Apollo Discovery Marine Waterproof Manual Call Point with Isolator 58100-976MAR Apollo Discovery Marine Waterproof Manual Call Point with Isolator 58100-976MARThe Discovery Marine Manual Call Point has been approved for use in outdoor marine applications. A seven-segment DIL switch enables addressing of each call point at commissioning stage. When operated the manual call point interrupts the polling cycle for a fast response. Bi-coloured LEDs indicate isolate and normal conditions.OperationThe Discovery Marine Waterproof Manual Call Point MCP is based on the KAC conventional MCP range. It is electronically and mechanically compatible with previous Apollo call points based on KACs World Series product. The address of each call point is set at the commissioning stage by means of a seven-segment DIL switch. If a MCP is activated it interrupts the normal protocol to give a fast response.Key FeaturesPlug and Play terminal connections for fast wiringContinuity link for wiring test before commissioningReports an alarm in under 0.2 secondsResettable element GBP 252.16 1
Apollo Discovery Marine Manual Call Point with Isolator 58100-971MAR Apollo Discovery Marine Manual Call Point with Isolator 58100-971MARThe Discovery Marine Manual Call Point has been approved for use in indoor marine applications. A seven-segment DIL switch enables addressing of each call point at commissioning stage. When operated the manual call point interrupts the polling cycle for a fast response. Bi-coloured LEDs indicate isolate and normal conditions.OperationThe Discovery Marine Manual Call Point MCP is based on the KAC conventional MCP range. It is electronically and mechanically compatible with previous Apollo call points based on KACs World Series product. The address of each call point is set at the commissioning stage by means of a seven-segment DIL switch. If a MCP is activated it interrupts the normal protocol to give a fast response.Key FeaturesFlashing LED option to indicate polling Discovery systems onlyPlug and Play terminal connections for fast wiringContinuity link for wiring test before commissioningReports an alarm in under 0.2 secondsResettable element GBP 99.68 1
Apollo Weatherproof Manual Call Point Red 58100-950APO Apollo Weatherproof Manual Call Point Red 58100-950APOThe Apollo Waterproof Manual Call Point has been designed for use outdoors and in places where moisture can occur. A seven-segment DIL switch enables addressing of each call point at commissioning stage. When operated the Manual Call Point interrupts the polling cycle for a fast response. Bi-coloured LEDs indicate isolate and normal conditions.Key FeaturesIP 67 ratedPlug and play terminal connections for fast wiringContinuity link for wiring test before commissioningReports an alarm in under 0.2 secondsResettable element GBP 168.37 1
Apollo Weatherproof Manual Call Point with Isolator Red 58100-951APO Apollo Weatherproof Manual Call Point with Isolator Red 58100-951APOThe Apollo Waterproof Manual Call Point has been designed for use outdoors and in places where moisture can occur. A seven-segment DIL switch enables addressing of each call point at commissioning stage. When operated the Manual Call Point interrupts the polling cycle for a fast response. Bi-coloured LEDs indicate isolate and normal conditions.Key FeaturesIP 67 ratedPlug and play terminal connections for fast wiringContinuity link for wiring test before commissioningReports an alarm in under 0.2 secondsResettable element GBP 236.18 1
Apollo Discovery Manual Call Point with Isolator 58100-908APO Apollo Discovery Manual Call Point with Isolator 58100-908APOA seven-segment DIL switch enables addressing of each call point at commissioning stage. When operated the manual call point interrupts the polling cycle for a fast response. Bi-coloured LEDs indicate isolate and normal conditions.Discovery is a range of high-specification analogue addressable fire detectors and alarm devices. Discovery detectors offer effective false alarm management by a combination of EN 54 approved operating modes and sophisticated algorithms.Key FeaturesPlug and Play terminal connections for fast wiringContinuity link for wiring test before commissioningReports an alarm in under 0.2 secondsResettable element GBP 53.12 1
Apollo XPA-CB-14027-APO XPander Multisensor Detector with Sounder VID Base White Flash Apollo XPA-CB-14027-APO XPander Multisensor Detector with Sounder VID Base White FlashXPander sounders are ceiling mounted and use a bi-directional monitored radio platform to communicate.They feature 4 tone pairs including the Apollo tone and a self-test which causes a fault signal to be sent if the sounders fail to operate. The address of a sounder or a combined soundervisual indicator is set at the commissioning stage by means of a DIL switch.The sounder address is plus one of the address set. The sounders and combined soundervisual indicators are powered by two packs of batteries one with three AA and one with three C size alkaline batteries which provide a working life of typically 3-5 years.The five-year life includes weekly tests and a half-hour sounding in a fire condition. The Combined Sounders and Sounder Visual Indicators incorporate audible and visual alarm indicators within one unit. GBP 363.00 1
