Baldwin Boxall Amplifier Line Monitor with Automatic Amplifier Changeover BVRDACO

Baldwin Boxall Amplifier Line Monitor without Automatic Amplifier Changeover BVRDNCO

Baldwin Boxall VIGIL2 225W Class D Amplifier BV225

Baldwin Boxall VIGIL2 Dual 125W Class D Amplifier BV125D

Baldwin Boxall VIGIL2 Quad 50W Class D Amplifier BV050Q

Baldwin Boxall VIGIL2 Quad 50W Class D Amplifier BV050Q

Baldwin Boxall VIGIL2 Quad 50W Class D Amplifier BV050QThe Vigil2 BV050Q contains four independent 50 Watt Class D Power amplifiers each with one 500 mV balanced input and a 50 Watt 100V Line output. The front panel status indicators show Supply Healthy Overload Over Temperature and Output Level 10 and 100 max output level for each amplifier. The Active Indicator illuminates when the amplifier is not in Sleep Mode. CLASS D amplifiers are 80 efficient therefore reducing unwanted heat dissipation and power input requirements. Rated output power is obtainable using a 22V battery supply.The BV050Q has a Sleep mode automatically reducing the standby current requirement to typically 50mA per amplifier when operating on batteries. Channel gain may be individually set using the potentiometers on the board behind the front panel. The audio inputs to the amplifiers are presented on separate RJ45 connectors each connector providing the balanced audio input and a ground connection. The outputs are presented on 6-way plugscrew termination connectors providing 50V or 100V output. The 24V DC input is presented on a 2-way crimp connected plug and socket. The power output stage of the amplifier is protected against overload conditions i.e. short circuits or abnormal loads etc. Should the amplifier be subjected to an abnormal load the input to the power amplifier is attenuated to a safe level.The amplifiers output voltage is also sensed and should it exceed 100V the input signal will be attenuated ensuring safe operation without creating unnecessary distortion. Over temperature protection is provided using a sensor attached to the output stage heat sink. Should the temperature exceed 90 Degrees Celsius the input signal to will be attenuated to a safe level and the Overtemp LED will be illuminated. If the system is under surveillance it will cause the surveillance detector to indicate a fault condition due to the gain reduction. Up to three BV050Q Amplifier modules may be mounted in one BVMF equipment frame or more normally two amplifier modules and one switched mode power supply charger module.

GBP 1973.16
1

Baldwin Boxall VIGIL3 Dual 300W Class D Amplifier BV300D

Baldwin Boxall VIGIL3 Dual 300W Class D Amplifier BV300D

Baldwin Boxall VIGIL3 Dual 300W Class D Amplifier BV300DThe VIGIL3 amplifiers form part of our new voice alarm range of products. They use new transformerless technology and have many great features. Our VIGIL3 range as with all of our products has been designed and built with quality and absolute reliability in mind.BV300D Dual 300W transformerless class D amplifier. Contains two independent 300W each amplifier has a single balanced line audio input and 300W 100V line output. Can either be used as two independent amplifier modules or two amplifiers wired as an AB dual circuit using a single input signal.Key FeaturesNew floating transformerless technology which negates the need for cumbersome transformers. This means that Each amplifier is considerably lighter - weighing up to 58 less when compared on a Watt-for-Watt basis. Much less copper is required during manufacture.VIGIL3 amplifiers provide increased power in a smaller sized racksystem when compared to alternatives.With VIGIL3 amplifiers it is possible to fit up to 1800 Watts of power in one 2U rack space.Each amplifier unit includes a built-in power supply thus freeing up valuable rack space.The amplifiers have a sleep mode which Operates not only when the system is running on batteries but also when it is running on mains power. Will wake immediately when they are required - there is absolutely no down time. Will benefit users due to the reduction in mains power use - both financially and environmentally.Up to three amplifier units - providing up to 12 zones can be housed in a single 2U rack space.Being modular VIGIL3 amplifiers offer great flexibility for system design.Being backward compatible VIGIL3 amplifiers can replace VIGIL2 equivalents should this be required.VIGIL3 amplifiers when combined with the VIGIL3 battery charger module BVMBC and the BVRD2MBVRD2M4 VIGIL2 voice alarm routers form a powerful EN54 compliant voice alarm system VACIE.

