay contactsMain reserve facilitySerial connection to status unitsDischarge countdown time indicator GBP 616.56 1
Kentec Sigma CP 2 Zone Conventional Fire Alarm Panel K11020M2 Kentec Sigma CP2 Zone Conventional Fire Alarm PanelThe Sigma CP range consists of a series of conventional fire alarm control panels designed in accordance with European standards BS EN54-2 and BS EN54-4 Fire Detection and Fire Alarm systems - Control and Indicating Equipment. The range consists of 2 4 and 8 zone control panels.All control panels are available in two versionsSigma K11 range in which detectors and call points are wired on separate circuits to sounders two sounder circuits are provided.Sigma T11 range in which detectors call points and sounders are wired to the same pair of cables. Commonly referred to as a two-wire system.Wiring sounders to the detection circuits eliminates the need to install sounder circuit cables and also offers the ability to provide zoned or two stage sounder operation. T series only All control panels have an integral mains powered battery charger and power supply designed in accordance with the requirements of BS EN54-4.Key FeaturesFully certified to BS EN54-2 and BS EN54-42-wire and standard versions in 2 4 or 8 zonesCompatible for use on BS5839 Part 1 2002 installations2-wire repeaters and ancillary boardsFully programmable using simple menu optionsAdjustable sounder delay timeSounder configuration optionsZonal sounder delay detectors onlyZonal sounder delay call points onlyCoincidence input selectionI.S Barrier selection by zoneShort circuit fire by zoneNon latching zonesSilent zonesZone input delayGeneral panel configurationSimple single board constructionInstaller friendlyCompatible with wide range of detection devicesTwo monitored sounder outputs3 Amp power supplyAuxiliary power output GBP 300.32 1
Kentec Sigma CP 8 Zone Conventional Fire Alarm Panel K11080M2 Kentec Sigma CP 8 Zone Conventional Fire Alarm Panel K11080M2The Sigma CP range consists of a series of conventional fire alarm control panels designed in accordance with European standards BS EN54-2 and BS EN54-4 Fire Detection and Fire Alarm systems - Control and Indicating Equipment. The range consists of 2 4 and 8 zone control panels.All control panels are available in two versionsSigma K11range in which detectors and call points are wired on separate circuits to sounders two sounder circuits are provided.Sigma T11range in which detectors call points and sounders are wired to the same pair of cables. Commonly referred to as a two-wire system.Wiring sounders to the detection circuits eliminates the need to install sounder circuit cables and also offers the ability to provide zoned or two stage sounder operation. T series only All control panels have an integral mains powered battery charger and power supply designed in accordance with the requirements of BS EN54-4.Key FeaturesFully certified to BS EN54-2 and BS EN54-42-wire and standard versions in 2 4 or 8 zonesCompatible for use on BS5839 Part 1 2002 installations2-wire repeaters and ancillary boardsSimple single board constructionInstaller friendlyCompatible with wide range of detection devicesTwo monitored sounder outputs3 Amp power supplyAuxiliary power outputFully programmable using simple menu optionsAdjustable sounder delay timeSounder configuration optionsZonal sounder delay detectors onlyZonal sounder delay call points onlyCoincidence input selectionI.S Barrier selection by zoneShort circuit fire by zoneNon latching zonesSilent zonesZone input delayGeneral panel configuration GBP 361.14 1
Kentec Sigma CP 4 Zone Conventional Fire Alarm Panel K11040M2 Kentec Sigma CP 4 Zone Conventional Fire Alarm PanelK11040M2The Sigma CP range consists of a series of conventional fire alarm control panels designed in accordance with European standards BS EN54-2 and BS EN54-4 Fire Detection and Fire Alarm systems - Control and Indicating Equipment. The range consists of 2 4 and 8 zone control panels.All control panels are available in two versionsSigma K11range in which detectors and call points are wired on separate circuits to sounders two sounder circuits are provided.Sigma T11range in which detectors call points and sounders are wired to the same pair of cables. Commonly referred to as a two-wire system.Wiring sounders to the detection circuits eliminates the need to install sounder circuit cables and also offers the ability to provide zoned or two stage sounder operation. T series only All control panels have an integral mains powered battery charger and power supply designed in accordance with the requirements of BS EN54-4.Key FeaturesFully certified to BS EN54-2 and BS EN54-42-wire and standard versions in 2 4 or 8 zonesCompatible for use on BS5839 Part 1 2002 installations2-wire repeaters and ancillary boardsSimple single board constructionInstaller friendlyCompatible with wide range of detection devicesTwo monitored sounder outputs3 Amp power supplyAuxiliary power outputFully programmable using simple menu optionsAdjustable sounder delay timeSounder configuration optionsZonal sounder delay detectors onlyZonal sounder delay call points onlyCoincidence input selectionI.S Barrier selection by zoneShort circuit fire by zoneNon latching zonesSilent zonesZone input delayGeneral panel configuration GBP 318.37 1
