C-Tec HEAD1 PDA 32 Ohm Headphones for FPRO C-Tec HEAD1 PDA 32 Ohm Headphones for FPROThe HEAD1 is a pair of PDA 32 Ohm Headphones designed for use with the FPRO PDA FoSmeter Afils Test Meter. GBP 39.86 1
C-Tec XFP510-32 XFP Repeater Panel 32 Zone C-Tec XFP510-32 XFP Repeater Panel 32 ZoneCan be used to repeat the functions of an XFP Main panel at remote parts of a site e.g. all potential fire service entrances. Offers all of the functions and controls of an XFP Main panel access levels 1 2 and 3. Includes an on-board fault relay. Requires its own dedicated Mains power and battery back-up supply.A maximum of eight XFP Repeaters can be connected to one non-networked XFP Main panel. Communication between the XFP Main panel and Repeater requires an AFP711 network driver card fitted as standard in all XFP510-32s available as an optional extra on Main XFP 32 Zone panels. Repeater network wired in 1.5 mm2 two-core screened fire resistant cable. Network length must not exceed 500 metres.Key FeaturesCan be used to repeat the functions of an XFP Main panel at remote parts of a site e.g. all potential fire service entrances.Offers all of the functions and controls of an XFP Main panel access levels 1 2 and 3.Includes an on-board fault relay.Requires its own dedicated Mains power and battery back-up supply.A maximum of eight XFP Repeaters can be connected to one non-networked XFP Main panel.Communication between the XFP Main panel and Repeater requires an AFP711 network driver card fitted as standard in all XFP510-32s available as an optional extra on Main XFP 32 Zone panels.Repeater network is non-redundant and wired in 1.5 mm2 two-core screened fire resistant cable. Network length must not exceed 500 metres. GBP 433.36 1
C-Tec XFP502H XFP Addressable Two Loop 32 Zone Panel - Hochiki Protocol C-Tec XFP502H XFP Addressable Two Loop 32 Zone Panel - Hochiki ProtocolC-TECs XFP two loop 32 zone addressable fire alarm panel offers high performance at a very competitive price.LPCB certified to EN54 parts 2 4 it is supplied in durable metal enclosure offers combined keypad or keyswitch entry to Access Levels 2 and 3 and is compatible with Hochikis ESP protocol.Ideal for use in small stand-alone applications or in larger applications due to its ability to sit on network of up to 8 XFP master panels it is one of Europes best-selling addressable fire panels.Packed full of engineering features please refer to the feature list below the XFP502H is also fully compatible with C-TECs Hush Button fire alarm solution.Key FeaturesThird-party certified to EN54-24 by the Loss Prevention Certification Board LPCB.Compatibility with Hochikis ESP protocol.Two independently programmable conventional sounder circuits.Two programmable inputs.A fault output relay and three programmable relay outputs with voltage free changeover contacts.A selection of zone dependencycoincidence functions.A daynight building occupiedunoccupied function.An investigation delay period function.Phased evacuation facility.An alarm counter that records how many times the panel has been in alarm state.Powerful short circuit protected loop drivers capable of supporting up to 40 loop powered 10mA sounders per loop.An integral EN54-4A2 switch mode power supply.Adjustable contamination levels.Earth fault monitoring.Combined keypad keyswitch entry to Access Levels 2 and 3.999 event monitoring.An intuitive Windows based upload-download PC program.Optional flush-mounting bezel and glazed stainless steel enclosure also available.Up to eight XFP main panels any variant can be connected onto a two-wire RS485 non-redundant network. Alternatively up to eight XFP repeaters can be connected to any non-networked main panel. GBP 796.78 1
C-Tec XFP501H XFP Addressable Single Loop 32 Zone Panel - Hochiki Protocol C-Tec XFP501H XFP Addressable Single Loop 32 Zone Panel - Hochiki ProtocolC-TECs XFP single loop 32 zoneaddressable fire alarm panel offers high performance at a very competitive price. LPCBcertified to EN54 parts 2 4 it is supplied in durable metal enclosure offers combined keypad or keyswitch entry to Access Levels 2 and 3 and is compatible with Apollos XP95Discovery protocol.Ideal for use in small stand-alone applications orin larger applications dueto its ability to sit on network of up to 8 XFP master panelsit is one of Europes best-selling addressable fire panels. Packed full of engineering features- please refer to the feature list below -the XFP501X is also fully compatible with C-TECs Hush Button fire alarm solution and its new range of EN54 