Apollo XPA-CB-14023-APO XPander Multisensor Detector with Sounder VID Base Red Flash Apollo XPA-CB-14023-APO XPander Multisensor Detector with Sounder VID Base Red FlashXPander sounders are ceiling mounted and use a bi-directional monitored radio platform to communicate. They feature 4 tone pairs including the Apollo tone and a self-test which causes a fault signal to be sent if the sounders fail to operate.The address of a sounder or a combined soundervisual indicator is set at the commissioning stage by means of a DIL switch. The sounder address is plus one of the address set.The sounders and combined soundervisual indicators are powered by two packs of batteries one with three AA and one with three C size alkaline batteries which provide a working life of typically 3-5 years.The five-year life includes weekly tests and a half-hour sounding in a fire condition. The Combined Sounders and Sounder Visual Indicators incorporate audible and visual alarm indicators within one unit. GBP 363.00 1
Apollo XPA-CB-14019-APO XPander Multisensor Detector with Sounder Base Apollo XPA-CB-14019-APO XPander Multisensor Detector with Sounder BaseXPander sounders are ceiling mounted and use a bi-directional monitored radio platform to communicate. They feature 4 tone pairs including the Apollo tone and a self-test which causes a fault signal to be sent if the sounders fail to operate.The address of a sounder or a combined soundervisual indicator is set at the commissioning stage by means of a DIL switch.The sounder address is plus one of the address set. The sounders and combined soundervisual indicators are powered by two packs of batteries one with three AA and one with three C size alkaline batteries which provide a working life of typically 3-5 years.The five-year life includes weekly tests and a half-hour sounding in a fire condition. The Combined Sounders and Sounder Visual Indicators incorporate audible and visual alarm indicators within one unit. GBP 327.13 1
Apollo Orbis A2S Heat Detector with Flashing LED ORB-HT-11014-APO Apollo Orbis A2S Heat Detector with Flashing LED ORB-HT-11014-APOThe Orbis Heat Detector monitors temperature by using a single thermistor which provides a voltage output proportional to the external air temperature.OperationOrbis heat detectors have an open-web casing which allows air to flow freely across a thermistor which measures the air temperature every 2 seconds. A microprocessor stores the temperatures and compares them with pre-set values to determine whether a fixed upper limitthe alarm levelhas been reached. In the case of rate-of-rise detectors the microprocessor uses algorithms to determine how fast the temperature is increasing. Static heat detectors respond only when a fixed temperature has been reached. Rate-of-rise detectors also have a fixed upper limit but they also measure the rate of increase in temperature. A fire might thus be detected at an earlier stage than with a static detector so that a rate-of-rise detector is to be preferred to a static heat detector unless sharp increases of heat are part of the normal environment in the area protected by the heat detector. GBP 14.72 1
Apollo Orbis CR Heat Detector with Flashing LED ORB-HT-11017-APO Apollo Orbis CR Heat Detector with Flashing LED ORB-HT-11017-APOThe Orbis Heat Detector monitors temperature by using a single thermistor which provides a voltage output proportional to the external air temperature.OperationOrbis heat detectors have an open-web casing which allows air to flow freely across a thermistor which measures the air temperature every 2 seconds. A microprocessor stores the temperatures and compares them with pre-set values to determine whether a fixed upper limitthe alarm levelhas been reached. In the case of rate-of-rise detectors the microprocessor uses algorithms to determine how fast the temperature is increasing. Static heat detectors respond only when a fixed temperature has been reached. Rate-of-rise detectors also have a fixed upper limit but they also measure the rate of increase in temperature. A fire might thus be detected at an earlier stage than with a static detector so that a rate-of-rise detector is to be preferred to a static heat detector unless sharp increases of heat are part of the normal environment in the area protected by the heat detector. GBP 15.80 1