GBP 2413.15
1

Baldwin Boxall VIGIL3 Quad 75W Class D Amplifier BV075Q

Baldwin Boxall VIGIL3 Quad 75W Class D Amplifier BV075Q

Baldwin Boxall VIGIL3 Quad 75W Class D Amplifier BV075QThe VIGIL3 amplifiers form part of our new voice alarm range of products. They use new transformerless technology and have many great features. Our VIGIL3 range as with all of our products has been designed and built with quality and absolute reliability in mind.BV075Q Quad 75W transformerless class D amplifier. Contains four independent 75W each amplifier has a single balanced line audio input and 75W 100V line output. Can either be used as four independent amplifier modules or four amplifiers wired as an AB dual circuit using a single input signal.Key FeaturesNew floating transformerless technology which negates the need for cumbersome transformers. This means that Each amplifier is considerably lighter - weighing up to 58 less when compared on a Watt-for-Watt basis. Much less copper is required during manufacture.VIGIL3 amplifiers provide increased power in a smaller sized racksystem when compared to alternatives.With VIGIL3 amplifiers it is possible to fit up to 1800 Watts of power in one 2U rack space.Each amplifier unit includes a built-in power supply thus freeing up valuable rack space.The amplifiers have a sleep mode which Operates not only when the system is running on batteries but also when it is running on mains power. Will wake immediately when they are required - there is absolutely no down time. Will benefit users due to the reduction in mains power use - both financially and environmentally.Up to three amplifier units - providing up to 12 zones can be housed in a single 2U rack space.Being modular VIGIL3 amplifiers offer great flexibility for system design.Being backward compatible VIGIL3 amplifiers can replace VIGIL2 equivalents should this be required.VIGIL3 amplifiers when combined with the VIGIL3 battery charger module BVMBC and the BVRD2MBVRD2M4 VIGIL2 voice alarm routers form a powerful EN54 compliant voice alarm system VACIE.

GBP 2509.32
1

Baldwin Boxall VIGIL3 Dual 75W Class D Amplifier BV075D

Baldwin Boxall VIGIL3 Dual 75W Class D Amplifier BV075D

Baldwin Boxall VIGIL3 Dual 75W Class D Amplifier BV075DThe VIGIL3 amplifiers form part of our new voice alarm range of products. They use new transformerless technology and have many great features. Our VIGIL3 range as with all of our products has been designed and built with quality and absolute reliability in mind.BV075D Dual 75W transformerless class D amplifier. Contains two independent 75W each amplifier has a single balanced line audio input and 75W 100V line output. Can either be used as two independent amplifier modules or two amplifiers wired as an AB dual circuit using a single input signal.Key FeaturesNew floating transformerless technology which negates the need for cumbersome transformers. This means that Each amplifier is considerably lighter - weighing up to 58 less when compared on a Watt-for-Watt basis. Much less copper is required during manufacture.VIGIL3 amplifiers provide increased power in a smaller sized racksystem when compared to alternatives.With VIGIL3 amplifiers it is possible to fit up to 1800 Watts of power in one 2U rack space.Each amplifier unit includes a built-in power supply thus freeing up valuable rack space.The amplifiers have a sleep mode which Operates not only when the system is running on batteries but also when it is running on mains power. Will wake immediately when they are required - there is absolutely no down time. Will benefit users due to the reduction in mains power use - both financially and environmentally.Up to three amplifier units - providing up to 12 zones can be housed in a single 2U rack space.Being modular VIGIL3 amplifiers offer great flexibility for system design.Being backward compatible VIGIL3 amplifiers can replace VIGIL2 equivalents should this be required.VIGIL3 amplifiers when combined with the VIGIL3 battery charger module BVMBC and the BVRD2MBVRD2M4 VIGIL2 voice alarm routers form a powerful EN54 compliant voice alarm system VACIE.