certified addressable sounders and VADs.Key FeaturesThird-party certified to EN54-24 by the Loss Prevention Certification Board LPCB.Compatibility with Apollos XP95Discovery protocol.Two independently programmable conventional sounder circuits.Two programmable inputs.A fault output relay and three programmable relay outputs with voltage free changeover contacts.A selection of zone dependencycoincidence functions.A daynight building occupiedunoccupied function.An investigation delay period function.Phased evacuation facility.An alarm counter that records how many times the panel has been in alarm state.Powerful short circuit protected loop drivers capable of supporting up to 40 loop powered 10mA sounders per loop.An integral EN54-4A2 switch mode power supply.Adjustable contamination levels.Earth fault monitoring.Combined keypad keyswitch entry to Access Levels 2 and 3.999 event monitoring.An intuitive Windows based upload-download PC program.Optional flush-mounting bezel and glazed stainless steel enclosure also available.Up to eight XFP main panels any variant can be connected onto a two-wire RS485 network. Alternatively up to eight XFP repeaters can be connected to any non-networked main panel. GBP 633.78 1
C-Tec BF3593S Stainless Steel Glazed Enclosure C-Tec BF3593S Stainless Steel Glazed EnclosureAn attractive flush-mounting glazed stainless steel enclosure ideal for housing a number of C-TEC-manufactured control panels. Compatible products include XFP 1-2 loop 32 zone fire panels and Quantec controllers. It helps protect control equipment from unauthorised accesstamperingKey FeaturesHigh quality brushed stainless steel finishPicture shows a BF3593S enclosure with an XFP 1 Loop 32 Zone panel fittedTechnical InformationCompatibility Suitable for use with XFP 1-2 Loop 32 Zone Fire Panels QT601-2 Quantec Controllers ENU-8NT SigTel Controllers without handsetsDimensions mm 725W x 448H x 103D overall dimensions 650W x 370H mm back box 725H x 448H x 10D mm bezel. Flush mount depth for wall-mounting 93mm.Construction Polycarbonate front window Brushed stainless-steel door and bezel Mild steel back-box.Weight 9.3Kg GBP 566.82 1
C-TEC XFP502CA XFP 2 loop 32 Zone Panel C-TEC CAST. Max. 2 x 7Ah batteries C-TEC XFP502CA XFP 2 loop 32 Zone Panel C-TEC CAST. Max. 2 x 7Ah batteriesC-TECs tried and trusted XFP two loop 32 zoneaddressable fire alarm panel - now available with C-TECs own digital fire alarm system protocol CAST and fully certified to EN54 parts 2 4 13.With two powerful 40V 450mA loop drivers allowing the connection of up to 255 CAST devices per loop the installation of a robust feature-packed addressable fire alarm system has never been easier.Always thought of the XFP as an entry-level fire panel Think again. Thanks to CASTs multiple type codes high speed data transmission and two speedy soft addressing options automatic via the panel or manually via a handheld programmerdevice tester it is undoubtedly one of the most powerful two loop fire panels around. This and its ability to sit on a network of up to 8 XFP master panels makes it ideal for use in small to medium sized stand-alone applications and larger more sophisticated installations alike.Protocol FeaturesCAST is the worlds most-advanced distributed intelligence fire alarm system protocol. Conceived designed and realised by C-TEC as part of a five-year multi-million pound project it involved the creation of a powerful proprietary communication protocol C-TEC Addressable System Technology CAST and multiple control panels field devices. Key features include 255 devices per loop. Autonomous decision-making for faster response times. Multiple type codes. 40V loop drive voltage. Two soft addressing options automatic via the panel or manual via a powerful handheld programmer. Powerful multi-level addressing facilitates easy device addition and swapped device identification. Multiple functionality at a single address integrated devices - due 2021. Volumes tones detector modes can be changed at compatible panels. High-speed data transmission and robust data transfer. Provides geographical location of short and open circuit faults a short circuit isolator is included as standard in every CAST field device. Replace device function. Programmable multi-function status LED. Future seamless integration with other CAST life safety systems reducing energy servicing installation and repair costs. ENVISION Enabled - fully compliant with our new ENVISION Cloud-based Fire IoT Remote Access System Test and Site Management software