Apollo Orbis CS Heat Detector with Flashing LED ORB-HT-11018-APO Apollo Orbis CS Heat Detector with Flashing LED ORB-HT-11018-APOThe Orbis Heat Detector monitors temperature by using a single thermistor which provides a voltage output proportional to the external air temperature.OperationOrbis heat detectors have an open-web casing which allows air to flow freely across a thermistor which measures the air temperature every 2 seconds. A microprocessor stores the temperatures and compares them with pre-set values to determine whether a fixed upper limitthe alarm levelhas been reached. In the case of rate-of-rise detectors the microprocessor uses algorithms to determine how fast the temperature is increasing. Static heat detectors respond only when a fixed temperature has been reached. Rate-of-rise detectors also have a fixed upper limit but they also measure the rate of increase in temperature. A fire might thus be detected at an earlier stage than with a static detector so that a rate-of-rise detector is to be preferred to a static heat detector unless sharp increases of heat are part of the normal environment in the area protected by the heat detector. GBP 15.80 1
Apollo Orbis A1R Heat Detector with Flashing LED ORB-HT-11013-APO Apollo Orbis A1R Heat Detector with Flashing LED ORB-HT-11013-APOThe Orbis Heat Detector monitors temperature by using a single thermistor which provides a voltage output proportional to the external air temperature.OperationOrbis heat detectors have an open-web casing which allows air to flow freely across a thermistor which measures the air temperature every 2 seconds. A microprocessor stores the temperatures and compares them with pre-set values to determine whether a fixed upper limitthe alarm levelhas been reached. In the case of rate-of-rise detectors the microprocessor uses algorithms to determine how fast the temperature is increasing. Static heat detectors respond only when a fixed temperature has been reached. Rate-of-rise detectors also have a fixed upper limit but they also measure the rate of increase in temperature. A fire might thus be detected at an earlier stage than with a static detector so that a rate-of-rise detector is to be preferred to a static heat detector unless sharp increases of heat are part of the normal environment in the area protected by the heat detector. GBP 14.72 1
Apollo Orbis A1S Heat Detector with Flashing LED ORB-HT-11167-APO Apollo Orbis A1S Heat Detector with Flashing LED ORB-HT-11167-APOThe Orbis Heat Detector monitors temperature by using a single thermistor which provides a voltage output proportional to the external air temperature.OperationOrbis heat detectors have an open-web casing which allows air to flow freely across a thermistor which measures the air temperature every 2 seconds. A microprocessor stores the temperatures and compares them with pre-set values to determine whether a fixed upper limitthe alarm levelhas been reached. In the case of rate-of-rise detectors the microprocessor uses algorithms to determine how fast the temperature is increasing. Static heat detectors respond only when a fixed temperature has been reached. Rate-of-rise detectors also have a fixed upper limit but they also measure the rate of increase in temperature. A fire might thus be detected at an earlier stage than with a static detector so that a rate-of-rise detector is to be preferred to a static heat detector unless sharp increases of heat are part of the normal environment in the area protected by the heat detector. GBP 14.72 1
Apollo Orbis BR Heat Detector with Flashing LED ORB-HT-11015-APO Apollo Orbis BR Heat Detector with Flashing LED ORB-HT-11015-APOThe Orbis Heat Detector monitors temperature by using a single thermistor which provides a voltage output proportional to the external air temperature.OperationOrbis heat detectors have an open-web casing which allows air to flow freely across a thermistor which measures the air temperature every 2 seconds. A microprocessor stores the temperatures and compares them with pre-set values to determine whether a fixed upper limitthe alarm levelhas been reached. In the case of rate-of-rise detectors the microprocessor uses algorithms to determine how fast the temperature is increasing. Static heat detectors respond only when a fixed temperature has been reached. Rate-of-rise detectors also have a fixed upper limit but they also measure the rate of increase in temperature. A fire might thus be detected at an earlier stage than with a static detector so that a rate-of-rise detector is to be preferred to a static heat detector unless sharp increases of heat are part of the normal environment in the area protected by the heat detector. GBP 15.80 1