GBP 1532.26
1

Baldwin Boxall VIGIL3 Quad 150W Class D Amplifier BV150Q

Baldwin Boxall VIGIL3 Quad 150W Class D Amplifier BV150Q

Baldwin Boxall VIGIL3 Quad 150W Class D Amplifier BV150QThe VIGIL3 amplifiers form part of our new voice alarm range of products. They use new transformerless technology and have many great features. Our VIGIL3 range as with all of our products has been designed and built with quality and absolute reliability in mind.BV150Q Quad 150W transformerless class D amplifier. Contains four independent 150W each amplifier has a single balanced line audio input and 150W 100V line output. Can either be used as four independent amplifier modules or four amplifiers wired as an AB dual circuit using a single input signal.Key FeaturesNew floating transformerless technology which negates the need for cumbersome transformers. This means that Each amplifier is considerably lighter - weighing up to 58 less when compared on a Watt-for-Watt basis. Much less copper is required during manufacture.VIGIL3 amplifiers provide increased power in a smaller sized racksystem when compared to alternatives.With VIGIL3 amplifiers it is possible to fit up to 1800 Watts of power in one 2U rack space.Each amplifier unit includes a built-in power supply thus freeing up valuable rack space.The amplifiers have a sleep mode which Operates not only when the system is running on batteries but also when it is running on mains power. Will wake immediately when they are required - there is absolutely no down time. Will benefit users due to the reduction in mains power use - both financially and environmentally.Up to three amplifier units - providing up to 12 zones can be housed in a single 2U rack space.Being modular VIGIL3 amplifiers offer great flexibility for system design.Being backward compatible VIGIL3 amplifiers can replace VIGIL2 equivalents should this be required.VIGIL3 amplifiers when combined with the VIGIL3 battery charger module BVMBC and the BVRD2MBVRD2M4 VIGIL2 voice alarm routers form a powerful EN54 compliant voice alarm system VACIE.

GBP 2944.78
1

Baldwin Boxall VIGIL3 Dual 150W Class D Amplifier BV150D

Baldwin Boxall VIGIL3 Dual 150W Class D Amplifier BV150D

Baldwin Boxall VIGIL3 Dual 150W Class D Amplifier BV150DThe VIGIL3 amplifiers form part of our new voice alarm range of products. They use new transformerless technology and have many great features. Our VIGIL3 range as with all of our products has been designed and built with quality and absolute reliability in mind.BV150D Contains two independent 150W each amplifier has a single balanced line audio input and 150W 100V line output. Can either be used as two independent amplifier modules or two amplifiers wired as an AB dual circuit using a single input signal.Key FeaturesNew floating transformerless technology which negates the need for cumbersome transformers. This means that Each amplifier is considerably lighter - weighing up to 58 less when compared on a Watt-for-Watt basis. Much less copper is required during manufacture.VIGIL3 amplifiers provide increased power in a smaller sized racksystem when compared to alternatives.With VIGIL3 amplifiers it is possible to fit up to 1800 Watts of power in one 2U rack space.Each amplifier unit includes a built-in power supply thus freeing up valuable rack space.The amplifiers have a sleep mode which Operates not only when the system is running on batteries but also when it is running on mains power. Will wake immediately when they are required - there is absolutely no down time. Will benefit users due to the reduction in mains power use - both financially and environmentally.Up to three amplifier units - providing up to 12 zones can be housed in a single 2U rack space.Being modular VIGIL3 amplifiers offer great flexibility for system design.Being backward compatible VIGIL3 amplifiers can replace VIGIL2 equivalents should this be required.VIGIL3 amplifiers when combined with the VIGIL3 battery charger module BVMBC and the BVRD2MBVRD2M4 VIGIL2 voice alarm routers form a powerful EN54 compliant voice alarm system VACIE.