package. Designed and manufactured in the UK.Panel Features Certifiedto EN54-24 by the Loss Prevention Certification Board LPCB and EN54-13 by Kiwa Telefication. Two independently programmable conventional sounder circuits. Two programmable inputs. A fault output relay and three programmable relay outputs with voltage free changeover contacts. A selection of zone dependencycoincidence functions. A daynight building occupiedunoccupied function. An investigation delay period function. Phased evacuation facility. An alarm counter that records how many times the panel has been in alarm state. Powerful short circuit protected loop drivers. An integral EN54-4A2 switch mode. Adjustable contamination levels. Earth fault monitoring. Combined keypad keyswitch entry to Access Levels 2 and 3. 500 event monitoring. An intuitive Windows based upload-download PC program. Up to eight XFP main panels any variant can be connected onto a two-wire RS485 non-redundantnetwork. Alternatively up to eight XFP repeaters can be connected to any non-networked main panel.Cast Commissioning Services available with this Equipment GBP 701.32 1
C-TEC XFP501CA XFP 1 loop 32 Zone Panel C-TEC CAST. Max. 2 x 7Ah Batteries C-TEC XFP501CA XFP 1 loop 32 Zone Panel C-TEC CAST. Max. 2 x 7Ah BatteriesC-TECs tried and trusted XFP oneloop 32 zoneaddressable fire alarm panel - now available with C-TECs own digital fire alarm system protocol CAST and fully certified to EN54 parts 2 4 and 13.With a powerful 40V 450mA loop driver allowing the connection of up to 255 CAST devices the installation of a robust feature-packed addressable fire alarm system has never been easier.Always thought of the XFP as an entry-level fire panel Think again. Thanks to CASTs multiple type codes high speed data transmission and two speedy soft addressing options automatic via the panel or manually via a handheld programmerdevice tester it is undoubtedly one of the most powerful one loop fire panels around. This and its ability to sit on a network of up to 8 XFP master panels makes it ideal for use in small to medium sized stand-alone applications and larger more sophisticated installations alike.Protocol FeaturesCAST is the worlds most-advanced distributed intelligence fire alarm system protocol. Conceived designed and realised by C-TEC as part of a five-year multi-million pound project it involved the creation of a powerful proprietary communication protocol C-TEC Addressable System Technology CAST and multiple control panels field devices.Key Features 255 devices per loop. Autonomous decision-making for faster response times. Multiple type codes. 40V loop drive voltage. Two soft addressing options automatic via the panel or manual via a powerful handheld programmer. Powerful multi-level addressing facilitates easy device addition and swapped device identification. Multiple functionality at a single address integrated devices - due 2021. Volumes tones detector modes can be changed at compatible panels. High-speed data transmission and robust data transfer. Provides geographical location of short and open circuit faults a short circuit isolator is included as standard in every CAST field device. Replace device function. Programmable multi-function status LED. Future seamless integration with other CAST life safety systems reducing energy servicing installation and repair costs. ENVISION Enabled - fully compliant with our new ENVISION Cloud-based Fire IoT Remote Access System Test and Site Management software package. Designed and manufactured in the UK.Panel Features Certifiedto EN54-24 by the Loss Prevention Certification Board LPCB and EN54-13 by Kiwa Telefication. Two independently programmable conventional sounder circuits. Two programmable inputs. A fault output relay and three programmable relay outputs with voltage free changeover contacts. A selection of zone dependencycoincidence functions. A daynight building occupiedunoccupied function. An investigation delay period function. Phased evacuation facility. An alarm counter that records how many times the panel has been in alarm state. Powerful short circuit protected loop drivers. An integral EN54-4A2 switch mode. Adjustable contamination levels. Earth fault monitoring. Combined keypad keyswitch entry to Access Levels 2 and 3. 500 event monitoring. An intuitive Windows based upload-download PC program. Up to eight XFP main panels any variant can be connected onto a two-wire RS485 non-redundantnetwork. Alternatively up to eight XFP repeaters can be connected to any non-networked main panel.Cast Commissioning Services available with this Equipment GBP 557.02 1