Apollo XPander 868MHz Diversity Survey Kit XPA-TE-14075-APO Apollo XPander 868MHz Diversity Survey Kit XPA-TE-14075-APOThe XPander Diversity Survey kit is used at the site survey stage to ascertain if a site is suitable for an XPander installation. A site survey must be carried out before XPander can be installed. The Diversity Survey Kit is compliant to BS 5839-1.Brand InformationXPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. It communicates with the control panel using the Apollo addressable two-wire power and communications system. The interface communicates with the detection and alarm signalling devices by means of radio waves.The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface. The detectors incorporate drift compensation and report any compensation limit occurring. The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.Key FeaturesIndicates the suitability of proposed device location GBP 369.71 1
Apollo Waterproof Addressable Manual Call Point 58200-951APO Apollo Waterproof Addressable Manual Call Point 58200-951APOThe Apollo Waterproof Manual Call Point has a highly visible alarm indicator which can be seen from up to 10 metres away. The manual call point interrupts the polling cycle for a fast response when activated. A combined LED indicator and front reset mechanism allows for a simple reset.OperationThe address of each Manual Call Point is set at the commissioning stage by means of a seven-segment DIL switch. A red alarm LED is provided on the Manual Call Point. This LED is controlled independently of the Manual Call Point by the fire control panel.Once activated the Manual Call Point can be reset by inserting the reset key into the front facing LED turning clockwise until a positive click and reset occurs. The isolated version of the Manual Call Point incorporates a short circuit isolator which will ensure its operation in the event of a short circuit fault on the loop. Isolator operation is indicated by a yellow LED.Key FeaturesIP67 ratedEN54-11 approved EN54-17 approved for Isolator versionE-Z fit connectorsFront facing addressing without the need to detach the backboxA unique ergonomically designed key for resetting and front cover removal GBP 112.84 1
Apollo XP95 Manual Call Point without Isolator - 55100-905APO Apollo XP95 Manual Call Point without Isolator - 55100-905APOA seven-segment DIL switch enables the addressing of each call point at commissioning stage. When operated the manual call point interrupts the polling cycle for a fast response. Bi-coloured LEDs indicate isolate and normal conditions.The XP95 range of analogue addressable fire detectors uses tried and trusted technology to give the best performance and has unique features that benefit the installer and the end user. It is suitable for medium-to-large applications with simple installation requirements.As it operates using digital communication XP95 has a high immunity from corruption and is therefore often preferred in a large system where life safety is critical. XP95 products are frequently used in commercial industrial financial government ITtelecoms and healthcare applications.The choice of detector from the XP95 range follows the well-established principles of system design. The optimum detector type will depend on the type of fire riskfire load and the type of environment in which the detector is sited. For general use smoke detectors are recommended since these give the highest level of protection.Key FeaturesPlug and Play terminal connections for fast wiringContinuity link for wiring test before commissioningReports an alarm in under 0.2 secondsResettable element GBP 55.27 1
Apollo Marine Orbis A1R Heat Detector - ORB-HT-41001-MAR Apollo Marine Orbis A1R Heat Detector - ORB-HT-41001-MARThe Orbis Marine Heat Detector uses a single thermistor to sense the air temperature around the detector. There are twelve heat detectors in the Orbis Marine range designed to suit a wide variety of operating conditions.OperationOrbis heat detectors have an open-web casing which allows air to flow freely across a thermistor which measures the air temperature every 2 seconds. A microprocessor stores the temperatures and compares them with pre-set values to determine whether a fixed upper limit the alarm level has been reached. In the case of rate-of-rise detectors the microprocessor uses algorithms to determine how fast the temperature is increasing.Static heat detectors respond only when a fixed temperature has been reached. Rate-of-rise detectors also have a fixed upper limit but they also measure the rate of increase in temperature. A fire might thus be detected at an earlier stage than with a static detector so that a rate-of-rise detector is to be preferred to a static heat detector unless sharp increases of heat are part of the normal environment in the area protected by the heat detector.Key FeaturesCan be used for applications where smoke detectors are unsuitableIdeal for environments that are dirty or smoky under normal conditions GBP 19.97 1