Kentec K1810-43 Sigma A-XT Extinguishant Control Panel - 230V Grey Kentec K1810-43 Sigma A-XT Extinguishant Control Panel - 230V GreySigma A-XT releasing panel offers outstanding value and performance for all small to medium fixed fire-fighting installations.With three initiating circuits as standard release can be configured to activate from any combination of detection zone inputs to allow among other combinations any two from three types of activations for detection in ceiling void room and floor void applications.The extensive configuration options of the Sigma A-XT allow the functionality of the system to be extensively modified. The panel contains a large LED display to enable easy configuration and control which also displays the time remaining until release for added user safety.The countdown time is duplicated on up to seven remote status units to provide local indication of the system status.With all the electronics mounted on a single easily removable steel plate Sigma A-XT panels are both robust and easy to install. Sigma A-XT is supplied in an enclosure that matches the design and colour of the Elite RS range and is available in standard red or optional grey.The K16400M2 from the extensive range of Kentec products is a syncro IO expansion card enclosure with 5.25A power supply. flexibility to create customised IO panel.Key FeaturesUL864 and FM ListedThree initiation circuits as standardAny single zone or any combinations of zones can be configured to releaseConfigurable first stage NAC delaysConfigurable detection delaysZero time delay upon manual release optionSupports up to seven four wire status indicatorsBuilt in Extract Fan controlCompatible with I.S. barriersNon-latching zone input option to receive signals from other systems such as aspirating equipmentConfigurable releasing delays up to 60 seconds in 5 second stopsConfigurable releasing duration up to 5 minutes in 5 second stepsCountdown timer shows time remaining until release GBP 628.31 1
Kentec K1810-13 Sigma A-XT Extinguishant Control Panel - 230V Red Kentec K1810-13 Sigma A-XT Extinguishant Control Panel - 230V RedSigma A-XT releasing panel offers outstanding value and performance for all small to medium fixed fire-fighting installations.With three initiating circuits as standard release can be configured to activate from any combination of detection zone inputs to allow among other combinations any two from three types of activations for detection in ceiling void room and floor void applications.The extensive configuration options of the Sigma A-XT allow the functionality of the system to be extensively modified. The panel contains a large LED display to enable easy configuration and control which also displays the time remaining until release for added user safety.The countdown time is duplicated on up to seven remote status units to provide local indication of the system status.With all the electronics mounted on a single easily removable steel plate Sigma A-XT panels are both robust and easy to install. Sigma A-XT is supplied in an enclosure that matches the design and colour of the Elite RS range and is available in standard red or optional grey.The K16400M2 from the extensive range of Kentec products is a syncro IO expansion card enclosure with 5.25A power supply. flexibility to create customised IO panel.Key FeaturesUL864 and FM ListedThree initiation circuits as standardAny single zone or any combinations of zones can be configured to releaseConfigurable first stage NAC delaysConfigurable detection delaysZero time delay upon manual release optionSupports up to seven four wire status indicatorsBuilt in Extract Fan controlCompatible with I.S. barriersNon-latching zone input option to receive signals from other systems such as aspirating equipmentConfigurable releasing delays up to 60 seconds in 5 second stopsConfigurable releasing duration up to 5 minutes in 5 second stepsCountdown timer shows time remaining until release GBP 628.31 1