C-Tec XFP502X XFP Addressable Two Loop 32 Zone Panel - Apollo XP95 Discovery Protocol C-Tec XFP502X XFP Addressable Two Loop 32 Zone Panel - Apollo XP95 Discovery ProtocolC-TECs XFP two loop 32 zoneaddressable fire alarm panel offers high performance at a very competitive price. LPCBcertified to EN54 parts 2 4 it is supplied in durable metal enclosure offers combined keypad or keyswitch entry to Access Levels 2 and 3 and is compatible with Apollos XP95Discovery protocol.Ideal for use in small stand-alone applications orin larger applications dueto its ability to sit on network of up to 8 XFP master panelsit is one of Europes best-selling addressable fire panels. Packed full of engineering features- please refer to the feature list below -the XFP501X is also fully compatible with C-TECs Hush Button fire alarm solution and its new range of EN54 certified addressable sounders and VADs.Key FeaturesThird-party certified to EN54-24 by the Loss Prevention Certification Board LPCB.Compatibility with Apollos XP95Discovery protocol.Two independently programmable conventional sounder circuits.Two programmable inputs.A fault output relay and three programmable relay outputs with voltage free changeover contacts.A selection of zone dependencycoincidence functions.A daynight building occupiedunoccupied function.An investigation delay period function.Phased evacuation facility.An alarm counter that records how many times the panel has been in alarm state.Powerful short circuit protected loop drivers capable of supporting up to 40 loop powered 10mA sounders per loop.An integral EN54-4A2 switch mode power supply.Adjustable contamination levels.Earth fault monitoring.Combined keypad keyswitch entry to Access Levels 2 and 3.999 event monitoring.An intuitive Windows based upload-download PC program.Optional flush-mounting bezel and glazed stainless steel enclosure also available.Up to eight XFP main panels any variant can be connected onto a two-wire RS485 network. Alternatively up to eight XFP repeaters can be connected to any non-networked main panel. GBP 796.78 1
C-Tec XFP501X XFP Addressable Single Loop 32 Zone Panel - Apollo XP95 Discovery Protocol C-Tec XFP501X XFP Addressable Single Loop 32 Zone Panel - Apollo XP95 Discovery ProtocolC-TECs XFP single loop 32 zoneaddressable fire alarm panel offers high performance at a very competitive price. LPCBcertified to EN54 parts 2 4 it is supplied in durable metal enclosure offers combined keypad or keyswitch entry to Access Levels 2 and 3 and is compatible with Apollos XP95Discovery protocol.Ideal for use in small stand-alone applications orin larger applications dueto its ability to sit on network of up to 8 XFP master panelsit is one of Europes best-selling addressable fire panels. Packed full of engineering features- please refer to the feature list below -the XFP501X is also fully compatible with C-TECs Hush Button fire alarm solution and its new range of EN54 certified addressable sounders and VADs.Key FeaturesThird-party certified to EN54-24 by the Loss Prevention Certification Board LPCB.Compatibility with Apollos XP95Discovery protocol.Two independently programmable conventional sounder circuits.Two programmable inputs.A fault output relay and three programmable relay outputs with voltage free changeover contacts.A selection of zone dependencycoincidence functions.A daynight building occupiedunoccupied function.An investigation delay period function.Phased evacuation facility.An alarm counter that records how many times the panel has been in alarm state.Powerful short circuit protected loop drivers capable of supporting up to 40 loop powered 10mA sounders per loop.An integral EN54-4A2 switch mode power supply.Adjustable contamination levels.Earth fault monitoring.Combined keypad keyswitch entry to Access Levels 2 and 3.999 event monitoring.An intuitive Windows based upload-download PC program.Optional flush-mounting bezel and glazed stainless steel enclosure also available.Up to eight XFP main panels any variant can be connected onto a two-wire RS485 network. Alternatively up to eight XFP repeaters can be connected to any non-networked main panel. GBP 633.78 1
C-Tec XFP385 XFP Flush Mounting Bezel C-Tec XFP385 XFP Flush Mounting BezelAllows XFP 1-2 Loop 32 Zone FirePanels to be semi-flush mounted.Key FeaturesAttractive slimline design.Finished in mild steel.Front face when in situmeasures 456 W x 293 H mm.Hole required to accommodate the bezel and the fire panel is412 W x 255 H x 50 D mm. GBP 32.59 1