Apollo Marine Orbis BR Heat Detector - ORB-HT-41003-MAR Apollo Marine Orbis BR Heat Detector - ORB-HT-41003-MARThe Orbis Marine Heat Detector uses a single thermistor to sense the air temperature around the detector. There are twelve heat detectors in the Orbis Marine range designed to suit a wide variety of operating conditions.OperationOrbis heat detectors have an open-web casing which allows air to flow freely across a thermistor which measures the air temperature every 2 seconds. A microprocessor stores the temperatures and compares them with pre-set values to determine whether a fixed upper limit the alarm level has been reached. In the case of rate-of-rise detectors the microprocessor uses algorithms to determine how fast the temperature is increasing.Static heat detectors respond only when a fixed temperature has been reached. Rate-of-rise detectors also have a fixed upper limit but they also measure the rate of increase in temperature. A fire might thus be detected at an earlier stage than with a static detector so that a rate-of-rise detector is to be preferred to a static heat detector unless sharp increases of heat are part of the normal environment in the area protected by the heat detector.Key FeaturesCan be used for applications where smoke detectors are unsuitableIdeal for environments that are dirty or smoky under normal conditions GBP 20.99 1
Apollo Discovery Weatherproof Yellow Manual Call Point with Isolator 58100-953APO Apollo Discovery Weatherproof Yellow Manual Call Point with Isolator 58100-953APOThe Waterproof Manual Call Point has been designed for use outdoors and in places where moisture can occur. A seven-segment DIL switch enables addressing of each call point at commissioning stage. When operated the manual call point interrupts the polling cycle for a fast response. Bi-coloured LEDs indicate isolate and normal conditions.OperationThe Apollo Discovery Waterproof Manual Call Point has been designed to operate on a loop of intelligent fire detection devices. An alarm is initiated by pressing the resettable element. The manual call point signals to the control and indicating equipment using an interrupt feature within the Apollo digital communication protocol. An alarm status is indicated by a yellow and black bar in the lower section of the resettable element and a red LED. The manual call point can be easily reset from the front using the supplied reset key.Brand InformationDiscovery is a range of high-specification analogue addressable fire detectors and alarm devices. Discovery detectors offer effective false alarm management by a combination of EN 54 approved operating modes and sophisticated algorithms.Key FeaturesPlug and Play terminal connections for fast wiringContinuity link for wiring test before commissioningReports an alarm in under 0.2 secondsResettable element GBP 155.15 1
Apollo Marine Orbis A2S Heat Detector - ORB-HT-41002-MAR Apollo Marine Orbis A2S Heat Detector - ORB-HT-41002-MARThe Orbis Marine Heat Detector uses a single thermistor to sense the air temperature around the detector. There are twelve heat detectors in the Orbis Marine range designed to suit a wide variety of operating conditions.OperationOrbis heat detectors have an open-web casing which allows air to flow freely across a thermistor which measures the air temperature every 2 seconds. A microprocessor stores the temperatures and compares them with pre-set values to determine whether a fixed upper limit the alarm level has been reached. In the case of rate-of-rise detectors the microprocessor uses algorithms to determine how fast the temperature is increasing.Static heat detectors respond only when a fixed temperature has been reached. Rate-of-rise detectors also have a fixed upper limit but they also measure the rate of increase in temperature. A fire might thus be detected at an earlier stage than with a static detector so that a rate-of-rise detector is to be preferred to a static heat detector unless sharp increases of heat are part of the normal environment in the area protected by the heat detector.Key FeaturesCan be used for applications where smoke detectors are unsuitableIdeal for environments that are dirty or smoky under normal conditions GBP 19.97 1
Apollo Marine Orbis CR Heat Detector - ORB-HT-41005-MAR Apollo Marine Orbis CR Heat Detector - ORB-HT-41005-MARThe Orbis Marine Heat Detector uses a single thermistor to sense the air temperature around the detector. There are twelve heat detectors in the Orbis Marine range designed to suit a wide variety of operating conditions.OperationOrbis heat detectors have an open-web casing which allows air to flow freely across a thermistor which measures the air temperature every 2 seconds. A microprocessor stores the temperatures and compares them with pre-set values to determine whether a fixed upper limit the alarm level has been reached. In the case of rate-of-rise detectors the microprocessor uses algorithms to determine how fast the temperature is increasing.Static heat detectors respond only when a fixed temperature has been reached. Rate-of-rise detectors also have a fixed upper limit but they also measure the rate of increase in temperature. A fire might thus be detected at an earlier stage than with a static detector so that a rate-of-rise detector is to be preferred to a static heat detector unless sharp increases of heat are part of the normal environment in the area protected by the heat detector.Key FeaturesCan be used for applications where smoke detectors are unsuitableIdeal for environments that are dirty or smoky under normal conditions GBP 20.99 1