GBP 1787.18
1

Baldwin Boxall DC Line Monitor BVRDADC

Baldwin Boxall DC Line Monitor BVRDADC

Baldwin Boxall DC Line Monitor BVRDADCThe Vigil BVRDADC is a loudspeaker line monitor and amplifier changeover unit for use with VIGIL amplifiers and the BVRD2M router. Each unit is supplied as a DIN rail-mounting module with screw terminals for connections to the amplifiers and loudspeaker lines. Connection to the BVRD2M is by CAN BUS ports. Each unit consists of ten channels that can be utilised for either dual or single circuit systems.For dual circuits ten working amplifiers five dual circuits and one standby amplifier can be accommodated. For single circuit systems ten working amplifiers ten single circuits and one standby amplifier are available. If an amplifier were to fail the BVRDADC automatically detects the faulty amplifier and switches over to a reserve amplifier until the fault has been rectified. A fault will be displayed on the BVRD2M front panel and also stored in the BVRD2M fault log.When the faulty amplifier has been replaced it is necessary to press the Fault Reset button on the front of the BVRD2M to restore the system and stop using the reserve amplifier. Each loudspeaker line including spurs must have an End of Line resistor fitted in parallel with the last physical loudspeaker on the line. All loudspeakers must be fitted with a DC Blocking capacitor. The BVRDADC monitors the integrity of the Loudspeaker Line by measuring a small DC current flowing through the End of Line resistors. Any change in this current indicates either a short circuit or open circuit condition on the loudspeaker line. Earth faults are also detected.

GBP 1449.71
1

Baldwin Boxall BV3MDP10F Vigil 3 10 Way Mains Distribution with Fans

Baldwin Boxall BV3MDP05F Vigil 3 5 Way Mains Distribution with Fans

Baldwin Boxall BV3ADIS VIGIL 3 Slave DC Line Monitoring IsolatorChangeover Mod

Baldwin Boxall ECLIPSE 4 CASE BATT BOX BVECASE4BATT

Baldwin Boxall Line Vox Unit BT10

Baldwin Boxall BV3ADIM Vigil 3 Line Monitoring IsolatorCover Mod

Baldwin Boxall VIGIL3 Battery Charger Module BVMBC

Baldwin Boxall 100W Volume Controls with Override Relay BVC100

Baldwin Boxall 6W Volume Controls with Override Relay BVC6

Baldwin Boxall Impedance Monitor BVLAM

Baldwin Boxall Impedance Monitor BVLAM

Baldwin Boxall Impedance Monitor BVLAMThe BVLAM provides 8 zone 100V line relay switching loudspeaker zone selection from 1 amplifier.It incorporates impedance monitoring on all 8 loudspeaker lines when the zone is not selected. If the load increases impedance decreases the appropriate fault LED illuminates steady and if the load decreases impedance increases the fault LED will flash.The impedance changes for a fault to be detected is selected to either 20 or 40 using the mode DIL switch 8. If the impedance falls to approximately 50 of its original value the line is considered to be short circuit and will not be selected to the amplifier.All 8 zone select inputs will access when it is between 2 to 6.5V. An open circuit access input above 15V will be indicated by the appropriate fault LED flashing and a short circuit access input below 2V by the fault LED illuminating steady.Under all fault conditions the OK LED will extinguish and the common fault relay volt-free contacts to change state.Key FeaturesRack-mountable unit 1U high. Two units can be mounted across one rack shelf.Provides eight loudspeaker zone selection from one amplifier.On receipt of a signal from an input ie zone selecting microphone the BVLAM triggers the amplifier to output to the selected zone.An internal relay enables zone switching.The BVLAM provides constant impedance monitoring on each of the eight loudspeaker circuits when not selected.LEDs are used to indicate a drop or increase in impedance - set at either 20 or 40 by DIL switches.Note due to detection accuracy BVLAM is only suitable for BS5839-8 voice alarm systems with less than five speakers per circuit.Access faults on any of the zones from the microphone are indicated by LEDs on the BVLAM.Additional LED indicators are provided to show system healthy and supply healthy.The Baldwin Boxall Impedance Monitor BVLAM provides a combination of zones relay switches from one amplifier. It changes if a fault is detected.

GBP 880.90
1