C-Tec BF430CF17 FUL Askari 24V Compact Wall Sounder White C-Tec BF430CF17 FUL Askari 24V Compact Wall Sounder WhiteAn Askari Compact Wall Sounder in the colour white. This sounder has 32 tones and is certified to EN54 Part 3 BRE and 13 BSI.Key FeaturesCertified to EN54 Part 3 BRE and 13 BSI97dBA sound output18mA alarm current32 tonesColour White GBP 26.01 1
C-Tec BF430CF16 FUL Askari W Class 24V Compact Wall Sounder Red C-Tec BF430CF16 FUL Askari W Class 24V Compact Wall Sounder RedAn Askari W Class Compact Wall Sounder in the colour red. This sounder has 32 tones and is certified to EN54 Part 3 BRE and 13 BSI.Key FeaturesCertified to EN54 Part 3 BRE and 13 BSI97dBA sound output18mA alarm current32 tones GBP 20.76 1
C-Tec CA433ADR CA Wall Sounder VAD - Deep - Red C-Tec CA433ADR CA Wall Sounder VAD - Deep - RedThe C-Tec CA433ADR is a red wall mounted high outputaddressable wall VAD and sounder with deep base designed for use on C-Tec CASTprotocol analogue addressable fire alarm systems.CAST is the worlds most-advanced distributedintelligence fire alarm system protocol. Conceived designed and realised byC-TEC as part of a five-year multi-million-pound project it involved thecreation of a powerful proprietary communication protocol C-TEC AddressableSystem Technology CAST and multiple control panels field devices.Key FeaturesLPCB certified to EN54-3 17 23 and Kiwa Teleficationcertified to EN54-13Provides W-2.75-9 rated light distribution. Also rated asa W-4-4 VADImpressive 100dBA sound output 1mOnboard short-circuit loop isolator13.5mA typical alarm current 550A typical quiescentcurrent 27-40V DC VAD lit sounder on maxGroup addressing facility allows multiple devices to beoperated simultaneously4 selectable volume levels and 32 selectable tonesIP33C Type B rated GBP 53.41 1
C-Tec CA433ADR65 CA Wall Sounder VAD - Deep Red IP5565 C-Tec CA433ADR65 CA Wall Sounder VAD - Deep Red IP5565The C-Tec CA433ADR65 is a red wall mounted high outputaddressable wall VAD and sounder with deep base designed for use on C-Tec CASTprotocol analogue addressable fire alarm systems.CAST is the worlds most-advanced distributedintelligence fire alarm system protocol. Conceived designed and realised byC-TEC as part of a five-year multi-million-pound project it involved thecreation of a powerful proprietary communication protocol C-TEC AddressableSystem Technology CAST and multiple control panels field devices.Key FeaturesLPCB certified to EN54-3 17 23 and Kiwa Teleficationcertified to EN54-13Provides W-2.75-9 rated light distribution. Also rated asa W-4-4 VADImpressive 100dBA sound output 1mOnboard short-circuit loop isolator13.5mA typical alarm current 550A typical quiescentcurrent 27-40V DC VAD lit sounder on maxGroup addressing facility allows multiple devices to beoperated simultaneously4 selectable volume levels and 32 selectable tonesIP55 Type B rated GBP 64.30 1
C-Tec RXTI2 Hearing Loop Listener C-Tec RXTI2 Hearing Loop ListenerAllows installers and non-hearing aid users to quickly assess the quality and audibility of an induction loop system ideal for daily system checking. The unit also allows non-hearing aid users to listen to the amplified sound generated by hearing loops in theatres cinemas churches etc. bringing performances sermons and general conversation closer to their earsKey FeaturesOn board filters helps reduce mains hum and background noiseIdeal for surveillance museum talk-through and stage manager talk-back systemsRotary onoff and volume control cw soft start functionality3.5mm headphone socket Impedance of headphones not supplied should be no greater than 32 ohmRequires 2 x AAA batteries GBP 72.67 1
C-Tec BF340CTDR 24V C-TEC Loop VID Deep Base - Red C-Tec BF340CTDR 24V C-TEC Loop VID Deep Base - Red The BF340CTDR is a wall mounted addressable flashing beaconunit designed for use with C-Tec XFP analogue addressable fire alarm panelswith the Apollo XP95 Discovery protocols.The C-Tec BF330CTDR has a red body red lens andsupplied with a deep back box ideal for surface cabling. GBP 39.16 1
C-Tec RMF0385401 Bezel C-Tec RMF0385401 BezelSpares are common across the C-Tec range of products. The RMF0385401 is a replacement bezel. GBP 42.42 1
C-Tec RP-YD2-02-C-TEC-CI STI Yellow Manual Call Point With Cover C-Tec RP-YD2-02-C-TEC-CI STI Yellow Manual Call Point With CoverThe RP-YD2-02-C-TEC-CI manufactured by C-Tec is a STI yellowmanual call point with cover. GBP 27.55 1