Apollo Orbis Marine CS Heat Detector with Flashing LED ORB-HT-41018-MAR Apollo Orbis Marine CS Heat Detector with Flashing LED ORB-HT-41018-MARThe Orbis Marine Heat Detector uses a single thermistor to sense the air temperature around the detector. There are twelve heat detectors in the Orbis Marine range designed to suit a wide variety of operating conditions.OperationOrbis heat detectors have an open-web casing which allows air to flow freely across a thermistor which measures the air temperature every 2 seconds. A microprocessor stores the temperatures and compares them with pre-set values to determine whether a fixed upper limit the alarm level has been reached. In the case of rate-of-rise detectors the microprocessor uses algorithms to determine how fast the temperature is increasing.Static heat detectors respond only when a fixed temperature has been reached. Rate-of-rise detectors also have a fixed upper limit but they also measure the rate of increase in temperature. A fire might thus be detected at an earlier stage than with a static detector so that a rate-of-rise detector is to be preferred to a static heat detector unless sharp increases of heat are part of the normal environment in the area protected by the heat detector.Key FeaturesCan be used for applications where smoke detectors are unsuitableIdeal for environments that are dirty or smoky under normal conditionsFlashing LED option GBP 20.99 1
Apollo Orbis I.S. A1R Heat Detector with Flashing LED ORB-HT-51146-APO Apollo Orbis I.S. A1R Heat Detector with Flashing LED ORB-HT-51146-APOThe Orbis IS Heat Detector monitors temperature by using a single thermistor network which provides a voltage output proportional to the external air temperature. The Orbis IS range incorporates seven heat detector classes to suit a wide range of operating conditions.OperationOrbis I.S. heat detectors have an open-web casing which allows air to flow freely across a thermistor which measures the air temperature every 2 seconds. A microprocessor stores the temperature and compares them with per-set values to determine whether a fixed upper limit - the alarm limit - has been reached. In the case of rate-of-rise detectors the microprocessor uses algorithms to determine how fast the temperature is increasing.Static heat detectors respond only when a fixed temperature has been reached. Rate-of-rise detectors have a fixed upper limit but they also measure the rate of increase in temperature. A fire might thus be detected at an earlier stage then with a static detector so that a rate-of-rise detector is to be preferred to a static heat detector unless sharp increases of heat are part of the normal environment in the area protected by the heat detector.Key FeaturesCan be used for applications where smoke detectors are unsuitableIdeal for environments that are dirty or smoky under normal conditionsReduced incidences of false alarmsIncreased reliability of detection GBP 77.36 1
Apollo Discovery Marine Manual Call Point 58100-970MAR Apollo Discovery Marine Manual Call Point 58100-970MARThe Discovery Marine Manual Call Point MCP is based on the KAC conventional MCP range. It is electronically and mechanically compatible with previous Apollo call points based on KACs World Series product. The address of each call point is set at the commissioning stage by means of a seven-segment DIL switch.If an MCP is activated it interrupts the normal protocol to give a fast response. A single bi-coloured alarm LED is provided on the manual call point. This LED is controlled independently of the call point by the control panel and may be set to flash each time the call point is polled. The red LED is illuminated when the call point has been activated and sent into alarm.On the isolated versions an amberyellow LED indicates a short-circuit on the loop wiring either side of the call point. Call points can be remotely tested from the panel by transmission of a single bit in the communications protocol. Call points respond by providing a value of 64 which corresponds to the alarm value. The panel should recognise this response as a test signal and should not raise a general alarm.Key FeaturesFlashing LED option to indicate polling Discovery systems onlyPlug and Play terminal connections for fast wiringContinuity link for wiring test before commissioningReports an alarm in under 0.2 secondsResettable element GBP 78.71 1