C-Tec CA460AW CA C Class Base VAD White C-Tec CA460AW CA C Class Base VAD WhiteCAST is the worlds most-advanced distributedintelligence fire alarm system protocol. Conceived designed and realised byC-TEC as part of a five-year multi-million pound project it involved thecreation of a powerful proprietary communication protocol C-TEC AddressableSystem Technology CAST and multiple control panels field devices.Key FeaturesLPCB certified to EN54-23 17 and Kiwa Teleficationcertified to EN54-13Provides C-3-8 rated light distributionOnboard short-circuit loop isolator7mA typical alarm current 460A typical quiescent current 27-40V DCGroup addressing facility allows multiple devices to beoperated simultaneouslyOptional BF330CTLIDW white or BF330CTLIDR red cap availablefor stand-alone useIP21C ratedWhite ceiling fixing plate detector spur wiresincluded GBP 36.53 1
C-Tec AFP711 XFP Network Communications Card C-Tec AFP711 XFP Network Communications CardAn optional system expansion device for use with XFP 12 Loop 32 Zone fire panels. Allowsthe connection of up to eight XFP Repeaters or eight XFP Main panels any mix on an RS485 network. One AFP711 card required per networked Main XFP 12 Loop 32 Zone panel note that XFP510-16 and XFP510-32 repeaters include a network driver card as standard.The AFP711 is NOT compatible with XFP Single Loop 16 Zone panels which require a CFP761 card for networking.Key network protocol features when used for interconnecting XFP main panelsCan be used to connect up to 8 XFP main panels any mix over a two-wire RS485 network of up to 1KM in length.Each networked XFP can be programmed to accept Fires Faults and Control actions such as Silence Alarm Sounders and Control Panel Resets from other panels.Each XFP will accept Disablement commands for zones sounders and output sets from other panels.All panels monitored for network wiring faults.Fires and faults on remote panels are displayed on local panels including the point description.CEs can be programmed into local panels dependent on which remote panel is in alarm.The network supports the programming of site data into remote panels from a PC at a local panel.Time and date is common to all panels.All networked main panels require a network communication card.It is not possible to mix XFP main panels and XFP repeaters on the same network.Key network protocol features when used for connecting XFP repeatersCan be used to connect up to 8 XFP repeaters any mix to one XFP main panel.Up to 500m of cable may be fitted to an XFP two-wire repeater network.Each XFP repeater offers all the functions and controls of an XFP main panel.The XFP main panel must have a network communication card fitted.It is not possible to mix XFP main panels and XFP repeaters on the same network. GBP 114.65 1
C-Tec RNF9826000 ECUSigTel Telephone C-Tec RNF9826000 ECUSigTel Telephone The RNF9826000 manufactured by C-Tec is a replacementtelephone for ECUSigTel disabled refuge system controllers. GBP 12.01 1
C-Tec SAN0422000 QT422RX Accessory Pack C-Tec SAN0422000QT422RX Accessory PackThe SAN0422000 manufactured by C-Tec is an QT422RX accessorypack. GBP 34.56 1
C-Tec SAN0000630 QT630 Accessory Pack C-Tec SAN0000630 QT630 Accessory PackThe SAN0000630 manufactured by C-Tec is a QT630 accessorypack. GBP 6.98 1
C-Tec BF456ACXW Addressable Base VAD Sounder C-3-8 C-Tec BF456ACXW Addressable Base VAD Sounder C-3-8The BF456ACXW C-3-8 Addressable Base VAD Sounder is compatible with C-TECs XFPZFP XP95Discovery Addressable Fire Panels. Its designed to be ceiling mounted - either stand-alone with a red or white cap or as part of a stacked SounderVADDetector Base combination.Key FeaturesThird-party certified to EN54-3 Sounders EN54-23 VADs and 17 Isolators by the LPCBProvides C-3-8 light distribution min 0.4 lux over a 3 x 8m cylindrical areaSupplied with a BF431QCP quick connect plate and detector spur wiresImpressive 96dBA sound output 1mOnboard short-circuit loop isolator550A quiescent current14mA alarm current 24V DC VAD lit sounder on maxGroup addressing facility allows multiple devices to be operated simultaneously7 selectable volume levels and up to 15 selectable tone pairsOptional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone useIP21C ratedPlease note The detector does not come with the base sounder it is shown in the image for illustrative purposes only. GBP 48.60 1
C-Tec BF378M MINIMU Miniature EOL End Of Line For C-Tec EFP amp FP Fire Panels C-Tec BF378M MINIMU Miniature EOL End Of Line For C-Tec EFP FP Fire PanelsThe BF378M is a MINIMU Miniature EOL End of Line for use with the C-Tec EFP and C-Tec FP Fire Alarm Control Panels. GBP 6.50 1